Classification algorithms enhance the discrimination of glaucoma from normal eyes using high-definition optical coherence tomography.

PURPOSE To evaluate the diagnostic performance of classification algorithms based on Linear Discriminant Analysis (LDA) and Classification And Regression Tree (CART) methods, compared with optic nerve head (ONH) and retinal nerve fiber layer (RNFL) parameters measured by high-definition optical coherence tomography (Cirrus HD-OCT) for discriminating glaucoma subjects. METHODS Consecutive glaucoma subjects (Training data = 184; Validation data = 102) were recruited from an eye center and normal subjects (n = 508) from an ongoing Singaporean Chinese population-based study. ONH and RNFL parameters were measured using a 200 × 200 scan protocol. LDA and CART were computed and areas under the receiver operating characteristic curve (AUC) compared. RESULTS Average RNFL thickness (AUC 0.92, 95% confidence interval [CI] 0.91, 0.93), inferior RNFL thickness (AUC 0.92, 95% CI 0.91, 0.93), vertical cup-disc ratio (AUC 0.91, 95% CI 0.90, 0.92) and rim area/disc area ratio (AUC 0.90, 95% CI 0.86, 0.93) discriminated glaucoma better than other parameters (P ≤ 0.033). LDA (AUC 0.96, 95% CI 0.95, 0.96) and CART (0.98, 95% CI 0.98, 0.99) outperformed all parameters for diagnostic accuracy (P ≤ 0.005). Misclassification rates in LDA (8%) and CART (5.6%) were found to be low. The AUC of LDA for the validation data was 0.98 (0.95, 0.99) and CART was 0.99 (0.99, 0.994). CART discriminated mild glaucoma from normal better than LDA (AUC 0.94 vs. 0.99, P < 0.0001). CONCLUSIONS Classification algorithms based on LDA and CART can be used in HD-OCT analysis for glaucoma discrimination. The CART method was found to be superior to individual ONH and RNFL parameters for early glaucoma discrimination.

[1]  T. W. Anderson An Introduction to Multivariate Statistical Analysis , 1959 .

[2]  Discriminating ability of optical coherence tomography data in staging glaucomatous damage. , 2009, Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.

[3]  A. Mansour Racial variation of optic disc size. , 1991, Ophthalmic research.

[4]  F. Medeiros,et al.  Effect of disease severity on the performance of Cirrus spectral-domain OCT for glaucoma diagnosis. , 2010, Investigative ophthalmology & visual science.

[5]  Robert N. Weinreb,et al.  Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study. , 2010, Ophthalmology.

[6]  Michael I. Seider,et al.  Optic Disk Size Variability Between African, Asian, White, Hispanic, and Filipino Americans Using Heidelberg Retinal Tomography , 2009, Journal of glaucoma.

[7]  Teresa C. Chen,et al.  Spectral domain optical coherence tomography in glaucoma: qualitative and quantitative analysis of the optic nerve head and retinal nerve fiber layer (an AOS thesis). , 2009, Transactions of the American Ophthalmological Society.

[8]  Douglas R. Anderson,et al.  Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes. , 2011, Ophthalmology.

[9]  Ningli Wang,et al.  Evaluation of optic nerve head and retinal nerve fiber layer in early and advance glaucoma using frequency-domain optical coherence tomography , 2010, Graefe's Archive for Clinical and Experimental Ophthalmology.

[10]  C. Girkin,et al.  Artifacts on the Optic Nerve Head Analysis of the Optical Coherence Tomography in Glaucomatous and Nonglaucomatous Eyes , 2009, Journal of glaucoma.

[11]  R. Pandey,et al.  Evaluation of optical coherence tomography and heidelberg retinal tomography parameters in detecting early and moderate glaucoma. , 2007, Investigative ophthalmology & visual science.

[12]  Kouros Nouri-Mahdavi,et al.  Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma. , 2006, American journal of ophthalmology.

[13]  F. Medeiros,et al.  Effect of disease severity and optic disc size on diagnostic accuracy of RTVue spectral domain optical coherence tomograph in glaucoma. , 2011, Investigative ophthalmology & visual science.

[14]  Jing He,et al.  Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: analysis of the retinal nerve fiber layer map for glaucoma detection. , 2010, Ophthalmology.

[15]  P. Mitchell,et al.  Methodology of the Singapore Indian Chinese Cohort (SICC) Eye Study: Quantifying ethnic variations in the epidemiology of eye diseases in Asians , 2009, Ophthalmic epidemiology.

[16]  C. Kim,et al.  Optic nerve head topographic measurements and retinal nerve fiber layer thickness in physiologic large cups. , 2005, Korean journal of ophthalmology : KJO.

[17]  Christopher Kai-shun Leung,et al.  Analysis of retinal nerve fiber layer and optic nerve head in glaucoma with different reference plane offsets, using optical coherence tomography. , 2005, Investigative ophthalmology & visual science.

[18]  N. Balakrishna,et al.  Correlation Between Peripapillary Retinal Nerve Fiber Layer Thickness and Optic Nerve Head Parameters Using Spectral Domain Optical Coherence Tomography , 2010, Journal of glaucoma.

[19]  Robert Tibshirani,et al.  The Elements of Statistical Learning: Data Mining, Inference, and Prediction, 2nd Edition , 2001, Springer Series in Statistics.

[20]  R. Susanna,et al.  Comparison of Quantitative Imaging Devices and Subjective Optic Nerve Head Assessment by General Ophthalmologists to Differentiate Normal From Glaucomatous Eyes , 2008, Journal of glaucoma.

[21]  Gadi Wollstein,et al.  Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy. , 2003, American journal of ophthalmology.

[22]  Diagnostic ability of a linear discriminant function for optic nerve head parameters measured with optical coherence tomography for perimetric glaucoma , 2010, Eye.

[23]  Lingling Wu,et al.  Optic disc analysis with Heidelberg Retina Tomography III in glaucoma with unilateral visual field defects , 2010, Japanese Journal of Ophthalmology.

[24]  Joel S Schuman,et al.  Optic Nerve Head (ONH) Topographic Analysis by Stratus OCT in Normal Subjects: Correlation to Disc Size, Age, and Ethnicity , 2009, Journal of glaucoma.

[25]  C. Cheung,et al.  Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography a study on diagnostic agreement with Heidelberg Retinal Tomograph. , 2010, Ophthalmology.

[26]  Samin Hong,et al.  Reproducibility of peripapillary retinal nerve fiber layer thickness with spectral domain cirrus high-definition optical coherence tomography in normal eyes , 2010, Japanese Journal of Ophthalmology.

[27]  F. Medeiros,et al.  Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. , 2005, American journal of ophthalmology.