Three-dimensional cellular-level imaging using full-field optical coherence tomography.

An ultrahigh-resolution full-field optical coherence tomography (OCT) system has been developed for cellular-level imaging of biological media. The system is based on a Linnik interference microscope illuminated with a tungsten halogen lamp, associated with a high-resolution CCD camera. En face tomographic images are produced in real time, with the best spatial resolution ever achieved in OCT (0.7 microm x 0.9 microm, axial x transverse). A shot-noise limited detection sensitivity of 80 dB can be reached with an acquisition time per image of 1 s. Images of animal ophthalmic biopsies and vegetal tissues are shown.

[1]  B E Bouma,et al.  Self-phase-modulated Kerr-lens mode-locked Cr:forsterite laser source for optical coherence tomography. , 1996, Optics letters.

[2]  J. Fujimoto,et al.  In vivo ultrahigh-resolution optical coherence tomography. , 1999, Optics letters.

[3]  J. Fujimoto,et al.  In vivo endoscopic optical biopsy with optical coherence tomography. , 1997, Science.

[4]  Andrew M. Rollins,et al.  High-speed full-field optical coherence microscopy , 1999, Photonics West - Biomedical Optics.

[5]  A. Boccara,et al.  Thermal-light full-field optical coherence tomography. , 2002, Optics letters.

[6]  Brett E. Bouma,et al.  In vivo cellular optical coherence tomography imaging , 1998, Nature Medicine.

[7]  David A. Jackson,et al.  Three dimensional OCT images from retina and skin. , 2000, Optics express.

[8]  D. Reitze,et al.  Noninvasive imaging by optical coherence tomography to monitor retinal degeneration in the mouse. , 2001, Investigative ophthalmology & visual science.

[9]  David A. Jackson,et al.  En-face coherence imaging using galvanometer scanner modulation. , 1998, Optics letters.

[10]  Adolf Friedrich Fercher Optical coherence tomography. , 1996 .

[11]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[12]  J G Fujimoto,et al.  High-resolution optical coherence tomographic imaging using a mode-locked Ti:Al(2)O(3) laser source. , 1995, Optics letters.

[13]  Qienyuan Zhou,et al.  Three-dimensional imaging of the human retina by high-speed optical coherence tomography. , 2003, Optics express.

[14]  Harald Sattmann,et al.  Histologic correlation of pig retina radial stratification with ultrahigh-resolution optical coherence tomography. , 2003, Investigative ophthalmology & visual science.

[15]  C K Hitzenberger,et al.  Dispersion effects in partial coherence interferometry: implications for intraocular ranging. , 1999, Journal of biomedical optics.

[16]  A. Fercher,et al.  Submicrometer axial resolution optical coherence tomography. , 2002, Optics letters.

[17]  J. Fujimoto,et al.  Optical coherence microscopy in scattering media. , 1994, Optics letters.

[18]  J. Fujimoto,et al.  Ultrahigh Resolution Optical Coherence Tomography for Quantitative Measurement of Retinal Architectural Morphology , 2002 .

[19]  W. Drexler Ultrahigh-resolution optical coherence tomography. , 2004, Journal of biomedical optics.

[20]  T. Chunkan Inconsistency of the constant constraint criterion in optical correlation pattern recognition. , 1995, Optics letters.

[21]  A. Boccara,et al.  High-resolution full-field optical coherence tomography with a Linnik microscope. , 2002, Applied optics.