Measurement of a cross-sectional area of normal and stenotic arteries with videodensitometric quantitative arteriography and intravascular ultrasound.
暂无分享,去创建一个
S. Molloi | W. Zhang | C. Leung | T. Hiro | J. Hicks | Takafumi Hiro | Cyril Y. Leung | Weifeng Zhang
[1] K. Gould,et al. AUTOMATED EVALUATION OF VESSEL DIAMETER FROM ARTERIOGRAMS. , 1983 .
[2] Johan H. C. Reiber,et al. Quantitative Coronary Arteriography , 1991 .
[3] J Hicks,et al. Quantification of volumetric coronary blood flow with dual-energy digital subtraction angiography. , 1996, Circulation.
[4] S. Molloi,et al. Absolute cross-sectional area measurements in quantitative coronary arteriography by dual-energy DSA. , 1991, Investigative radiology.
[5] M. LeFree,et al. Automated quantitative coronary arteriography: morphologic and physiologic validation in vivo of a rapid digital angiographic method. , 1987, Circulation.
[6] O Nalcioglu,et al. Videodensitometric determination of minimum coronary artery luminal diameter before and after angioplasty. , 1987, The American journal of cardiology.
[7] T Ema,et al. A technique of scatter-glare correction using a digital filtration. , 1993, Medical physics.
[8] R. Kruger. Estimation of the diameter of and iodine concentration within blood vessels using digital radiography devices. , 1981, Medical physics.
[9] Friedberg Ck. Computers in cardiology. , 1970 .
[10] J E Edwards,et al. Correlation of the Antemortem Coronary Arteriogram and the Postmortem Specimen , 1973, Circulation.
[11] P D Esser,et al. Quantification of relative coronary arterial stenosis by cinevideodensitometric analysis of coronary arteriograms. , 1984, Circulation.
[12] S. Robbins,et al. Problems in the quantitation of coronary arteriosclerosis. , 1966, The American journal of cardiology.
[13] D. Chakraborty. Image intensifier distortion correction. , 1987, Medical physics.
[14] E. Bolson,et al. Quantitative Coronary Arteriography: Estimation of Dimensions, Hemodynamic Resistance, and Atheroma Mass of Coronary Artery Lesions Using the Arteriogram and Digital Computation , 1977, Circulation.
[15] C A Mistretta,et al. Quantification techniques for dual-energy cardiac imaging. , 1989, Medical physics.
[16] M Moriuchi,et al. The reproducibility of intravascular ultrasound imaging in vitro. , 1990, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.
[17] H De Geest,et al. Intravascular ultrasound versus angiography for measurement of luminal diameters in normal and diseased coronary arteries. , 1994, American heart journal.
[18] J. J. Gerbrands,et al. Coronary Artery Dimensions from Cineangiograms-Methodology and Validation of a Computer-Assisted Analysis Procedure , 1984, IEEE Transactions on Medical Imaging.
[19] P D Clayton,et al. The effects of motion on quantitative vessel measurements. , 1985, Medical physics.
[20] Quantitative dual-energy coronary arteriography. , 1990, Investigative radiology.
[21] T Sandor,et al. Cine-densitometric measurement of coronary arterial stenoses. , 1979, Catheterization and cardiovascular diagnosis.
[22] S. Paulin,et al. Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms. , 1983, Circulation.
[23] K. Doi,et al. Image feature analysis and computer-aided diagnosis in digital radiography. 2. Computerized determination of vessel sizes in digital subtraction angiography. , 1987, Medical physics.
[24] P. Serruys,et al. Quantitative angiography during coronary angioplasty with a single angiographic view: a comparison of automated edge detection and videodensitometric techniques. , 1993, American Heart Journal.
[25] M J Davies,et al. Potential errors in the estimation of coronary arterial stenosis from clinical arteriography with reference to the shape of the coronary arterial lumen. , 1986, British heart journal.
[26] D B Plewes,et al. Quantitative digital subtraction angiography: two scanning techniques for correction of scattered radiation and veiling glare. Work in progress. , 1985, Radiology.
[27] K Doi,et al. Accurate analysis of blood vessel sizes and stenotic lesions using stereoscopic DSA system. , 1988, Investigative radiology.
[28] C A Mistretta,et al. Scatter-glare corrections in quantitative dual-energy fluoroscopy. , 1988, Medical physics.
[29] Yao-Jin Qian,et al. A digital filtration technique for scatter-glare correction based on thickness estimation , 1995, IEEE Trans. Medical Imaging.
[30] C M Grondin,et al. Discrepancies Between Cineangiographic and Postmortem Findings in Patients with Coronary Artery Disease and Recent Myocardial Revascularization , 1974, Circulation.