Radiation Effects on the Performance of CMOS Photodiode Array Detectors and the Role of Gain-Offset Corrections

We report the observation of performance degradation in a detector consisting of a phosphor screen and a CMOS (complementary metal-oxide-semiconductor) photodiode array under the continuous irradiation of 45-kVp x-rays. The performance was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). From the measurement results, it has been observed that the increase of dark pixel signal and the related noise gradually reduces the dynamic range as the cumulative input exposure to the detector increases. Severe degradation in NPS was observed, which gives rise to reduction in DQE as the cumulative input exposure increases. With carefully updated offset and gain correction, however, we can overcome the detrimental effects of increased dark current on NPS and DQE.

[1]  Kunio Doi,et al.  A simple method for determining the modulation transfer function in digital radiography , 1992, IEEE Trans. Medical Imaging.

[2]  Gyuseong Cho,et al.  Use of a flat-panel detector for microtomography: a feasibility study for small-animal imaging , 2005 .

[3]  H.J. Barnaby,et al.  Total-Ionizing-Dose Effects in Modern CMOS Technologies , 2006, IEEE Transactions on Nuclear Science.

[4]  Ho Kyung Kim,et al.  Computational Toolset for X-Ray Spectral Analysis , 2006 .

[5]  Thorsten Graeve,et al.  High-resolution CMOS imaging detector , 2001, SPIE Medical Imaging.

[6]  Ruola Ning,et al.  Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation , 2000, IEEE Transactions on Medical Imaging.

[7]  L. Antonuk,et al.  Radiation damage of amorphous silicon, thin-film, field-effect transistors. , 1996, Medical physics.

[8]  Min Hyoung Cho,et al.  A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. , 2003, Physics in medicine and biology.

[9]  Ehsan Samei,et al.  An experimental comparison of detector performance for direct and indirect digital radiography systems. , 2003, Medical physics.

[10]  Bart Dierickx,et al.  Total dose effects on CMOS active pixel sensors , 2000, Electronic Imaging.

[11]  Min Kook Cho,et al.  Characterization of CMOS Pixel Detectors for Digital X-Ray Imaging , 2006 .

[12]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[13]  Larry E. Antonuk,et al.  Radiation damage of amorphous silicon photodiode sensors , 1994 .