Magnetic resonance fluoroscopy using spirals with variable sampling densities

The imaging of dynamic processes in the body is of considerable interest in interventional examinations as well as kinematic studies, and spiral imaging is a fast magnetic resonance imaging technique ideally suited for such fluoroscopic applications. In this manuscript, magnetic resonance fluoroscopy pulse sequences in which interleaved spirals are used to continuously acquire data and reconstruct one movie frame for each repetition time interval are implemented. For many applications, not all of k‐space needs to be updated each frame, and nonuniform k‐space sampling can be used to exploit this rapid imaging strategy by allowing variable update rates for different spatial frequencies. Using the appropriate reconstruction algorithm, the temporal updating rate for each spatial frequency is effectively proportional to the corresponding k‐space sampling density. Results from a motion phantom as well as in in vivo gadolinium diethylenetriaminopentaacetic acid (Gd‐DTPA) bolus tracking studies in a rat model demonstrate the high temporal resolution achievable using these techniques as well as the tradeoffs available with nonuniform sampling densities. This paper focuses on the acquisition of real‐time dynamic information, and all images presented are reconstructed retrospectively. The issues of real‐time data reconstruction and display are not addressed.

[1]  P M Jakob,et al.  Scan time reduction in snapshot flash MRI , 1992, Magnetic resonance in medicine.

[2]  R. Bracewell The Fourier Transform and Its Applications , 1966 .

[3]  Re Hendrick Sunday afternoon grand ballroom AB plenary symposia 004–006. Fast/Ultrafast imaging , 1991 .

[4]  Henry Stark,et al.  Spiral Sampling in Magnetic Resonance Imaging-The Effect of Inhomogeneities , 1987, IEEE Transactions on Medical Imaging.

[5]  Douglas C. Noll,et al.  Deblurring for non‐2D fourier transform magnetic resonance imaging , 1992, Magnetic resonance in medicine.

[6]  D Matthaei,et al.  Rapid three-dimensional MR imaging using the FLASH technique. , 1986, Journal of computer assisted tomography.

[7]  R Turner,et al.  Snapshot head imaging at 0.5 T using the echo planar technique , 1988, Magnetic resonance in medicine.

[8]  Christopher J. Hardy,et al.  Broadband nuclear magnetic resonance pulses with two‐dimensional spatial selectivity , 1989 .

[9]  R. Rzedzian,et al.  Instant images of the body by magnetic resonance , 1987, Magnetic resonance in medicine.

[10]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[11]  J N Lee,et al.  MR fluoroscopy: Technical feasibility , 1988, Magnetic resonance in medicine.

[12]  R J Ordidge,et al.  Real time movie images by NMR. , 1982, The British journal of radiology.

[13]  J. Pauly,et al.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients. , 1991, IEEE transactions on medical imaging.

[14]  Kim Butts,et al.  Analysis of flow effects in echo‐planar imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[15]  W. E. Glenn,et al.  Imaging system design based on psychophysical data , 1985 .

[16]  P Webb,et al.  Rapid, fully automatic, arbitrary‐volume in vivo shimming , 1991, Magnetic resonance in medicine.

[17]  S J Riederer,et al.  Real‐time MR fluoroscopic data acquisition and image reconstruction , 1989, Magnetic resonance in medicine.

[18]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[19]  J N Lee,et al.  MR fluoroscopy: initial clinical studies. , 1989, Radiology.