Hydrogen Leak Detection Using Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy (LIBS) is investigated as a technique for real-time monitoring of hydrogen gas. Two methodologies were examined: The use of a 100 mJ laser pulse to create a laser-induced breakdown directly in a sample gas stream, and the use of a 55 mJ laser pulse to create a laser-induced plasma on a solid substrate surface, with the expanding plasma sampling the gas stream. Various metals were analyzed as candidate substrate surfaces, including aluminum, copper, molybdenum, stainless steel, titanium, and tungsten. Stainless steel was selected, and a detailed analysis of hydrogen detection in binary mixtures of nitrogen and hydrogen at atmospheric pressure was performed. Both the gaseous plasma and the plasma initiated on the stainless steel surface generated comparable hydrogen emission signals, using the 656.28 Hα emission line, and exhibited excellent signal linearity. The limit of detection is about 20 ppm (mass) as determined for both methodologies, with the solid-initiated plasma yielding a slightly better value. Overall, LIBS is concluded to be a viable candidate for hydrogen sensing, offering a combination of high sensitivity with a technique that is well suited to implementation in field environments.

[1]  N. Arai,et al.  Spatially resolved elemental analysis of a hydrogen–air diffusion flame by laser-induced plasma spectroscopy (LIPS) , 2001 .

[2]  R. Nordstrom Study of Laser-Induced Plasma Emission Spectra of N2, O2, and Ambient Air in the Region 350 nm to 950 nm , 1995 .

[3]  S. Buckley,et al.  Laser-Induced Breakdown Spectroscopy for On-Line Engine Equivalence Ratio Measurements , 2003, Applied spectroscopy.

[4]  C. Parigger,et al.  Spatially and temporally resolved electron number density measurements in a decaying laser-induced plasma using hydrogen-alpha line profiles. , 1995, Applied optics.

[5]  P. Adam,et al.  Time-Resolved Laser-Induced Breakdown Spectroscopy: Application for Qualitative and Quantitative Detection of Fluorine, Chlorine, Sulfur, and Carbon in Air , 1998 .

[6]  J. B. Simeonsson,et al.  Time-resolved emission studies of ArF-laser-produced microplasmas. , 1993, Applied optics.

[7]  James D. Winefordner,et al.  Detection of Gaseous and Particulate Fluorides by Laser-Induced Breakdown Spectroscopy , 2001 .

[8]  A. Miziolek,et al.  Laser Induced Breakdown Spectroscopy (LIBS) for Real-Time Detection of Halon Alternative Agents , 1998, Laser Applications to Chemical, Security and Environmental Analysis.

[9]  J. A. Aguilera,et al.  Curves of growth of spectral lines emitted by a laser-induced plasma: influence of the temporal evolution and spatial inhomogeneity of the plasma , 2003 .

[10]  David W. Hahn,et al.  Sampling statistics and considerations for single-shot analysis using laser-induced breakdown spectroscopy , 2002 .

[11]  Marco A. Gigosos,et al.  New plasma diagnosis tables of hydrogen Stark broadening including ion dynamics , 1996 .

[12]  E. Oks A new spectroscopic effect resulting in a narrowing of hydrogen lines in dense plasmas , 2000 .

[13]  D. Hahn,et al.  Temporal analysis of laser-induced plasma properties as related to laser-induced breakdown spectroscopy , 2004 .

[14]  J. B. Simeonsson,et al.  Spectroscopic studies of laser-produced plasmas formed in CO and CO2 using 193, 266, 355, 532 and 1064 nm laser radiation , 1994 .

[15]  William L. Barr,et al.  Spectral Line Broadening by Plasmas , 1975, IEEE Transactions on Plasma Science.