Sapphire ball lensed fiber probe for common-path optical coherence tomography in ocular imaging and sensing

We describe a novel common-path optical coherence tomography (CP-OCT) fiber probe design using a sapphire ball lens for cross-sectional imaging and sensing in retina vitrectomy surgery. Single mode Gaussian beam (TEM00) simulation was used to optimize lateral resolution and working distance (WD) of the common-path probe. A theoretical sensitivity model for CP-OCT was prosed to assess its optimal performance based an unbalanced photodetector configuration. Two probe designs with working distances (WD) 415μm and 1221μm and lateral resolution 11μm and 18μm, respectively were implemented with sensitivity up to 88dB. The designs are also fully compatible with conventional Michelson interferometer based OCT configurations. The reference plane of the probe, located at the distal beam exit interface of the single mode fiber (SMF), was encased within a 25-gauge hypodermic needle by the sapphire ball lens facilitates its applications in bloody and harsh environments. The performances of the fiber probe with 11μm of lateral resolution and 19μm of axial resolution were demonstrated by cross-sectional imaging of a cow cornea and retina in vitro with a 1310nm swept source OCT system. This probe was also attached to a piezoelectric motor for active compensation of physiological tremor for handheld retinal surgical tools.

[1]  Shoude Chang,et al.  Graded-index fiber lens proposed for ultrasmall probes used in biomedical imaging. , 2007, Applied optics.

[2]  Adrian Mariampillai,et al.  Interstitial Doppler optical coherence tomography as a local tumor necrosis predictor in photodynamic therapy of prostatic carcinoma: an in vivo study. , 2008, Cancer research.

[3]  Jin U. Kang,et al.  Sapphire ball lens-based fiber probe for common-path optical coherence tomography and its applications in corneal and retinal imaging. , 2012, Optics letters.

[4]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[5]  Adam Wax,et al.  Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology. , 2011, Journal of biomedical optics.

[6]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[7]  J. Fujimoto,et al.  In vivo endoscopic optical biopsy with optical coherence tomography. , 1997, Science.

[8]  J G Fujimoto,et al.  Intraluminal fiber-optic Doppler imaging catheter for structural and functional optical coherence tomography. , 2001, Optics letters.

[9]  Chul Gyu Song,et al.  Endoscopic Functional Fourier Domain Common-Path Optical Coherence Tomography for Microsurgery , 2010, IEEE Journal of Selected Topics in Quantum Electronics.

[10]  S. Yun,et al.  High-speed optical frequency-domain imaging. , 2003, Optics express.

[11]  Y. Yasuno,et al.  Visualization of phase retardation of deep posterior eye by polarization-sensitive swept-source optical coherence tomography with 1-microm probe. , 2009, Optics express.

[12]  Jin U. Kang,et al.  Signal-to-noise ratio analysis of all-fiber common-path optical coherence tomography. , 2008, Applied optics.

[13]  R A McLaughlin,et al.  Ultrathin side-viewing needle probe for optical coherence tomography. , 2011, Optics letters.

[14]  Woonggyu Jung,et al.  Aberration characterization for the optimal design of high-resolution endoscopic optical coherence tomography catheters. , 2012, Optics letters.

[15]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[16]  Steven M. Jones,et al.  Adaptive-optics optical coherence tomography for high-resolution and high-speed 3D retinal in vivo imaging. , 2005, Optics express.

[17]  Joseph A Izatt,et al.  Single-camera sequential-scan-based polarization-sensitive SDOCT for retinal imaging. , 2009, Optics letters.

[18]  J. Izatt,et al.  3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea. , 2010, Optics express.