Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions

The present study prospectively evaluated the diagnostic yield and safety of electromagnetic navigation-guided bronchoscopy biopsy, for small peripheral lung lesions in patients where standard techniques were nondiagnostic. The study was conducted in a tertiary medical centre on 40 consecutive patients considered unsuitable for straightforward surgery or computed tomography (CT)-guided transthoracic needle aspiration biopsy, due to comorbidities. The lung lesion diameter was mean±sem 23.5±1.5 mm and the depth from the visceral-costal pleura was 14.9±2 mm. Navigation was facilitated by an electromagnetic tracking system which could detect a position sensor incorporated into a flexible catheter advanced through a bronchoscope. Information obtained during bronchoscopy was superimposed on previously acquired CT data. Divergence between CT data and data obtained during bronchoscopy was calculated by the system's software as a measure of navigational accuracy. All but one of the target lesions was reached and the overall diagnostic yield was 62.5% (25–40). Diagnostic yield was significantly affected by CT-to-body divergence; yield was 77.2% when estimated divergence was ≤4 mm. Three pneumothoraces occurred and chest drainage was required in one case. Electromagnetic navigation-guided bronchoscopy has the potential to improve the diagnostic yield of transbronchial biopsies without additional fluoroscopic guidance, and may be useful in the early diagnosis of lung cancer, particularly in nonoperable patients.

[1]  G. Sideris,et al.  The role of transbronchial needle aspiration in the diagnosis of peripheral lung masses or nodules. , 1995, The European respiratory journal.

[2]  O S Miettinen,et al.  Early lung cancer action project: a summary of the findings on baseline screening. , 2001, The oncologist.

[3]  S. Gasparini,et al.  Integration of TBNA and TCNA in the diagnosis of peripheral lung nodules. Influence on staging. , 1999, Annali italiani di chirurgia.

[4]  F. Herth,et al.  Endobronchial ultrasound-guided transbronchial lung biopsy in fluoroscopically invisible solitary pulmonary nodules: a prospective trial. , 2006, Chest.

[5]  E. Fletcher,et al.  Flexible fiberoptic bronchoscopy and fluoroscopically guided transbronchial biopsy in the management of solitary pulmonary nodules. , 1982, The Western journal of medicine.

[6]  R. Ginsberg,et al.  Modern thirty-day operative mortality for surgical resections in lung cancer. , 1983, The Journal of thoracic and cardiovascular surgery.

[7]  K. Torrington,et al.  The utility of fiberoptic bronchoscopy in the evaluation of the solitary pulmonary nodule. , 1993, Chest.

[8]  R. Myles Transbronchial needle aspiration of peripheral masses. , 1984, The American review of respiratory disease.

[9]  Y. Ohno,et al.  CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules. , 2003, AJR. American journal of roentgenology.

[10]  F. Herth,et al.  Electromagnetic Navigation during Flexible Bronchoscopy , 2003, Respiration.

[11]  Feng Li,et al.  Mass screening for lung cancer with mobile spiral computed tomography scanner , 1998, The Lancet.

[12]  F. Martinez,et al.  Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. , 1996, Radiology.

[13]  T. Gildea,et al.  Electromagnetic navigation diagnostic bronchoscopy: a prospective study. , 2006, American journal of respiratory and critical care medicine.

[14]  T. McLoud,et al.  Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. , 1996, AJR. American journal of roentgenology.

[15]  D. Postma,et al.  Techniques in human airway inflammation: quantity and morphology of bronchial biopsy specimens taken by forceps of three sizes. , 1998, Chest.

[16]  Daniel Y Sze,et al.  CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. , 2003, Radiology.

[17]  K Katada,et al.  Radiation dosimetry at CT fluoroscopy: physician's hand dose and development of needle holders. , 1996, Radiology.

[18]  D. Cortese,et al.  Biopsy and brushing of peripheral lung cancer with fluoroscopic guidance. , 1979, Chest.

[19]  C. Williams,et al.  Radical radiotherapy for stage I/II non-small cell lung cancer in patients not sufficiently fit for or declining surgery (medically inoperable): a systematic review , 2001, Thorax.

[20]  A. Mehta,et al.  Radiation safety for health care workers in the bronchoscopy suite. , 1999, Clinics in chest medicine.

[21]  A. Ernst,et al.  Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: the first human study. , 2006, Chest.

[22]  Koichi Yamazaki,et al.  CT-guided transbronchial biopsy using an ultrathin bronchoscope with virtual bronchoscopic navigation. , 2004, Chest.

[23]  Levin Dc,et al.  Flexible Fiberoptic Bronchoscopy and Fluoroscopically Guided Transbronchial Biopsy in the Management of Solitary Pulmonary Nodules , 1982 .

[24]  S. Raab,et al.  Improving the quality of cytology diagnosis: root cause analysis for errors in bronchial washing and brushing specimens. , 2005, American journal of clinical pathology.

[25]  Douglas C McCrory,et al.  Performance characteristics of different modalities for diagnosis of suspected lung cancer: summary of published evidence. , 2003, Chest.

[26]  V Latrabe,et al.  Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. , 1999, AJR. American journal of roentgenology.

[27]  W. Baaklini,et al.  Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules. , 2000, Chest.

[28]  Anne-Marie Sykes,et al.  CT screening for lung cancer: five-year prospective experience. , 2005, Radiology.

[29]  O. Miettinen,et al.  Computed tomographic screening for lung cancer: the relationship of disease stage to tumor size. , 2006, Archives of internal medicine.

[30]  J. Luketich,et al.  Radiofrequency ablation of pulmonary malignant tumors in nonsurgical candidates. , 2003, The Journal of thoracic and cardiovascular surgery.

[31]  R. Audisio,et al.  Choices in the management of asymptomatic lung nodules in the elderly. , 2004, Surgical oncology.

[32]  G. Byrnes,et al.  Validity of the Assessment of Quality of Life (AQoL) utility instrument in patients with operable and inoperable lung cancer. , 2006, Lung cancer.

[33]  P. Kvale,et al.  Diagnostic accuracy in peripheral lung lesions. Factors predicting success with flexible fiberoptic bronchoscopy. , 1979, Chest.

[34]  H. Feußner,et al.  Electromagnetic catheter navigation during bronchoscopy: validation of a novel method by conventional fluoroscopy. , 2005, Chest.

[35]  R. Shiner,et al.  Bronchoscopic evaluation of peripheral lung tumours. , 1988, Thorax.