Optimal Coordinated Design of Multiple Damping Controllers Based on PSS and UPFC Device to Improve Dynamic Stability in the Power System

Unified Power Flow Controller (UPFC) device is applied to control power flow in transmission lines. Supplementary damping controller can be installed on any control channel of the UPFC inputs to implement the task of Power Oscillation Damping (POD) controller. In this paper, we have presented the simultaneous coordinated design of the multiple damping controllers between Power System Stabilizer (PSS) and UPFC-based POD or between different multiple UPFC-based POD controllers without PSS in a single-machine infinite-bus power system in order to identify the design that provided the most effective damping performance. The parameters of the damping controllers are optimized utilizing a Chaotic Particle Swarm Optimization (CPSO) algorithm based on eigenvalue objective function. The simulation results show that the coordinated design of the multiple damping controllers has high ability in damping oscillations compared to the individual damping controllers. Furthermore, the coordinated design of UPFC-based POD controllers demonstrates the superiority over the coordinated design of PSS and UPFC-based POD controllers for enhancing greatly the stability of the power system.

[1]  Mostafa Sedighizadeh,et al.  Coordination of PSS and TCSC controller using modified particle swarm optimization algorithm to improve power system dynamic performance , 2009, Journal of Zhejiang University SCIENCE C.

[2]  H. F. Wang,et al.  Damping function of unified power flow controller , 1999 .

[3]  H.F. Wang,et al.  FACTS-based stabilizers to damp power system oscillations - a survey , 2004, 39th International Universities Power Engineering Conference, 2004. UPEC 2004..

[4]  Feng Gao,et al.  Developing a second nearest-neighbor modified embedded atom method interatomic potential for lithium , 2011 .

[5]  I. Kamwa,et al.  Robust design and coordination of multiple damping controllers using nonlinear constrained optimization , 1999, Proceedings of the 21st International Conference on Power Industry Computer Applications. Connecting Utilities. PICA 99. To the Millennium and Beyond (Cat. No.99CH36351).

[6]  Hussain Shareef,et al.  Coordinated design of PSS and SVC damping controller using CPSO , 2011, 2011 5th International Power Engineering and Optimization Conference.

[7]  Rafael S. Parpinelli,et al.  New inspirations in swarm intelligence: a survey , 2011, Int. J. Bio Inspired Comput..

[8]  M. A. Abido,et al.  A particle-swarm-based approach of power system stability enhancement with unified power flow controller , 2007 .

[9]  I. Erlich,et al.  Simultaneous coordinated tuning of PSS and FACTS damping controllers in large power systems , 2005, IEEE Transactions on Power Systems.

[10]  Seyed Abbas Taher,et al.  UPFC Location and Performance Analysis in Deregulated Power Systems , 2009 .

[11]  M. A. Abido,et al.  Robust coordinated design of excitation and TCSC-based stabilizers using genetic algorithms , 2004 .

[12]  Zhihua Cui,et al.  A second nearest-neighbor embedded atom method interatomic potential for Li-Si alloys , 2012 .

[13]  Percival Bueno de Araujo,et al.  Pole placement by coordinated tuning of Power System Stabilizers and FACTS-POD stabilizers , 2011 .

[14]  Rudy Gianto,et al.  Neural networks for adaptive control coordination of PSSs and FACTS devices in multimachine power system , 2008 .

[15]  Laszlo Gyugyi,et al.  Unified power-flow control concept for flexible AC transmission systems , 1992 .

[16]  Ebrahim Babaei,et al.  A QPSO based parameters tuning of the conventional power system stabilizer , 2010, 2010 Conference Proceedings IPEC.

[17]  Shaopeng Wang,et al.  Power system damping controller design-using multiple input signals , 2000 .

[18]  Om P. Malik,et al.  Small signal stability , 2015 .

[19]  Rajiv K. Varma,et al.  Thyristor-Based Facts Controllers for Electrical Transmission Systems , 2002 .

[20]  Amin Safari,et al.  Design of output feedback UPFC controller for damping of electromechanical oscillations using PSO , 2009 .

[21]  Ali T Al-Awami,et al.  Power system stability enhancement using unified power flow controllers , 2006, 2006 IEEE GCC Conference (GCC).

[22]  N. K. Roy,et al.  Damping of power system oscillations using STATCOM , 2015, 2015 2nd International Conference on Electrical Information and Communication Technologies (EICT).

[23]  Pouyan Pourbeik,et al.  Interactions between, and effectiveness of power system stabilizers and FACTS device stabilizers in multimachine systems , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[24]  Amin Safari,et al.  PSS and TCSC damping controller coordinated design using PSO in multi-machine power system , 2010 .

[25]  Reza Hemmati,et al.  Supplementary Stabilizer Design Based on STATCOM , 2011 .

[26]  E. Babaei,et al.  An improved PSO and genetic algorithm based damping controller used in UPFC for power system oscillations damping , 2011, 2011 International Conference on Electrical Machines and Systems.

[27]  James A. Momoh,et al.  Electric Power System Dynamics and Stability , 1999 .

[28]  Prechanon Kumkratug Power System Stability Enhancement Using Unified Power Flow Controller , 2010 .

[29]  B. Pal,et al.  Robust Control in Power Systems , 2005 .

[30]  E. Lerch,et al.  Optimization and Coordination of Damping Controls for Improving System Dynamic Performance , 2001, IEEE Power Engineering Review.