The arterial system pressure-volume loop.

Although the ventricular P-V loop has become a popular tool to characterize aspects of the performance of the heart, an arterial system P-V loop has not yet been described. In principle, the volume stored in the arterial system (V) could be calculated by integrating the difference between inflow and outflow. In practice, however, flow out of the innumerable arterioles cannot be measured directly. To overcome this obstacle, it has been shown that outflow can be approximated by input pressure divided by total peripheral resistance. Recently, the classical Windkessel model was generalized with the concept of apparent arterial compliance (C(app)), the transfer function relating pressure and volume expressed in the frequency domain. The arterial system P-V loop serves as a time-domain representation of C(app). This simple technique provides the first known characterization of an arterial system P-V loop.

[1]  N. Stergiopulos,et al.  Total arterial inertance as the fourth element of the windkessel model. , 1999, American journal of physiology. Heart and circulatory physiology.

[2]  S. Shroff,et al.  Physiological relevance of T-tube model parameters with emphasis on arterial compliances. , 1995, The American journal of physiology.

[3]  F Shen,et al.  Impedance of arterial system simulated by viscoelastic t tubes terminated in windkessels. , 1989, The American journal of physiology.

[4]  J. Li,et al.  A New Description of Arterial Function: The Compliance-Pressure Loop , 1998, Angiology.

[5]  A Noordergraaf,et al.  Analog studies of the human systemic arterial tree. , 1969, Journal of biomechanics.

[6]  N. Westerhof,et al.  Aortic Input Impedance in Normal Man: Relationship to Pressure Wave Forms , 1980, Circulation.

[7]  Abraham Noordergraaf,et al.  Apparent arterial compliance. , 1998, American journal of physiology. Heart and circulatory physiology.

[8]  R. Burattini,et al.  Computer identification of models for the arterial tree input impedance: Comparison between two new simple models and first experimental results , 1982, Medical and Biological Engineering and Computing.

[9]  O. Frank,et al.  Die grundform des arteriellen pulses , 1899 .

[10]  N. Westerhof,et al.  An artificial arterial system for pumping hearts. , 1971, Journal of applied physiology.

[11]  Douglas A. Hettrick,et al.  True Arterial System Compliance Estimated From Apparent Arterial Compliance , 2000, Annals of Biomedical Engineering.

[12]  A. Goldberg,et al.  Maintenance of normal length improves protein balance and energy status in isolated rat skeletal muscles. , 1986, The American journal of physiology.

[13]  A Noordergraaf,et al.  Constructive and destructive addition of forward and reflected arterial pulse waves. , 2001, American journal of physiology. Heart and circulatory physiology.

[14]  N. Stergiopulos,et al.  Simple and accurate way for estimating total and segmental arterial compliance: The pulse pressure method , 1994, Annals of Biomedical Engineering.

[15]  N Westerhof,et al.  Evaluation of methods for estimation of total arterial compliance. , 1995, The American journal of physiology.

[16]  M E Safar,et al.  An evaluation of large arteries compliance in man. , 1979, The American journal of physiology.

[17]  K P Brin,et al.  Estimation of total arterial compliance: an improved method and evaluation of current methods. , 1986, The American journal of physiology.