ELASTOGRAPHY USING FREEHAND ULTRASOUND

We present an elastography system using freehand 3D ultrasound. A review is provided of the standard elastography methods that have been adapted for this purpose. The scanning protocol is simple and promising results are presented of 3D strain images from freehand scans. Robustness is a problem, however, and the main sources of error are explained. Measures have been developed to improve the quality of the freehand images by means of dropout correction and frame filtering. Results from the application of these techniques provide an indication of development strands which should lead to a system that is both easy-to-use and produces reliable, high quality images.

[1]  A F van der Steen,et al.  Intravascular ultrasound elastography. , 2008, Ultraschall in der Medizin.

[2]  P. Chaturvedi,et al.  Testing the limitations of 2-D companding for strain imaging using phantoms , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Andrew H. Gee,et al.  3D elastography using freehand ultrasound. , 2006 .

[4]  M. Doyley,et al.  A freehand elastographic imaging approach for clinical breast imaging: system development and performance evaluation. , 2001, Ultrasound in medicine & biology.

[5]  F. Kallel,et al.  A Least-Squares Strain Estimator for Elastography , 1997, Ultrasonic imaging.

[6]  J. Ophir,et al.  Methods for Estimation of Subsample Time Delays of Digitized Echo Signals , 1995 .

[7]  Andrew H. Gee,et al.  3D Elastography Using Freehand Ultrasound , 2004, MICCAI.

[8]  Graham M. Treece,et al.  Engineering a freehand 3D ultrasound system , 2003, Pattern Recognit. Lett..

[9]  C. S. Spalding,et al.  In vivo real-time freehand palpation imaging. , 2003, Ultrasound in medicine & biology.

[10]  J. Ophir,et al.  An adaptive strain estimator for elastography , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  S.W. Smith,et al.  Speckle Pattern Correlation with Lateral Aperture Translation: Experimental Results and Implications for Spatial Compounding , 1986, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  H. Ermert,et al.  Real Time Strain Imaging — a new Ultrasonic Method for Cancer Detection: First Study Results , 2001 .

[13]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[14]  T. Varghese,et al.  A theoretical framework for performance characterization of elastography: the strain filter , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  H. Ermert,et al.  A time-efficient and accurate strain estimation concept for ultrasonic elastography using iterative phase zero estimation , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Graham M. Treece,et al.  High-definition freehand 3-D ultrasound. , 2003, Ultrasound in Medicine and Biology.

[17]  C. R. Hill,et al.  Measurement of soft tissue motion using correlation between A-scans. , 1982, Ultrasound in medicine & biology.

[18]  J. Ophir,et al.  Elastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast in Vivo , 1993, Ultrasonic imaging.

[19]  B. Garra,et al.  Elastography of breast lesions: initial clinical results. , 1997, Radiology.

[20]  G. Trahey,et al.  On the feasibility of remote palpation using acoustic radiation force. , 2001, The Journal of the Acoustical Society of America.

[21]  K. Parker,et al.  "Sonoelasticity" images derived from ultrasound signals in mechanically vibrated tissues. , 1990, Ultrasound in medicine & biology.

[22]  K J Parker,et al.  Tissue response to mechanical vibrations for "sonoelasticity imaging". , 1990, Ultrasound in medicine & biology.

[23]  Jonathan Ophir,et al.  Axial resolution in elastography. , 2002, Ultrasound in medicine & biology.

[24]  J. Ophir,et al.  The effect of nonlinear signal transformations on bias errors in elastography , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  J. Ophir,et al.  Reduction of Image Noise in Elastography , 1993 .

[26]  Richard James Housden,et al.  Sensorless freehand 3D ultrasound in real tissue: Speckle decorrelation without fully developed speckle , 2006, Medical Image Anal..

[27]  Nigel L. Bush,et al.  Freehand Elasticity Imaging Using Speckle Decorrelation Rate , 1996 .

[28]  S. Emelianov,et al.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics. , 1998, Ultrasound in medicine & biology.