Development of disposable amperometric sulfur dioxide biosensors based on screen printed electrodes.

The possibility of developing amperometric biosensors for the measurement of SO(2) in flowing gas streams has been examined. Screen-printed carbon electrodes (SPCEs) were tailored with the enzyme sulfite oxidase and cytochrome c and the response is generated through the resulting enzymatic and electrocatalytic reactions involving SO(3)(2-), formed when SO(2) gas is dissolved in the supporting electrolyte. Two methods of integrating the enzyme and cytochrome c with the SPCE were investigated. In one design (b-type biosensor), the components were mixed thoroughly with the same ink used to produce the SPCEs, then the modified ink was spread over the working electrode. In the second approach the bio-components were dissolved in the supporting electrolyte and simply deposited on top of the transducer (s-type biosensor). Both devices gave linear responses over the range 4--50 ppm but the sensitivity of the s-type was approximately twice that of the b-type biosensor. In addition, the time taken to reach 90% of the maximum response (t(90%)) was 110 s for the s-type biosensor compared with 200 s for the b-type biosensor. These studies illustrate the successful use of biosensors for the detection of sulfur dioxide at the relatively low potential of +0.3 V versus Ag.AgCl and should provide useful alternatives for decentralised environmental studies.

[1]  H. Mottola,et al.  Studies with a sulfite oxidase-modified carbon paste electrode for detection/determination of sulfite ion and SO2(g) in continuous-flow systems , 1990 .

[2]  John P. Hart,et al.  Chemically modified, screen-printed carbon electrodes , 1992 .

[3]  T. Yao,et al.  Simultaneous determination of sulfite and phosphate in wine by means of immobilized enzyme reactions and amperometric detection in a flow-injection system. , 1994, Talanta.

[4]  M. Tayanç,et al.  An assessment of spatial and temporal variation of sulfur dioxide levels over Istanbul, Turkey. , 2000, Environmental pollution.

[5]  John P. Hart,et al.  Development of an amperometric sulfite biosensor based on sulfite oxidase with cytochrome c, as electron acceptor, and a screen-printed transducer , 2000 .

[6]  D. Krochmal,et al.  Measurements of nitrogen dioxide and sulphur dioxide concentrations in urban and rural areas of Poland using a passive sampling method. , 1997, Environmental pollution.

[7]  John P. Hart,et al.  Voltammetric and amperometric studies of selected thiols and dimethyldisulfide using a screen‐printed carbon electrode modified with cobalt phthalocyanine: Studies towards a gas sensor , 1996 .

[8]  J. Hart,et al.  A disposable amperometric gas sensor for sulphur-containing compounds based on a chemically modified screen printed carbon electrode coated with a hydrogel , 1997 .

[9]  J. Hart,et al.  Direct electrochemistry of cytochrome c at plain and membrane modified screen-printed carbon electrodes , 2001 .

[10]  J. Hart,et al.  Electrocatalytic, diffusional and analytical characteristics of a cobalt phthalocyanine modified, screen-printed, amperometric gas sensor for propanethiol , 1997 .

[11]  A. Turner,et al.  Carbon monoxide :acceptor oxidoreductase from Pseudomonas thermocarboxydovorans strain C2 and its use in a carbon monoxide sensor , 1984 .