Characterisation of reversed-phase liquid chromatographic columns by chromatographic tests. Rational column classification by a minimal number of column test parameters.

[1]  U. Neue,et al.  Universal procedure for the assessment of the reproducibility and the classification of silica-based reversed-phase packings: II. Classification of reversed-phase packings , 1999 .

[2]  S. Ounnar,et al.  Data analysis. a bridge between factor analysis and chromatography , 1999 .

[3]  H. Engelhardt,et al.  Characterization of reversed phases by chemometric methods , 1991 .

[4]  P. Carr,et al.  A Simple Test for Characterizing Silanophilic Interactions of Reversed-Phase Columns Based on the Chromatographic Behavior of Cyclic Tetraaza Compounds , 1983 .

[5]  K. Jinno,et al.  Chromatographic Characterization of Silica C18 Packing Materials. Correlation between a Preparation Method and Retention Behavior of Stationary Phase , 1989 .

[6]  T. Daldrup,et al.  A simple test to characterise C8/C18-bonded phases, particularly for toxicological screening , 1984 .

[7]  Anders Berglund,et al.  New and old trends in chemometrics. How to deal with the increasing data volumes in R&D&P (research, development and production)—with examples from pharmaceutical research and process modeling , 2002 .

[8]  W. Eymann HPLC in industry—A well established procedure for characterizing RP-stationary phases , 1997 .

[9]  J. Anderson,et al.  A comparison of silica-based C18 and C8 HPLC columns to aid column selection , 1995 .

[10]  C. Lochmüller,et al.  The Sorption Behavior of Alkyl Bonded Phases in Reverse-Phase, High Performance Liquid Chromatography , 1979 .

[11]  G. Guiochon,et al.  Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatography columns: I. Experimental protocol , 1999 .

[12]  A. Goldberg Comparison of columns for reversed-phase liquid chromatography , 1982 .

[13]  H. Engelhardt,et al.  Chromatographic determination of metallic impurities in reversed-phase HPLC columns. , 1999, Analytical chemistry.

[14]  Lynette A. Hunt,et al.  Fitting a Mixture Model to Three-mode Three-way Data with Missing Information , 2001, J. Classif..

[15]  B. Olsen,et al.  Chemometric categorization of octadecylsilyl bonded-phase silica columns using test mixtures and confirmation of results with pharmaceutical compound separations , 1995 .

[16]  D. McCalley,et al.  Evaluation of reversed-phase columns for the analysis of very basic compounds by high-performance liquid chromatography: Application to the determination of the tobacco alkaloids , 1993 .

[17]  C. Dewaele,et al.  The evaluation of “reversed phase” high-performance liquid chromatography packing materials , 1984 .

[18]  U. Neue,et al.  Universal procedure for the assessment of the reproducibility and the classification of silica-based reversed-phase packings: I. Assessment of the reproducibility of reversed-phase packings , 1999 .

[19]  S. V. Galushko The calculation of retention and selectivity in reversed-phase liquid chromatography II. Methanol-water eluents , 1993 .

[20]  A. Ferrer,et al.  Dealing with missing data in MSPC: several methods, different interpretations, some examples , 2002 .

[21]  D. Massart,et al.  Minimal number of chromatographic test parameters for the characterisation of reversed-phase liquid chromatographic stationary phases. , 2002, Journal of chromatography. A.

[22]  Á. Sándi,et al.  Characterization of different RP-HPLC columns by a gradient elution technique , 1997 .

[23]  C. Hackett,et al.  Chromatographic classification of commercially available reverse-phase HPLC columns , 1997 .

[24]  R. Brereton,et al.  High-performance liquid chromatography of basic compounds: Problems, possible solutions and tests of reversed-phase columns , 1998 .

[25]  Y. Heyden,et al.  Characterisation of reversed-phase liquid chromatographic columns by chromatographic tests. Evaluation of 36 test parameters: repeatability, reproducibility and correlation. , 2002, Journal of chromatography. A.

[26]  D. Massart,et al.  Spectral Mapping Analysis: A Method for the Characterization of Stationary Phases , 1994 .

[27]  R. Scott,et al.  Examination of five commercially available liquid chromatographic reversed phases (including the nature of the solute-solvent-stationary phase interactions associated with them) , 1977 .

[28]  L. A. Lopez,et al.  Comparison of methods for characterization of reversed-phase liquid chromatographic selectivity. , 2002, Journal of chromatography. A.

[29]  M. Jungheim,et al.  Comparison and characterization of reversed phases , 1990 .

[30]  A. N. Papas,et al.  Chemometric classification of reversed-phase high-performance liquid chromatography columns. , 1987, Journal of chromatography.