ANN-based soft starting of Voltage-controlled-fed IM drive system

Soft starters are used as induction motor controllers in compressors, blowers, fans, pumps, mixers, crushers and grinders, and many other applications. Soft starters use ac voltage controllers to start the induction motor and to adjust its speed. This paper presents a novel artifical neural network (ANN)-based ac voltage controller which generates the appropriate thyristors' firing angle for any given operating torque and speed of the motor and the load. An ANN model was designed for that purpose. The results obtained are very satisfactory and promising. The advantage of such a controller are its simplicity, stability, and high accuracy compared to conventional mathematical calculation of the firing angle which is a very complex and time consuming task especially in online control applications.

[1]  Frank M. Bruce,et al.  Reduced-Voltage Starting of Squirrel-Cage Induction Motors , 1984, IEEE Transactions on Industry Applications.

[2]  Howard B. Demuth,et al.  Neutral network toolbox for use with Matlab , 1995 .

[3]  Thomas A. Lipo The Analysis of Induction Motors with Voltage Control by Symmetrically Triggered Thyristors , 1971 .

[4]  J. Nevelsteen,et al.  Starting of large motors-methods and economics , 1988, Record of Conference Papers., Industrial Applications Society 35th Annual Petroleum and Chemical Industry Conference,.

[5]  M. Shan Griffith,et al.  Evaluating the Effects of Motor Starting on Industrial and Commercial Power Systems , 1978, IEEE Transactions on Industry Applications.

[6]  V. V. Sastry,et al.  Optimal soft starting of voltage-controller-fed IM drive based on voltage across thyristor , 1997 .

[7]  N. Mohan Improvement in Energy Efficiency of Induction Motors by Means of Voltage Control , 1980, IEEE Transactions on Power Apparatus and Systems.

[8]  Muammer Ermis,et al.  Soft starting of large induction motors at constant current with minimised starting torque pulsations , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[9]  Frede Blaabjerg,et al.  Can soft-starters help save energy? , 1997 .

[10]  Shashi B. Dewan,et al.  Power Semiconductor Drives , 1984 .

[11]  A. A. Shaltout,et al.  Analysis of torsional torques in starting of large squirrel cage induction motors , 1994 .

[12]  R. F. McElveen,et al.  Starting high-inertia loads , 2001 .