Design and emission uniformity studies of a 1.5-MW gyrotron electron gun

We present the design and initial operation of a 96-kV 40-A magnetron injection gun for a 1.5-MW 110-GHz gyrotron. A critical parameter for the successful application of this electron gun is the uniformity of electron emission. The current-voltage curve of emission, at a series of temperatures, is measured. Analysis indicates that the work function of the emitter is 1.6 eV with a (total) spread of 0.07 /spl plusmn/ 0.01 eV. Measurement of the azimuthal emission uniformity with a rotating probe indicates that the work function variation around the azimuth, the global spread, is 0.04 /spl plusmn/ 0.02 eV. The spread due to local (microscopic scale) work function variations is then calculated to be 0.06 /spl plusmn/ 0.02 eV. Temperature variation can be ruled out as the cause of the observed emission nonuniformity.

[1]  R. Vaughan,et al.  A synthesis of the Longo and Eng cathode emission models , 1986, IEEE Transactions on Electron Devices.

[2]  B. G. Danly,et al.  High-power operation of a 170 GHz megawatt gyrotron , 1997 .

[3]  Takuji Kimura Experimental study of 1 MW, 170 GHz gyrotron oscillator , 1997 .

[4]  T. S. Chu,et al.  Recent progress in producing megawatt gyrotrons for ECH applications , 2000, 25th International Conference on Infrared and Millimeter Waves (Cat. No.00EX442).

[5]  R. E. Thomas,et al.  Investigation of scandate cathodes: emission, fabrication, and activation processes , 1989 .

[6]  M. Glyavin,et al.  Experimental studies of gyrotron electron beam systems , 1999 .

[7]  T. Grimm,et al.  Experimental Study of a Megawatt 200–300 GHz Gyrotron Oscillator , 1992 .

[8]  Manfred Thumm,et al.  Recent results of the 1-MW, 140-GHz, TE/sub 22,6/-mode gyrotron , 1999 .

[9]  M. Thumm,et al.  ITER R&D: Auxiliary Systems: Electron Cyclotron Heating and Current Drive System , 2001 .

[10]  J. C. Tonnerre,et al.  Evaluation of the work function distribution of impregnated cathodes , 1983 .

[11]  Koji Takahashi,et al.  1 MW and long pulse operation of Gaussian beam output gyrotron with CVD diamond window for fusion devices , 2001 .

[12]  E. Adler,et al.  Dispenser cathode life prediction model , 1984, 1984 International Electron Devices Meeting.

[13]  G. Eng A new correction to Schottky barrier lowering in cathodes , 1985 .

[14]  S. Tsimring,et al.  Gyrotron Electron Beams: Velocity and Energy Spread and Beam Instabilities , 2001 .

[15]  Stefan Illy,et al.  European high-power CW gyrotron development for ECRH systems , 2001 .

[16]  M. Yu. Glyavin,et al.  Experimental investigation of a 110 GHz/1 MW gyrotron with the one-step depressed collector , 1997 .

[17]  Thomas M. Antonsen,et al.  Effect of the azimuthal inhomogeneity of electron emission on gyrotron operation , 2001 .

[18]  A. S. Gilmour Principles of Traveling Wave Tubes , 1994 .

[19]  William B. Herrmannsfeldt,et al.  ELECTRON TRAJECTORY PROGRAM , 1979 .

[20]  M. Pedrozzi,et al.  Experimental investigation of a 140-GHz coaxial gyrotron oscillator , 2001 .

[21]  L. G. Popov,et al.  Development of 170 GHz/1 MW Russian gyrotron for ITER , 2001 .