Wang Koch-adjusted axial length in SRK/T formula for ocular biometry in high myopia: a prospective study

Background: The aim of this study was to prospectively assess refractive results of cataract surgery in highly myopic eyes using the SRKT formula and Wang Koch-adjusted axial length. Material and methods: Prospectively, we recruited consecutive candidates for cataract surgery having an axial length equal to 27 mm and longer. We performed biometry by using Wang and Koch-adjusted axial length applied to the SRKT formula. The main outcome measures were: mean of refractive error, mean of absolute refractive error, and percentage of eyes that achieved a refractive error of ± 0.5D and ± 1D. Results: Fifteen eyes of nine patients were involved in the study. The mean refractive error was -0.01D ± 0.4D, and the mean absolute refractive error was + 0.35D ± 0.20D. Refractive errors of ± 0.5D and ± 1D were achieved, respectively, in 86.6% and in 100% of eyes. Conclusions: Wang Koch’s axial length adjustment applied to the SRKT formula is a reliable alternative in high myopic cataract patients.

[1]  Mitchell P. Weikert,et al.  Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia. , 2019, Journal of cataract and refractive surgery.

[2]  Guohua Deng,et al.  Accuracy of the refractive prediction determined by intraocular lens power calculation formulas in high myopia , 2019, Indian journal of ophthalmology.

[3]  D. Koch,et al.  Modified axial length adjustment formulas in long eyes. , 2018, Journal of cataract and refractive surgery.

[4]  Haotian Lin,et al.  Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta‐analysis , 2018, Clinical & experimental ophthalmology.

[5]  J. Holladay,et al.  Accuracy of Intraocular Lens Calculation Formulas. , 2017, Ophthalmology.

[6]  D. Koch,et al.  Protocols for Studies of Intraocular Lens Formula Accuracy. , 2016, American journal of ophthalmology.

[7]  D. Koch,et al.  Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: Comparison of formulas and methods , 2015, Journal of cataract and refractive surgery.

[8]  Muka Moriyama,et al.  Evaluation of refractive error after cataract surgery in highly myopic eyes , 2013, International Ophthalmology.

[9]  U. Stenevi,et al.  Aiming for emmetropia after cataract surgery: Swedish National Cataract Register study , 2012, Journal of cataract and refractive surgery.

[10]  Thomas Kohnen,et al.  Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm , 2011, Journal of cataract and refractive surgery.

[11]  S. Tuft,et al.  Phacoemulsification in eyes with extreme axial myopia , 2009, Journal of cataract and refractive surgery.

[12]  H. Hayashi,et al.  Optimum target refraction for highly and moderately myopic patients after monofocal intraocular lens implantation , 2007, Journal of cataract and refractive surgery.

[13]  J. Holladay,et al.  Intraocular lens power calculations in patients with extreme myopia. , 2000, Journal of cataract and refractive surgery.