In-vivo quantitative measurement of tissue oxygen saturation of human webbing using a transmission type continuous-wave near-infrared spectroscopy

Near-infrared spectroscopy (NIRS) is a noninvasive method for monitoring tissue oxygen saturation (StO2). Many commercial NIRS devices are presently available. However, the precision of those devices is relatively poor because they are using the reflectance-model with which it is difficult to obtain the blood volume and other unchanged components of the tissue. Human webbing is a thin part of the hand and suitable to measure spectral transmittance. In this paper, we present a method for measuring StO2 of human webbing from a transmissive continuous-wave nearinfrared spectroscopy (CW-NIRS) data. The method is based on the modified Beer-Lambert law (MBL) and it consists of two steps. In the first step, we give a pressure to the upstream region of the measurement point to perturb the concentration of deoxy- and oxy-hemoglobin as remaining the other components and measure the spectral signals. From the measured data, spectral absorbance due to the components other than hemoglobin is calculated. In the second step, spectral measurement is performed at arbitrary time instance and the spectral absorbance obtained in the step 1 is subtracted from the measured absorbance. The tissue oxygen saturation (StO2) is estimated from the remained data. The method was evaluated on an arterial occlusion test (AOT) and a venous occlusion test (VOT). In the evaluation experiment, we confirmed that reasonable values of StO2 were obtained by the proposed method.

[1]  Takuo Aoyagi,et al.  Pulse oximetry: its invention, theory, and future , 2003, Journal of Anesthesia.

[2]  D. Delpy,et al.  Performance comparison of several published tissue near-infrared spectroscopy algorithms. , 1995, Analytical biochemistry.

[3]  D. Delpy,et al.  Use of the water absorption spectrum to quantify tissue chromophore concentration changes in near-infrared spectroscopy. , 1994, Physics in medicine and biology.

[4]  S. Arridge,et al.  Estimation of optical pathlength through tissue from direct time of flight measurement , 1988 .

[5]  Michaelis Ba,et al.  Pulse oximetry: Analysis of theory, technology, and practice , 2005, Journal of Clinical Monitoring.

[6]  Alessandro Torricelli,et al.  Determination of VIS- NIR absorption coefficients of mammalian fat, with time- and spatially resolved diffuse reflectance and transmission spectroscopy , 2004 .

[7]  Ching-Cheng Chuang,et al.  Hemodynamics Study Based on Near-Infrared Optical Assessment , 2012 .

[8]  Dean E. Myers,et al.  Noninvasive method for measuring local hemoglobin oxygen saturation in tissue using wide gap second derivative near-infrared spectroscopy. , 2005, Journal of biomedical optics.

[9]  S. Nicolson,et al.  Evaluation of pediatric near-infrared cerebral oximeter for cardiac disease. , 2012, The Annals of thoracic surgery.

[10]  A. M. Weindling,et al.  Measurement of venous oxyhaemoglobin saturation in the adult human forearm by near infrared spectroscopy with venous occlusion , 1997, Medical and Biological Engineering and Computing.

[11]  Brian E. Smith,et al.  4 Near-Infrared Spectroscopy , 2012 .

[12]  Ji-Hyun Lee,et al.  Comparison of two devices using near-infrared spectroscopy for the measurement of tissue oxygenation during a vascular occlusion test in healthy volunteers (INVOS® vs. InSpectra™) , 2015, Journal of Clinical Monitoring and Computing.

[13]  P. M. Lugarà,et al.  Application of near-infrared tissue oxymetry to the diagnosis of peripheral vascular disease. , 1999, Clinical hemorheology and microcirculation.

[14]  Masatsugu Niwayama,et al.  Craniofacial tissue oxygen saturation is associated with blood pH using an examiner's finger-mounted tissue oximetry in mice. , 2016, Journal of biomedical optics.

[15]  Denham S. Ward,et al.  Estimation of Jugular Venous O2 Saturation from Cerebral Oximetry or Arterial O2 Saturation during Isocapnic Hypoxia , 2004, Journal of Clinical Monitoring and Computing.