Synchronisation of a multi-motor speed control system

Purpose – The purpose of this research is to compare an industrial ethernet based network (PROFINET Class 1) with a traditional fieldbus network (PROFIBUS). Design/methodology/approach – Two sets of identical motors were used in the experimental set-up. The speed synchronisation of a lead and follower motors was compared using both PROFINET Class 1 and a PROFIBUS DP network. The level of synchronising achievable was used as a measure of performance for each network. Findings – It was found that PROFIBUS DP produces a better performance for set point and load changes than PROFINET Class 1 network. Research limitations/implications – PROFINET Class 2 and higher could not be used in the experiment due to availability of equipment and funding. Practical implications – This research provides a comparative study of two very popular industrial networks. The results can be used as reference by industry for selection of industrial networks. Originality/value – The paper provides a manufacturer independent practica...

[1]  J. G. Ziegler,et al.  Optimum Settings for Automatic Controllers , 1942, Journal of Fluids Engineering.

[2]  Yang Qingyu,et al.  Design of Motion Control System Used for Filter Rod Production Machine , 2006, 2006 CES/IEEE 5th International Power Electronics and Motion Control Conference.

[3]  Dawn M. Tilbury,et al.  PLC Communication using PROFINET: Experimental Results and Analysis , 2006, 2006 IEEE Conference on Emerging Technologies and Factory Automation.

[4]  Suk Lee,et al.  Remote fuzzy logic control of networked control system via Profibus-DP , 2003, IEEE Trans. Ind. Electron..

[5]  R. Alvarez,et al.  Comparison of multi-motor synchronization techniques , 2004, 30th Annual Conference of IEEE Industrial Electronics Society, 2004. IECON 2004.

[6]  Qiang Wang,et al.  Synchronization Control Strategy of Multi-motor System Based on Profibus Network , 2007, 2007 IEEE International Conference on Automation and Logistics.

[7]  Alessandra Flammini,et al.  Large PROFINET IO RT networks for factory automation: A case study , 2011, ETFA2011.

[8]  Cemal Yilmaz,et al.  Network induced delay of asynchronous motor connected to Profibus-DP networks using fuzzy logic control algorithm , 2010, Expert Syst. Appl..

[9]  Josef Weigmann,et al.  Decentralization with PROFIBUS-DP: Architecture and Fundamentals, Configuration and Use with SIMATIC S7 , 2000 .

[10]  H. Kleines,et al.  Performance Aspects of PROFINET IO , 2008, IEEE Transactions on Nuclear Science.