A monosegmented flow-batch system for slow reaction kinetics: spectrophotometric determination of boron in plants.

This work introduces the monosegmented flow-batch (MSFB) analysis concept. This system combines favourable characteristics of both flow-batch and the monosegmented analysers, allowing use of the flow-batch system for slow reaction kinetics without impairing sensitivity or sampling throughput. The MSFB was evaluated during spectrophotometric determination of boron in plant extracts, which is a method that involves a slow reaction between boron and azomethine-H. All calibration solutions were prepared in-line, and all analytical processes completed by simply changing the operational parameters in the MSFB control software. The limit of detection was estimated at 0.008 mg L(-1). The measurements could be performed at a rate of 120 samples per hour with satisfactory precision. The proposed MSFB was successfully applied to analyse 10 plant samples and the results are in agreement with the reference method at a 95% level of confidence.

[1]  B. F. Band,et al.  Flow-Batch Analyzer for the Chemiluminescence Determination of Catecholamines in Pharmaceutical Preparations , 2011 .

[2]  W. Fragoso,et al.  Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm. , 2008, Talanta.

[3]  M. C. U. Araújo,et al.  Automatic determination of chlorine without standard solutions using a biamperometric flow-batch analysis system. , 2010, Talanta.

[4]  C. Pasquini,et al.  Spectrophotometric Determination of Chromium ( VI ) , Ammonia , and Phosphorus , 2022 .

[5]  Sérgio R. B. Santos,et al.  Flow-batch miniaturization. , 2011, Talanta.

[6]  Spas D. Kolev,et al.  Advances in flow injection analysis and related techniques , 2008 .

[7]  S. C. B. Oliveira,et al.  A coulometric flow cell for in-line generation of reagent, titrant or standard solutions , 2006 .

[8]  F. Krug,et al.  Flow injection spectrophotometric determination of boron in plant material with azomethine-H , 1981 .

[9]  Gong Zhengjun,et al.  Flow injection kinetic spectrophotometric determination of trace amounts of Se(IV) in seawater. , 2005, Talanta.

[10]  Paula R. Fortes,et al.  Mixing chambers in flow analysis: A review , 2009 .

[11]  Ricardo S. Honorato,et al.  A flow-batch titrator exploiting a one-dimensional optimisation algorithm for end point search , 1999 .

[12]  Claudia E Domini,et al.  Automatized flow-batch method for fluorescent determination of free glycerol in biodiesel samples using on-line extraction. , 2012, Talanta.

[13]  A. Araújo,et al.  A flow-batch internal standard procedure for iron determination in hydrated ethanol fuel by flame atomic absorption spectrometry. , 2006, Talanta.

[14]  S. Ohira,et al.  Automated measurement of urinary creatinine by multichannel kinetic spectrophotometry. , 2009, Analytical biochemistry.

[15]  M. C. U. Araújo,et al.  Turbidimetric and photometric determination of total tannins in tea using a micro-flow-batch analyzer. , 2012, Talanta.

[16]  Jc Deandrade,et al.  SPECTROPHOTOMETRIC DETERMINATION OF BORON IN PLANTS USING MONOSEGMENTED CONTINUOUS-FLOW ANALYSIS , 1988 .

[17]  M. Pistonesi,et al.  A new automated approach to determine monosodium glutamate in dehydrated broths by using the flow-batch methodology. , 2010, Talanta: The International Journal of Pure and Applied Analytical Chemistry.

[18]  V. Gold Compendium of chemical terminology , 1987 .

[19]  C. Pasquini,et al.  Robust flow-batch coulometric/biamperometric titration system: determination of bromine index and bromine number of petrochemicals. , 2007, Analytica chimica acta.

[20]  Sérgio R. B. Santos,et al.  Hardness screening of water using a flow-batch photometric system , 2004 .

[21]  M. C. U. Araújo,et al.  Multicommutated generation of concentration gradients in a flow-batch system for metronidazole spectrophotometric determination in drugs , 2004 .

[22]  A. Nogueira,et al.  Multi-site detection in flow analysis , 1993 .

[23]  M. C. U. Araújo,et al.  Prior assay as an approach to flow titrations. Spectrophotometric determination of iron in alloys and ores , 2000 .

[24]  M. C. U. Araújo,et al.  Kinetics independent spectrometric analysis using non-linear calibration modelling and exploitation of concentration gradients generated by a flow-batch system for albumin and total protein determination in blood serum. , 2010, Talanta.

[25]  M. Arruda,et al.  A simple stopped-flow method with continuous pumping for the spectrophotometric flow-injection determination of boron in plants , 1987 .

[26]  F. Krug,et al.  Multicommutation in flow analysis exploiting a multizone trapping approach: spectrophotometric determination of boron in plants , 1998 .

[27]  I. Raimundo Automated Monosegmented Flow Analyser. Determination of Glucose, Creatinine and Urea , 1997 .