Wearable Accelerometer System for Measuring the Temporal Parameters of Gait

A small and wireless accelerometer system was developed for the estimation of temporal gait parameters. The new system was built using two 3-axis accelerometers. Measurement's accuracy was assessed using as a criterion standard provided by foot switches. To assess the consistency of this system, estimates of heel contact and toe off time based on accelerometers and those based on footswitches were compared for 20 steps from 8 individual healthy subjects. Accelerometers and footswitches had high consistency in the temporal gait parameters. The stance, swing, single support, and double support time of gait cycle revealed ICCs values of 0.95, 0.93, 0.86, and 0.75 on the right and 0.96, 0.86, 0.93, 0.84 on the left, respectively. Therefore, this system proved to be a reliable tool for identification of temporal gait parameters.

[1]  C. Sackley,et al.  The intra-rater reliability of the Balance Performance Monitor when measuring sitting symmetry and weight-shift activity after stroke in a community setting , 2005, Clinical rehabilitation.

[2]  G M Lyons,et al.  Accelerometers in rehabilitation medicine for older adults. , 2005, Age and ageing.

[3]  B. Dobkin,et al.  Reliability and Validity of Bilateral Thigh and Foot Accelerometry Measures of Walking in Healthy and Hemiparetic Subjects , 2006, Neurorehabilitation and neural repair.

[4]  A. L. Evans,et al.  Recording accelerations in body movements , 2006, Medical and Biological Engineering and Computing.

[5]  G. Harris,et al.  Foot pressure distribution during walking and shuffling. , 1991, Archives of physical medicine and rehabilitation.

[6]  B. Auvinet,et al.  Reference data for normal subjects obtained with an accelerometric device. , 2002, Gait & posture.

[7]  K. Aminian,et al.  Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty , 1999, Medical & Biological Engineering & Computing.

[8]  A. Hof,et al.  Assessment of spatio-temporal gait parameters from trunk accelerations during human walking. , 2003, Gait & posture.

[9]  Jeffrey M. Hausdorff,et al.  Footswitch system for measurement of the temporal parameters of gait. , 1995, Journal of biomechanics.

[10]  Z O Abu-Faraj,et al.  A Holter-type microprocessor-based rehabilitation instrument for acquisition and storage of plantar pressure data in children with cerebral palsy. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[11]  L. Portney,et al.  Foundations of Clinical Research , 1993 .

[12]  Z O Abu-Faraj,et al.  A Holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data. , 1997, Journal of rehabilitation research and development.

[13]  M Akay,et al.  Fractal dynamics of body motion in post-stroke hemiplegic patients during walking , 2004, Journal of neural engineering.