Developments in mechanical heart valve prosthesis

Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the performance of mechanical heart valves. The clinical performance of mechanical heart valves is also addressed. Efforts made in India in the development of mechanical heart valves are also discussed.

[1]  Hufnagel Ca,et al.  Surgical correction of aortic insufficiency. , 1954 .

[2]  V. Björk,et al.  A new tilting disc valve prosthesis. , 1969, Scandinavian journal of thoracic and cardiovascular surgery.

[3]  K B Chandran,et al.  Cavitation dynamics of mechanical heart valve prostheses. , 1994, Artificial organs.

[4]  M. Valiathan,et al.  Chitra heart valve: results of a multicenter clinical study. , 2001, The Journal of heart valve disease.

[5]  K. B. Chandran,et al.  Negative Pressure Transients with Mechanical Heart-Valve Closure: Correlation between In Vitro and In Vivo Results , 1998, Annals of Biomedical Engineering.

[6]  L. Cohn,et al.  Infection within a degenerated Starr-Edwards silicone rubber poppet in the aortic valve position. , 1984, The American journal of cardiology.

[7]  W. P. Nelson,et al.  Common cardiac prosthetic valves. Radiologic identification and associated complications. , 1977, JAMA.

[8]  P. Ribeiro,et al.  Antiplatelet drugs and the incidence of thromboembolic complications of the St. Jude Medical aortic prosthesis in patients with rheumatic heart disease. , 1986, The Journal of thoracic and cardiovascular surgery.

[9]  A. Krosnick DEATH DUE TO MIGRATION OF THE BALL FROM AN AORTIC-VALVE PROSTHESIS. , 1965, JAMA.

[10]  A. Wøien,et al.  An improved pivotal disc-type prosthetic heart valve. , 1979, Journal of the Oslo city hospitals.

[11]  W. Roberts,et al.  Choosing a substitute cardiac valve: type, size, surgeon. , 1976, The American journal of cardiology.

[12]  K. Chandran,et al.  Mechanical valve closing dynamics: Relationship between velocity of closing, pressure transients, and cavitation initiation , 2007, Annals of Biomedical Engineering.

[13]  V. Björk,et al.  The improved Björk-Shiley tilting disc valve prosthesis. , 1978, Scandinavian journal of thoracic and cardiovascular surgery.

[14]  C. V. Muraleedharan,et al.  Failure mode and effect analysis of Chitra heart valve prosthesis , 1995, Proceedings of the First Regional Conference, IEEE Engineering in Medicine and Biology Society and 14th Conference of the Biomedical Engineering Society of India. An International Meet.

[15]  M. Valiathan,et al.  Evaluation of materials for artificial heart valves , 1991 .

[16]  J. Copeland,et al.  Four-year experience with the CarboMedics valve: the North American experience. North American team of clinical investigators for the CarboMedics prosthetic heart valve. , 1994, The Annals of thoracic surgery.

[17]  G S Bhuvaneshwar,et al.  Development of the Chitra tilting disc heart valve prosthesis. , 1996, The Journal of heart valve disease.