Electrochemical sensing of ascorbic acid by a novel manganese(III) complex

Abstract [Mn(Phimp) 2 ](ClO 4 ) complex was utilized for the electrochemical sensing of ascorbic acid (AA) with disposable gold-based compact disks (G-CDs) electrodes. On the Mn(III) complex-modified electrode the oxidation of AA can be carried out at lower potential and with higher current, due to the electrocatalytic activity of the Mn(III) complex layer. Furthermore, it exhibited an excellent selectivity to AA in the presence of possible interference compounds. The electrocatalytic mechanism was postulated to be governed by the Mn(III)/Mn(II) redox couple.

[1]  E. Richter,et al.  Gold electrodes from recordable CDs , 2000, Analytical chemistry.

[2]  Qiulei Ren,et al.  Study of the catalytic electro-oxidation of ascorbic acid on an electrode modified by macrocyclic compounds of Fe(III), Mn(III), Ni(II), and Co(II) with TBP , 2001 .

[3]  Protiva Rani Roy,et al.  Simultaneous electroanalysis of dopamine and ascorbic acid using poly (N,N-dimethylaniline)-modified electrodes. , 2003, Bioelectrochemistry.

[4]  Sejin Park,et al.  Nonenzymatic glucose detection using mesoporous platinum. , 2003, Analytical chemistry.

[5]  Pramod Kumar,et al.  Stabilization of Mn(II) and Mn(III) in mononuclear complexes derived from tridentate ligands with N2O donors: synthesis, crystal structure, superoxide dismutase activity and DNA interaction studies. , 2010, Journal of inorganic biochemistry.

[6]  Jinghong Ma,et al.  Zeolite-encapsulated M(Co, Fe, Mn)(SALEN) complexes modified glassy carbon electrodes and their application in oxygen reduction , 2010 .

[7]  Xiao-hua Li,et al.  Amperometric Biosensor Based on Immobilization Acetylcholinesterase on Manganese Porphyrin Nanoparticles for Detection of Trichlorfon with Flow‐Injection Analysis System , 2007 .

[8]  R. Seeber,et al.  Polythiophene Derivative Conducting Polymer Modified Electrodes and Microelectrodes for Determination of Ascorbic Acid. Effect of Possible Interferents , 2002 .

[9]  K. Vytras,et al.  (Bio)sensors based on manganese dioxide-modified carbon substrates: retrospections, further improvements and applications. , 2004, Talanta.

[10]  M. A. Alonso-Lomillo,et al.  Recent developments in the field of screen-printed electrodes and their related applications. , 2007, Talanta.

[11]  T. Ohsaka,et al.  Electroanalysis of ascorbate and dopamine at a gold electrode modified with a positively charged self-assembled monolayer , 2001 .

[12]  Dik‐Lung Ma,et al.  Transition metal complexes as electrocatalysts : Development and applications in electro-oxidation reactions , 2007 .

[13]  Martin Bartoš,et al.  AMPEROMETRIC DETERMINATION OF GLUCOSE WITH AN MnO2 AND GLUCOSE OXIDASE BULK-MODIFIED SCREEN-PRINTED CARBON INK BIOSENSOR , 2001 .

[14]  H. H. Monfared,et al.  Electrocatalytic oxidation of hydrazine using glassy carbon electrode modified with carbon nanotube and terpyridine manganese(II) complex , 2010 .

[15]  D. Patel,et al.  A Spectrophotometric Determination of Ascorbic Acid , 2005 .

[16]  M. del Valle,et al.  Automated SIA e‐Tongue Employing a Voltammetric Biosensor Array for the Simultaneous Determination of Glucose and Ascorbic Acid , 2006 .

[17]  Shen-ming Chen,et al.  The Interaction of Water‐Soluble Manganese Porphyrins with DNA Films and Their Electrocatalytic Properties with Hydrazine , 2005 .