Initial ratio optimization for the ejector cooling system with thermal pumping effect (ECSTPE)

Abstract An ejector cooling system with thermal pumping effect (ECSTPE) could operate without consumption of electric power, but it discards a great amount of thermal energy, which generally results in a lower COP value and a greater chilling load. An innovative concept for the optimal initial ratio is therefore proposed to develop the optimal time length of cooling stage (TLCS) control method. The optimal TLCS control method effectively improves the ECSTPE performance. First, in this context, it was theoretically proven that the optimal initial ratio could be used to reduce the energy loss and the chilling load. Second, it was formulated how to achieve the optimal initial ratio; and the optimal TLCS control method was determined by identifying the relationship between the TLCS and the initial ratio. Third, case studies were conducted to demonstrate the effectiveness of the developed optimal TLCS control method on ECSTPEs with different refrigerants. The results showed that for ECSTPE with R134a, a 10-second deviation from the optimal TLCS led to a decrease of 5.6% in the COP value and an increase of 23.7% in the chilling load. For ECSTPEs with R141b and R365mfc, a 10-second deviation led to relatively slight performance deterioration; however, an excessive deviation (e.g., 100 s) would lead to severe performance deterioration (e.g., increases of 35% and 58% in the chilling loads for ECSTPEs with R134b and R365mfc, respectively). The developed optimal TLCS control method could certainly improve the performance of ECSTPEs with other refrigerants.

[1]  K. Cizungu,et al.  Performance comparison of vapour jet refrigeration system with environment friendly working fluids , 2001 .

[2]  A. Khalil,et al.  Ejector design and theoretical study of R134a ejector refrigeration cycle , 2011 .

[3]  Kamaruzzaman Sopian,et al.  Performance enhancement of ejector–absorption cooling cycle by re-arrangement of solution streamlines and adding RHE , 2015 .

[4]  Bin-Juine Huang,et al.  Ejector Performance Characteristics and Design Analysis of Jet Refrigeration System , 1985 .

[5]  Khaled M. Bataineh,et al.  Optimization analysis of solar thermal water pump , 2016 .

[6]  Bourhan Tashtoush,et al.  Performance study of ejector cooling cycle at critical mode under superheated primary flow , 2015 .

[7]  Elias B. Kosmatopoulos,et al.  A roadmap towards intelligent net zero- and positive-energy buildings , 2011 .

[8]  Satha Aphornratana,et al.  A circulating system for a steam jet refrigeration system , 2005 .

[9]  A. Selvaraju,et al.  Analysis of an ejector with environment friendly refrigerants , 2004 .

[10]  Shengqiang Shen,et al.  A novel solar bi-ejector refrigeration system and the performance of the added injector with different structures and operation parameters , 2009 .

[11]  Jacek Kasperski,et al.  Efficiency analysis of alternative refrigerants for ejector cooling cycles , 2015 .

[12]  Jacek Kasperski Two kinds of gravitational ejector refrigerator stimulation , 2009 .

[13]  K. Sumathy,et al.  Solar thermal water pumping systems: a review , 1999 .

[14]  Kamaruzzaman Sopian,et al.  Review on solar-driven ejector refrigeration technologies , 2009 .

[15]  Mohammed R. Ahmed,et al.  Experimental and computational studies on a steam jet refrigeration system with constant area and variable area ejectors , 2014 .

[16]  Per Lundqvist,et al.  An exergy analysis of a solar-driven ejector refrigeration system , 2004 .

[17]  Yu Wang,et al.  HVAC system design under peak load prediction uncertainty using multiple-criterion decision making technique , 2015 .

[18]  Jacek Kasperski Rotational type of a gravitational ejector refrigerator – A system balance of the refrigerant analysis , 2010 .

[19]  Saffa Riffat,et al.  A novel heat pipe/ejector cooler , 1998 .

[20]  Fabio Inzoli,et al.  Ejector refrigeration: A comprehensive review , 2016 .

[21]  Guangming Chen,et al.  Ejector Performance of a Pump-less Ejector Refrigeration System Driven by Solar Thermal Energy , 2012 .

[22]  Satha Aphornratana,et al.  Ejectors: applications in refrigeration technology , 2004 .

[23]  K. Sumathy,et al.  Thermodynamic analysis and optimization of a solar thermal water pump , 2001 .

[24]  Bin-Juine Huang,et al.  Development of hybrid solar-assisted cooling/heating system , 2010 .

[25]  Saffa Riffat,et al.  CFD modelling and experimental investigation of an ejector refrigeration system using methanol as the working fluid , 2001 .

[26]  Bin-Juine Huang,et al.  Performance of ejector cooling system with thermal pumping effect using R141b and R365mfc , 2009 .

[27]  Thanarath Sriveerakul,et al.  Development of a circulating system for a jet refrigeration cycle , 2008 .

[28]  Saffa Riffat,et al.  Study of a gas-liquid ejector and its application to a solar-powered bi-ejector refrigeration system , 2005 .

[29]  S. T. Taylor,et al.  HVAC systems and equipment , 1990 .

[30]  Saffa Riffat,et al.  Recent developments in ejector refrigeration technologies , 2013 .

[31]  Y. Dobriansky,et al.  Concepts of self-acting circulation loops for downward heat transfer (reverse thermosiphons) , 2011 .

[32]  Bin-Juine Huang,et al.  Development of an ejector cooling system with thermal pumping effect , 2006 .

[33]  S. G. Chuech,et al.  Design and implementation of ejector driven micropump , 2007 .

[34]  Siaw Kiang Chou,et al.  Achieving better energy-efficient air conditioning - A review of technologies and strategies , 2013 .

[35]  Saffa Riffat,et al.  Development of a solar-powered passive ejector cooling system , 2001 .

[36]  Jianyong Chen,et al.  A review on versatile ejector applications in refrigeration systems , 2015 .

[37]  Abdul Khaliq,et al.  Performance analysis of a waste‐heat‐powered thermodynamic cycle for multieffect refrigeration , 2015 .

[38]  Behrooz M. Ziapour,et al.  First and second laws analysis of the heat pipe/ejector refrigeration cycle , 2010 .

[39]  M Ouzzane,et al.  Model development and numerical procedure for detailed ejector analysis and design , 2003 .