Calculation and measurement of mean room surface exitance: The accuracy evaluation

Cuttle proposed mean room surface exitance as a new interior lighting design methodology, which focuses on lit appearance rather than visual performance. A few challenges exist, among which, an easy calculation method and a practical measurement strategy are two important aspects. Cuttle has developed a simplified equation for mean room surface exitance calculation and proposed that mean room surface exitance can be estimated by measuring indirect corneal illuminance from a position that ‘brings most of the space into view’; however, no solid proof was provided. In this work, first, we demonstrate that the simplified equation is reasonably accurate by comparing its predictions with the results based on numerical simulation of a wide range of surface reflectance combinations. Two luminaire locations, which are carefully selected to have the same input to the simplified equation but leading to very different surface exitance distributions, are adopted to further verify the simplified equation; second, through a theoretical analysis and numerical simulation, we show that both indirect corneal illuminance and indirect cylindrical illuminance vary significantly with the measurement location and can be very different from mean room surface exitance. Therefore, we conclude that the method of measuring mean room surface exitance suggested in prior publications may not provide accurate results.

[1]  Gregory J. Ward,et al.  The RADIANCE lighting simulation and rendering system , 1994, SIGGRAPH.

[2]  G. W. Larson,et al.  Rendering with radiance - the art and science of lighting visualization , 2004, Morgan Kaufmann series in computer graphics and geometric modeling.

[3]  C. Cuttle,et al.  Lighting by Design , 2003 .

[4]  C. Cuttle Towards the third stage of the lighting profession , 2010 .

[5]  Jan L.M. Hensen,et al.  State of the art in lighting simulation for building science: a literature review , 2012 .

[6]  C. Cuttle,et al.  A new direction for general lighting practice , 2013 .

[7]  Peter Boyce,et al.  LRT symposium ‘Better metrics for better lighting’ – a summary , 2014 .

[8]  P Raynham,et al.  Room lighting in the absence of a defined visual task and the impact of mean room surface exitance , 2016 .

[9]  J. Duff Research Note: On the magnitude of error in the calculation of mean room surface exitance , 2016 .

[10]  G. Antonutto,et al.  On the calculation and measurement of mean room surface exitance , 2016 .

[11]  Qi Dai,et al.  A proposed lighting-design space: circadian effect versus visual illuminance , 2017 .

[12]  Qi Dai,et al.  Spectral optimisation and a novel lighting-design space based on circadian stimulus , 2018 .

[13]  Minchen Wei,et al.  The impact of room surface reflectance on corneal illuminance and rule-of-thumb equations for circadian lighting design , 2018, Building and Environment.

[14]  C Cuttle,et al.  A fresh approach to interior lighting design: The design objective – direct flux procedure , 2018 .