Amperometric biosensor based on tyrosinase immobilized on a boron-doped diamond electrode.

A novel method has been developed to immobilize tyrosinase onto the surface of boron-doped diamond (BDD) electrode. The hydrogen-terminated BDD (HBDD) surface was first functionalized by photochemically linking vinyl groups of allylamine, producing covalently linked amine-terminated active BDD (ABDD) surface. Then the tyrosinase was immobilized onto the ABDD surface by carbodiimide coupling reaction. The amperometric response was measured as a function of concentration of phenolic compounds in 0.1M phosphate buffer solution (pH 6.5). The tyrosinase-modified ABDD electrode gave a linear response range of 1-175, 1-200 and 1-200 microM and sensitivity of 80.0, 181.4 and 110.0 mA M(-1)cm(-2) for phenol, p-cresol, 4-chlorophenol, respectively. Moreover, selective detection of dopamine (DA) in the presence of ascorbic acid (AA) has been demonstrated with the tyrosinase-modified ABDD electrode. Linearity was observed within the range of 5-120 microM. The above enzyme electrode could maintain 90% of its original activity after intermittent use for 1 month when storing in a dry state at 4 degrees C.

[1]  S. Campuzano,et al.  Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors , 2003 .

[2]  J. Butler,et al.  Electrochemical study of diamond thin films in neutral and basic solutions of nitrate , 1996 .

[3]  Hongwu Zhang,et al.  Layer-by-layer assembled carbon nanotubes for selective determination of dopamine in the presence of ascorbic acid. , 2004, Biosensors & bioelectronics.

[4]  K. Kaneto,et al.  A new tyrosinase biosensor based on covalent immobilization of enzyme on N-(3-aminopropyl) pyrrole polymer film , 2005 .

[5]  Itaru Honma,et al.  Electrochemical biosensor based on protein-polysaccharide hybrid for selective detection of nanomolar dopamine metabolite of 3,4-dihydroxyphenylacetic acid (DOPAC) , 2005 .

[6]  Dennis C. Johnson,et al.  Electrochemical removal of phenolic films from a platinum anode , 1979 .

[7]  A. Fujishima,et al.  Electrochemical Incineration of Organic Pollutants on Boron-Doped Diamond Electrode. Evidence for Direct Electrochemical Oxidation Pathway , 2003 .

[8]  A. Fujishima,et al.  Electron transfer from diamond electrodes to heme peptide and peroxidase. , 2000, Analytical chemistry.

[9]  Xu,et al.  Standard electrochemical behavior of high-quality, boron-doped polycrystalline diamond thin-film electrodes , 2000, Analytical chemistry.

[10]  J. Kong,et al.  Probing trace phenols based on mediator-free alumina sol--gel-derived tyrosinase biosensor. , 2000, Analytical chemistry.

[11]  Akira Fujishima,et al.  Tyrosinase-modified boron-doped diamond electrodes for the determination of phenol derivatives , 2002 .

[12]  J M Pingarrón,et al.  Composite electrochemical biosensors: a comparison of three different electrode matrices for the construction of amperometric tyrosinase biosensors. , 2002, Biosensors & bioelectronics.

[13]  X. Qiu,et al.  Amperometric glucose sensor based on enzyme-modified boron-doped diamond electrode by cross-linking method , 2004 .

[14]  R. M. Wightman,et al.  Real-time characterization of dopamine overflow and uptake in the rat striatum , 1988, Neuroscience.

[15]  M. D'evelyn,et al.  Structure and energetics of clean and hydrogenated diamond (100) surfaces by molecular mechanics , 1992 .

[16]  A. Fujishima,et al.  Electrochemical Oxidation of NADH at Highly Boron-Doped Diamond Electrodes. , 1999, Analytical chemistry.

[17]  L. Tang,et al.  Biocompatibility of chemical-vapour-deposited diamond. , 1995, Biomaterials.

[18]  V. Sharma,et al.  Mushroom tyrosinase: recent prospects. , 2003, Journal of agricultural and food chemistry.

[19]  J. Wang,et al.  Amperometric biosensor for phenols based on a tyrosinase-graphite-epoxy biocomposite. , 1994, The Analyst.

[20]  Sahar Rashid-Nadimi,et al.  Voltammetric determination of ascorbic acid and dopamine in the same sample at the surface of a carbon paste electrode modified with polypyrrole/ferrocyanide films , 2005 .

[21]  Kim R. Rogers,et al.  Improved selective electrocatalytic oxidation of phenols by tyrosinase-based carbon paste electrode biosensor , 2000 .

[22]  S. Cosnier,et al.  A biosensor as warning device for the detection of cyanide, chlorophenols, atrazine and carbamate pesticides , 1995 .

[23]  Shannon Haymond,et al.  Direct electrochemistry of cytochrome C at nanocrystalline boron-doped diamond. , 2002, Journal of the American Chemical Society.

[24]  M. L. Mena,et al.  Development of a tyrosinase biosensor based on gold nanoparticles-modified glassy carbon electrodes: Application to the measurement of a bioelectrochemical polyphenols index in wines , 2005 .

[25]  S. Dzyadevych,et al.  Conductometric tyrosinase biosensor for the detection of diuron, atrazine and its main metabolites. , 2004, Talanta.

[26]  M. Grunze,et al.  An XPS study of the composition of thin polyimide films formed by vapor deposition , 1988 .

[27]  D. Tarbell,et al.  New Method to Prepare N-t-Butoxycarbonyl Derivatives and the Corresponding Sulfur Analogs from di-t-Butyl Dicarbonate or di-t-Butyl Dithiol Dicarbonates and Amino Acids. , 1972, Proceedings of the National Academy of Sciences of the United States of America.

[28]  Hiroshi Kawarada,et al.  Electrolyte-Solution-Gate FETs Using Diamond Surface for Biocompatible Ion Sensors , 2001 .

[29]  Silvia Fabiano,et al.  Amperometric tyrosinase based biosensor using an electrogenerated polythiophene film as an entrapment support. , 2003, Talanta.

[30]  C. Comninellis,et al.  Electrochemical Behavior of Synthetic Diamond Thin Film Electrodes , 1999 .

[31]  Songqin Liu,et al.  Renewable phenol biosensor based on a tyrosinase-colloidal gold modified carbon paste electrode , 2003 .

[32]  K. Hasebe,et al.  Differential pulse polarographic determination of some carcinogenic nitrosamines. , 1975, Analytical chemistry.

[33]  Keiichi Kaneto,et al.  Amperometric phenol biosensor based on covalent immobilization of tyrosinase onto an electrochemically prepared novel copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film , 2004 .

[34]  M. Slavik,et al.  Detection of Campylobacter jejuni in poultry samples using an enzyme-linked immunoassay coupled with an enzyme electrode. , 2001, Biosensors & bioelectronics.

[35]  Dermot Diamond,et al.  Development of a biosensor for endocrine disrupting compounds based on tyrosinase entrapped within a poly(thionine) film. , 2004, Biosensors & bioelectronics.

[36]  Su-Moon Park,et al.  Direct electrochemical assay of glucose using boron-doped diamond electrodes , 2005 .