A dynamic gain-scheduled ventilation control system for a subway station based on outdoor air quality conditions

Abstract Within subway stations, the use of a mechanical ventilation system is a common strategy for improving the indoor air quality (IAQ). These ventilation systems use outdoor air to dilute pollutants on the subway platforms. However, a fixed fan speed in manual subway station ventilation systems does not consider variations in IAQ dynamics caused by disturbances yielded by the outdoor air quality (OAQ). Since the IAQ in subway stations has become a major public health concern, this study aims to analyze the IAQ dynamics at different OAQ conditions to design a new dynamic ventilation control system. The proposed method implemented a Gain Scheduling control strategy over OAQ variations at the D-Subway Station in the Seoul metropolitan area. A set of one feedback (FB) and two feedforward (FF) controllers was implemented. The results showed that the proposed control system tuned with the internal model control (IMC) method achieved an energy saving of 9% in comparison to the manual ventilation system. It was estimated a decrease in energy consumption of 158 kWh/day, representing an emission reduction of 268 kgCO2/day. Following, an energy cost reduction of 4325 USD yearly was estimated. Additionally, the indoor particulate matter level is maintained below a control limit considered to be unhealthy for sensitive groups (150 μg/m3).

[1]  In-Beum Lee,et al.  Process Identification and PID Control , 2009 .

[2]  Richard D. Braatz,et al.  Indoor air quality control for improving passenger health in subway platforms using an outdoor air quality dependent ventilation system , 2015 .

[3]  L. Ljung Prediction error estimation methods , 2002 .

[4]  Yong-Seung Chung,et al.  On the occurrence of yellow sand and atmospheric loadings , 1996 .

[5]  Rajnish K. Calay,et al.  A hybrid energy efficient building ventilation system , 2013 .

[6]  Jeong Tai Kim,et al.  Monitoring and prediction of indoor air quality (IAQ) in subway or metro systems using season dependent models , 2012 .

[7]  M Tabarra,et al.  DESIGN OF A MODERN SUBWAY VENTILATION SYSTEM , 2004 .

[8]  You Shi-jun,et al.  A New System to Reduce Air Pollution in Metro Platform , 2011 .

[9]  Daniel Weisser,et al.  A guide to life-cycle greenhouse gas (GHG) emissions from electric supply technologies , 2007 .

[10]  María Cruz Minguillón,et al.  Subway platform air quality: Assessing the influences of tunnel ventilation, train piston effect and station design , 2014 .

[11]  Kamran Iqbal,et al.  PID controller tuning for the first-order-plus-dead-time process model via Hermite-Biehler theorem. , 2005, ISA transactions.

[12]  Jeong Tai Kim,et al.  Predictive monitoring and diagnosis of periodic air pollution in a subway station. , 2010, Journal of hazardous materials.

[13]  Soon-Bark Kwon,et al.  Indoor environment and passengers’ comfort in subway stations in Seoul , 2016 .

[14]  Zhao Yang,et al.  Research on frequency conversion technology of metro station's ventilation and air-conditioning system , 2014 .

[15]  Alberto Giretti,et al.  Model predictive energy control of ventilation for underground stations , 2016 .

[16]  ChangKyoo Yoo,et al.  Data-driven prediction model of indoor air quality in an underground space , 2010 .

[17]  Thomas F. Edgar,et al.  Process Dynamics and Control , 1989 .

[18]  ChangKyoo Yoo,et al.  Online monitoring and interpretation of periodic diurnal and seasonal variations of indoor air pollutants in a subway station using parallel factor analysis (PARAFAC) , 2014 .

[19]  Hongbo Fu,et al.  Characteristics and chemical compositions of particulate matter collected at the selected metro stations of Shanghai, China. , 2014, The Science of the total environment.

[20]  Heshmat A. Aglan,et al.  Effect of mechanically induced ventilation on the indoor air quality of building envelopes , 2010 .

[21]  Lei He,et al.  Investigation of air pollution of Shanghai subway stations in ventilation seasons in terms of PM2.5 and PM10 , 2017, Toxicology and industrial health.

[22]  John Palmer,et al.  The effect of external atmospheric pollution on indoor air quality: A pilot study , 1998 .

[23]  ChangKyoo Yoo,et al.  Multi-objective optimization of indoor air quality control and energy consumption minimization in a subway ventilation system , 2013 .

[24]  M. Minguillón,et al.  Factors controlling air quality in different European subway systems. , 2016, Environmental research.

[25]  Richard D. Braatz,et al.  Economical control of indoor air quality in underground metro station using an iterative dynamic programming-based ventilation system , 2016 .

[26]  ChangKyoo Yoo,et al.  Gain scheduling based ventilation control with varying periodic indoor air quality (IAQ) dynamics for healthy IAQ and energy savings , 2017 .

[27]  D. Dockery,et al.  Health Effects of Fine Particulate Air Pollution: Lines that Connect , 2006, Journal of the Air & Waste Management Association.

[28]  Monjur Mourshed,et al.  Forecasting methods in energy planning models , 2018 .