Avoiding the pitfalls of single particle cryo-electron microscopy: Einstein from noise

Single particle cryo-electron microscopy is currently poised to produce high-resolution structures of many biological assemblies, but several pitfalls can trap the unwary. This critique highlights one problem that is particularly relevant when smaller structures are being studied. It is known as “Einstein from noise,” in which the experimenter honestly believes they have recorded images of their particles, whereas in reality, most if not all of their data consist of pure noise. Selection of particles using cross-correlation methods can then lead to 3D maps that resemble the model used in the initial selection and provide the illusion of progress. Suggestions are given about how to circumvent the problem.

[1]  Wen Jiang,et al.  EMAN2: an extensible image processing suite for electron microscopy. , 2007, Journal of structural biology.

[2]  Fred J Sigworth,et al.  Three‐dimensional structure of the type 1 inositol 1,4,5‐trisphosphate receptor at 24 Å resolution , 2002, The EMBO journal.

[3]  Toshihiko Ogura,et al.  Inositol 1,4,5-trisphosphate receptor contains multiple cavities and L-shaped ligand-binding domains. , 2004, Journal of molecular biology.

[4]  R. Henderson Realizing the potential of electron cryo-microscopy , 2004, Quarterly Reviews of Biophysics.

[5]  N Grigorieff,et al.  Resolution measurement in structures derived from single particles. , 2000, Acta crystallographica. Section D, Biological crystallography.

[6]  R. Henderson,et al.  Optimal determination of particle orientation, absolute hand, and contrast loss in single-particle electron cryomicroscopy. , 2003, Journal of molecular biology.

[7]  Youdong Mao,et al.  Molecular architecture of the uncleaved HIV-1 envelope glycoprotein trimer , 2013, Proceedings of the National Academy of Sciences.

[8]  R. Henderson,et al.  High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy☆ , 2013, Ultramicroscopy.

[9]  Youdong Mao,et al.  Molecular architecture of the uncleaved HIV-1 envelope glycoprotein trimer , 2013, Retrovirology.

[10]  Xing Zhang,et al.  3.3 Å Cryo-EM Structure of a Nonenveloped Virus Reveals a Priming Mechanism for Cell Entry , 2010, Cell.

[11]  Marin van Heel,et al.  Finding trimeric HIV-1 envelope glycoproteins in random noise , 2013 .

[12]  S. Scheres,et al.  Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles , 2013, eLife.

[13]  M. Shatsky,et al.  A method for the alignment of heterogeneous macromolecules from electron microscopy. , 2009, Journal of structural biology.

[14]  Youdong Mao,et al.  Reply to Subramaniam, van Heel, and Henderson: Validity of the cryo-electron microscopy structures of the HIV-1 envelope glycoprotein complex , 2013, Proceedings of the National Academy of Sciences.

[15]  R. Henderson The potential and limitations of neutrons, electrons and X-rays for atomic resolution microscopy of unstained biological molecules , 1995, Quarterly Reviews of Biophysics.

[16]  Sriram Subramaniam,et al.  Trimeric HIV-1 glycoprotein gp140 immunogens and native HIV-1 envelope glycoproteins display the same closed and open quaternary molecular architectures , 2011, Proceedings of the National Academy of Sciences.

[17]  Shaoxia Chen,et al.  Prevention of overfitting in cryo-EM structure determination , 2012, Nature Methods.

[18]  Joachim Frank,et al.  Particle-verification for single-particle, reference-based reconstruction using multivariate data analysis and classification. , 2008, Journal of structural biology.

[19]  Sriram Subramaniam,et al.  Structure of trimeric HIV-1 envelope glycoproteins , 2013, Proceedings of the National Academy of Sciences.

[20]  D. Agard,et al.  Electron counting and beam-induced motion correction enable near atomic resolution single particle cryoEM , 2013, Nature Methods.

[21]  Joseph Sodroski,et al.  Subunit organization of the membrane-bound HIV-1 envelope glycoprotein trimer , 2012, Nature Structural &Molecular Biology.

[22]  Judith M Short,et al.  SLEUTH--a fast computer program for automatically detecting particles in electron microscope images. , 2004, Journal of structural biology.

[23]  Michael Schatz,et al.  Four-Dimensional Cryo Electron Microscopy at Quasi Atomic Resolution: "IMAGIC 4D" , 2012 .

[24]  Katsuhiko Mikoshiba,et al.  Three-dimensional Rearrangements within Inositol 1,4,5-Trisphosphate Receptor by Calcium* , 2003, Journal of Biological Chemistry.

[25]  M. Baker,et al.  Outcome of the First Electron Microscopy Validation Task Force Meeting , 2012, Structure.

[26]  Richard Henderson,et al.  Tilt-Pair Analysis of Images from a Range of Different Specimens in Single-Particle Electron Cryomicroscopy , 2011, Journal of molecular biology.

[27]  John L Rubinstein,et al.  The resolution dependence of optimal exposures in liquid nitrogen temperature electron cryomicroscopy of catalase crystals. , 2010, Journal of structural biology.

[28]  W. Chiu,et al.  Validation of cryo-EM structure of IP₃R1 channel. , 2013, Structure.

[29]  Seigo Shima,et al.  De novo modeling of the F420-reducing [NiFe]-hydrogenase from a methanogenic archaeon by cryo-electron microscopy , 2013, eLife.

[30]  A M Roseman,et al.  FindEM--a fast, efficient program for automatic selection of particles from electron micrographs. , 2004, Journal of structural biology.

[31]  J. Dubochet,et al.  Cryo-electron microscopy of viruses , 1984, Nature.

[32]  S. Morris,et al.  Domain organization of the type 1 inositol 1,4,5-trisphosphate receptor as revealed by single-particle analysis , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[33]  Wah Chiu,et al.  Structure of Ca2+ release channel at 14 A resolution. , 2005, Journal of molecular biology.