Low-complexity R-peak detection for ambulatory fetal monitoring

Non-invasive fetal health monitoring during pregnancy is becoming increasingly important because of the increasing number of high-risk pregnancies. Despite recent advances in signal-processing technology, which have enabled fetal monitoring during pregnancy using abdominal electrocardiogram (ECG) recordings, ubiquitous fetal health monitoring is still unfeasible due to the computational complexity of noise-robust solutions. In this paper, an ECG R-peak detection algorithm for ambulatory R-peak detection is proposed, as part of a fetal ECG detection algorithm. The proposed algorithm is optimized to reduce computational complexity, without reducing the R-peak detection performance compared to the existing R-peak detection schemes. Validation of the algorithm is performed on three manually annotated datasets. With a detection error rate of 0.23%, 1.32% and 9.42% on the MIT/BIH Arrhythmia and in-house maternal and fetal databases, respectively, the detection rate of the proposed algorithm is comparable to the best state-of-the-art algorithms, at a reduced computational complexity.

[1]  Arch D. Robison N-bit unsigned division via n-bit multiply-add , 2005, 17th IEEE Symposium on Computer Arithmetic (ARITH'05).

[2]  K. Maršál,et al.  Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial , 2001, The Lancet.

[3]  G S Dawes,et al.  Criteria for the design of fetal heart rate analysis systems. , 1990, International journal of bio-medical computing.

[4]  Massimo Mischi,et al.  Inter-electrode delay estimators for electrohysterographic propagation analysis , 2009, Physiological measurement.

[5]  Robert A. Robergs,et al.  The surprising history of the "HRmax=220-age" equation , 2002 .

[6]  P. Laguna,et al.  Evaluation of a wavelet-based ECG waveform detector on the QT database , 2000, Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163).

[7]  B. Schifrin,et al.  INTRAPARTUM ELECTRONIC FETAL HEART RATE MONITORING VERSUS INTERMITTENT AUSCULTATION: A META‐ANALYSIS , 1995, Obstetrics and gynecology.

[8]  Paul S. Addison,et al.  Continuous Wavelet Transform Modulus Maxima Analysis of the Electrocardiogram: Beat Characterisation and Beat-to-Beat Measurement , 2005, Int. J. Wavelets Multiresolution Inf. Process..

[9]  P. Strobach,et al.  Event-synchronous cancellation of the heart interference in biomedical signals , 1994, IEEE Transactions on Biomedical Engineering.

[10]  P. C. Cortez,et al.  A new approach to QRS segmentation based on wavelet bases and adaptive threshold technique. , 2007, Medical engineering & physics.

[11]  Hyung-Ro Yoon,et al.  Comparison of CWT with DWT for detecting Qrs Complex on Wearable ECG Recorder , 2010, 2010 International Conference on Wavelet Analysis and Pattern Recognition.

[12]  S. Abboud,et al.  Spectral analysis of the fetal electrocardiogram. , 1989, Computers in biology and medicine.

[13]  A. Vintzileos,et al.  Comparison of intrapartum electronic fetal heart rate monitoring versus intermittent auscultation in detecting fetal acidemia at birth. , 1995, American journal of obstetrics and gynecology.

[14]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[15]  N. Fisk,et al.  Non‐invasive fetal electrocardiography in singleton and multiple pregnancies , 2003, BJOG : an international journal of obstetrics and gynaecology.

[16]  Carsten Meyer,et al.  Combining Algorithms in Automatic Detection of QRS Complexes in ECG Signals , 2006, IEEE Transactions on Information Technology in Biomedicine.

[17]  E. Mulder,et al.  Fetal electrocardiography: feasibility of long‐term fetal heart rate recordings , 2009, BJOG : an international journal of obstetrics and gynaecology.

[18]  J. Palmgren,et al.  Sinistrality—a side-effect of prenatal sonography: A comparative study of young men , 2001, Epidemiology.

[19]  R. E. Tainsh,et al.  Fetal heart rate monitoring. , 1983, American journal of obstetrics and gynecology.

[20]  J. Huisken,et al.  Low-power robust beat detection in ambulatory cardiac monitoring , 2009, 2009 IEEE Biomedical Circuits and Systems Conference.

[21]  B. Widrow,et al.  Adaptive noise cancelling: Principles and applications , 1975 .

[22]  R. Orglmeister,et al.  The principles of software QRS detection , 2002, IEEE Engineering in Medicine and Biology Magazine.

[23]  N. Fisk,et al.  Non‐invasive intrapartum fetal ECG: preliminary report , 2005, BJOG : an international journal of obstetrics and gynaecology.

[24]  Asoke K. Nandi,et al.  Foetal PQRST extraction from ECG recordings using cyclostationarity-based source separation method , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[25]  C. Li,et al.  Detection of ECG characteristic points using wavelet transforms. , 1995, IEEE transactions on bio-medical engineering.

[26]  R Vullings,et al.  Dynamic segmentation and linear prediction for maternal ECG removal in antenatal abdominal recordings , 2009, Physiological measurement.

[27]  F. Gritzali Towards a generalized scheme for QRS detection in ECG waveforms , 1988 .

[28]  M. Peters,et al.  Monitoring the fetal heart non-invasively: a review of methods , 2001, Journal of perinatal medicine.

[29]  Piet Bergveld,et al.  A New Technique for the Suppression of the MECG , 1981, IEEE Transactions on Biomedical Engineering.

[30]  Ismet Sahin,et al.  A Method for Subsample Fetal Heart Rate Estimation Under Noisy Conditions , 2010, IEEE Transactions on Biomedical Engineering.

[31]  Paul S. Addison,et al.  The Illustrated Wavelet Transform Handbook , 2002 .

[32]  M. Morgan,et al.  Intrapartum electronic fetal heart rate monitoring versus intermittent auscultation: a meta-analysis. , 1995, Obstetrics and gynecology.

[33]  Rodica Strungaru,et al.  Fetal ECG extraction during labor using an adaptive maternal beat subtraction technique , 2007, Biomedizinische Technik. Biomedical engineering.

[34]  G Papakonstantinou,et al.  Detection of the P and T waves in an ECG. , 1989, Computers and biomedical research, an international journal.

[35]  Pablo Laguna,et al.  A wavelet-based ECG delineator: evaluation on standard databases , 2004, IEEE Transactions on Biomedical Engineering.