Improved Performance of M-Class PMUs Based on a Magnitude Compensation Model for Wide Frequency Deviations

Phasor measurement units (PMUs) are important elements in power systems to monitor and know the real network condition. In order to regulate the performance of PMUs, the IEEE Std. C37.118.1 stablishes two classes—P and M, where the phasor estimation is carried out using a quadrature oscillator and a low-pass (LP) filter for modulation and demodulation, respectively. The LP filter plays the most important role since it determines the accuracy, response time and rejection capability of both harmonics and aliased signals. In this regard and by considering that the M-class filters are used for more accurate measurements, the IEEE Std. presents different M-class filters for different reporting rates (when a result is given). However, they can degrade their performance under frequency deviations if the LP frequency response is not properly considered. In this work, a unified model for magnitude compensation under frequency deviations for all the M-class filters is proposed, providing the necessary values of compensation to improve their performance. The model considers the magnitude response of the M-class filters for different reporting rates, a normalized frequency range based on frequency dilation and a fitted two-variable function. The effectiveness of the proposal is verified using both static and dynamic conditions for frequency deviations. Besides that, a real-time simulator to generate test signals is also used to validate the proposed methodology.

[1]  Mohammad Hoseintabar Marzebali,et al.  An adaptive droop-based control strategy for fuel cell-battery hybrid energy storage system to support primary frequency in stand-alone microgrids , 2020 .

[2]  Francisco Javier Gomez-Gil,et al.  Feasibility of a Simple Small Wind Turbine with Variable-Speed Regulation Made of Commercial Components , 2013 .

[3]  Ashok Kumar Pradhan,et al.  Wide area measurement based protection support during power swing , 2014 .

[4]  Alexandre C. B. Delbem,et al.  Genetic algorithms applied to phasor estimation and frequency tracking in PMU development , 2013 .

[5]  Carmine Landi,et al.  A Tuned Lightweight Estimation Algorithm for Low-Cost Phasor Measurement Units , 2018, IEEE Transactions on Instrumentation and Measurement.

[6]  A.G. Phadke,et al.  Exploring the IEEE Standard C37.118–2005 Synchrophasors for Power Systems , 2008, IEEE Transactions on Power Delivery.

[7]  Issarachai Ngamroo,et al.  Intelligent photovoltaic farms for robust frequency stabilization in multi-area interconnected power system based on PSO-based optimal Sugeno fuzzy logic control , 2015 .

[8]  G. M. Burt,et al.  P and M Class Phasor Measurement Unit Algorithms Using Adaptive Cascaded Filters , 2013, IEEE Transactions on Power Delivery.

[9]  Geza Joos,et al.  Wide Frequency Range Adaptive Phasor and Frequency PMU Algorithms , 2014, IEEE Transactions on Smart Grid.

[10]  Pradipta Kishore Dash,et al.  A quadratic polynomial signal model and fuzzy adaptive filter for frequency and parameter estimation of nonstationary power signals , 2016 .

[11]  Ranjana Sodhi,et al.  A Novel Distribution-Level Phasor Estimation Algorithm Using Empirical Wavelet Transform , 2018, IEEE Transactions on Industrial Electronics.

[12]  Soon-Ryul Nam,et al.  Non-recursive Discrete Fourier Transform-Based Frequency Estimation of the Power System , 2019, Journal of Electrical Engineering & Technology.

[13]  Jing Zhang,et al.  Synchronous Generator Emulation Control Strategy for Voltage Source Converter (VSC) Stations , 2015, IEEE Transactions on Power Systems.

[14]  Tianshu Bi,et al.  An improved Taylor weighted least squares method for estimating synchrophasor , 2020 .

[15]  Mladen Kezunovic,et al.  Characterizing dynamic behavior of PMUs using step signals , 2011 .

[16]  Yi Liu,et al.  A Method for Sizing Energy Storage System to Increase Wind Penetration as Limited by Grid Frequency Deviations , 2016, IEEE Transactions on Power Systems.

[17]  Martin Valtierra-Rodriguez,et al.  A Phasor Estimation Algorithm based on Hilbert Transform for P-class PMUs , 2018 .

[18]  Martin Valtierra-Rodriguez,et al.  A New Phasor Estimator for PMU Applications: P Class and M Class , 2020, Journal of Modern Power Systems and Clean Energy.

[19]  Pavlos S. Georgilakis,et al.  Technical challenges associated with the integration of wind power into power systems , 2008 .

