Automated fetal cardiac valve movement detection for modified myocardial performance index calculation

The Modified Myocardial Performance Index (Mod-MPI) is becoming an important index in fetal cardiac function evaluation. However, the current method for Mod-MPI calculation can be time-consuming and demonstrates poor inter-operator repeatability. This paper presents an automated method for detecting the opening and closing events of fetal cardiac valves with the aim of automating the Mod-MPI calculation. Fifty-four Doppler ultrasound images, showing blood inflow and outflow for the left ventricle, are analyzed to attempt to automatically detect the timings of a total of 905 opening and closing events for both aortic and mitral valves. Timings are found according to the morphological characteristics of waveforms as well as intensity information of images. The proposed method can detect the four valve movement events with high sensitivity (95.60-98.64%) and precision (96.85-100.00%). Results are verified by comparison with manual annotation of same images from an expert.

[1]  D. Friedman,et al.  Fetal cardiac function assessed by Doppler myocardial performance index (Tei Index) , 2003, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[2]  J B Seward,et al.  Noninvasive Doppler-derived myocardial performance index: correlation with simultaneous measurements of cardiac catheterization measurements. , 1997, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[3]  Marie-Josée Raboisson,et al.  Measuring left ventricular myocardial performance index in fetuses. , 2003, The American journal of cardiology.

[4]  A J Tajik,et al.  Doppler index combining systolic and diastolic myocardial performance: clinical value in cardiac amyloidosis. , 1996, Journal of the American College of Cardiology.

[5]  F. Cetta,et al.  Quantitative Assessment of Fetal Ventricular Function: Establishing Normal Values of the Myocardial Performance Index in the Fetus , 2001, Echocardiography.

[6]  António dos Anjos,et al.  Bi-Level Image Thresholding - A Fast Method , 2008, BIOSIGNALS.

[7]  C. Tei,et al.  New non-invasive index for combined systolic and diastolic ventricular function. , 1995, Journal of cardiology.

[8]  E. Gratacós,et al.  A modified myocardial performance (Tei) index based on the use of valve clicks improves reproducibility of fetal left cardiac function assessment , 2005, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[9]  N. Meriki,et al.  Fetal left modified myocardial performance index: technical refinements in obtaining pulsed‐Doppler waveforms , 2012, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[10]  M. Ishii,et al.  Serial evaluation for myocardial performance in fetuses and neonates using a new Doppler index , 1999, Pediatrics international : official journal of the Japan Pediatric Society.

[11]  A J Tajik,et al.  Doppler echocardiographic index for assessment of global right ventricular function. , 1996, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[12]  Marimuthu Palaniswami,et al.  Automated Identification of fetal cardiac valve timings , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[13]  N Meriki,et al.  Reproducibility of constituent time intervals of right and left fetal modified myocardial performance indices on pulsed Doppler echocardiography: a short report , 2012, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[14]  H. Yoon,et al.  Feasibility of using Auto Mod‐MPI system, a novel technique for automated measurement of fetal modified myocardial performance index , 2014, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[15]  古田泰大,et al.  Image processing method and image processing apparatus , 2010 .

[16]  N. Meriki,et al.  Development of Australian Reference Ranges for the Left Fetal Modified Myocardial Performance Index and the Influence of Caliper Location on Time Interval Measurement , 2012, Fetal Diagnosis and Therapy.

[17]  J C Huhta,et al.  Fetal congestive heart failure: correlation of Tei-Index and Cardiovascular-Score , 2001, Journal of perinatal medicine.