[20]  Anurag K. Srivastava,et al.  A review of synchrophasor applications in smart electric grid , 2017 .

[21]  Roque Alfredo Osornio-Rios,et al.  A Hilbert Transform-Based Smart Sensor for Detection, Classification, and Quantification of Power Quality Disturbances , 2013, Sensors.

[22]  Abdul Motin Howlader,et al.  Active power control to mitigate voltage and frequency deviations for the smart grid using smart PV inverters , 2020 .

[23]  Soon-Ryul Nam,et al.  Real-Time Estimation of Power System Frequency Using a Three-Level Discrete Fourier Transform Method , 2014 .

[24]  Geza Joos,et al.  Compliance Analysis of PMU Algorithms and Devices for Wide-Area Stabilizing Control of Large Power Systems , 2013, IEEE Transactions on Power Systems.

[25]  A.G. Phadke,et al.  Synchronized Phasor and Frequency Measurement Under Transient Conditions , 2009, IEEE Transactions on Power Delivery.

[26]  I Kamwa,et al.  Adaptive Phasor and Frequency-Tracking Schemes for Wide-Area Protection and Control , 2011, IEEE Transactions on Power Delivery.

[27]  Tianshu Bi,et al.  Dynamic Phasor Model-Based Synchrophasor Estimation Algorithm for M-Class PMU , 2015, IEEE Transactions on Power Delivery.

[28]  Darko Marcetic,et al.  Active power measurement algorithm for power system signals under non-sinusoidal conditions and wide-range frequency deviations , 2009 .

[29]  Paolo Castello,et al.  Impact of the Model on the Accuracy of Synchrophasor Measurement , 2012, IEEE Transactions on Instrumentation and Measurement.

[30]  Weidong Li,et al.  A New Control Logic for a Wind-Area on the Balancing Authority Area Control Error Limit Standard for Load Frequency Control , 2018 .

[31]  Dawei Fan,et al.  Phasor-Based Synchronized Frequency Measurement in Power Systems , 2007, IEEE Transactions on Power Delivery.

[32]  David Granados-Lieberman Global Harmonic Parameters for Estimation of Power Quality Indices: An Approach for PMUs , 2020 .

[33]  Diambomba H. Tungadio,et al.  Optimal frequency deviations control in microgrid interconnected systems , 2019, IET Renewable Power Generation.

[34]  M. S. Sachdev,et al.  Off-Nominal Frequency Measurements in Electric Power Systems , 1989, IEEE Power Engineering Review.

[36]  Athula D. Rajapakse,et al.  Testing and Enhancement of the Dynamic Performance of a Phasor Measurement Unit , 2014 .

[37]  I. Kamwa,et al.  Extended C37.118.1 PMU Algorithms for Joint Tracking of Fundamental and Harmonic Phasors in Stressed Power Systems and Microgrids , 2014, IEEE Transactions on Power Delivery.

[38]  Constantin Bulac,et al.  Optimal Phase Load Balancing in Low Voltage Distribution Networks Using a Smart Meter Data-Based Algorithm , 2020 .

[39]  X. Liu,et al.  Principal Component Analysis of Wide-Area Phasor Measurements for Islanding Detection—A Geometric View , 2015, IEEE Transactions on Power Delivery.

[40]  Andrew J. Roscoe,et al.  Exploring the Relative Performance of Frequency-Tracking and Fixed-Filter Phasor Measurement Unit Algorithms Under C37.118 Test Procedures, the Effects of Interharmonics, and Initial Attempts at Merging P-Class Response With M-Class Filtering , 2013, IEEE Transactions on Instrumentation and Measurement.

[41]  Subhransu Ranjan Samantaray,et al.  Phasor measurement unit based wide-area monitoring and information sharing between micro-grids , 2017 .

[42]  Hatem H. Zeineldin,et al.  Gain compensation approach for low‐voltage ride‐through and dynamic performance improvement of three‐phase type‐3 PLL , 2020, IET Power Electronics.

[43]  Alessandro Ferrero,et al.  Measuring electric power quality: Problems and perspectives , 2008 .

[44]  Wenjuan Du,et al.  Optimal Sizing and Control Strategies for Hybrid Storage System as Limited by Grid Frequency Deviations , 2018, IEEE Transactions on Power Systems.

[45]  Tevfik Sezi,et al.  Considerations about synchrophasors measurement in dynamic system conditions , 2009 .