Perfusion Linearity and Its Applications

Perfusion analysis computes blood flow parameters (blood volume, blood flow, mean transit time) from the observed flow of contrast agent, passing through the patient's vascular system. Perfusion deconvolution has been widely accepted as the principal numerical tool for perfusion analysis, and is used routinely in clinical applications. This extensive use of perfusion in clinical decision-making makes numerical stability and robustness of perfusion computations vital for accurate diagnostics and patient safety. The main goal of this paper is to propose a novel approach for validating numerical properties of perfusion algorithms. The approach is based on Perfusion Linearity Property (PLP), which we find in perfusion deconvolution, as well as in many other perfusion techniques. PLP allows one to study perfusion values as weighted averages of the original imaging data. This, in turn, uncovers hidden problems with the existing deconvolution techniques, and may be used to suggest more reliable computational approaches and methodology.

[1]  B. Rosen,et al.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis , 1996, Magnetic resonance in medicine.

[2]  Steve Halligan,et al.  Quantitative tumor perfusion assessment with multidetector CT: are measurements from two commercial software packages interchangeable? , 2007, Radiology.

[3]  Mario Bertero,et al.  The Stability of Inverse Problems , 1980 .

[4]  G N Stewart,et al.  Researches on the Circulation Time in Organs and on the Influences which affect it , 1893, The Journal of physiology.

[5]  L. Axel Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis. , 1980, Radiology.

[6]  K. Miles,et al.  CT derived Patlak images of the human kidney. , 1999, The British journal of radiology.

[7]  M. Lev,et al.  CT perfusion imaging of acute stroke: the need for arrival time, delay insensitive, and standardized postprocessing algorithms? , 2010, Radiology.

[8]  B. Rosen,et al.  Tracer arrival timing‐insensitive technique for estimating flow in MR perfusion‐weighted imaging using singular value decomposition with a block‐circulant deconvolution matrix , 2003, Magnetic resonance in medicine.

[9]  Per Christian Hansen,et al.  Deconvolution and Regularization with Toeplitz Matrices , 2002, Numerical Algorithms.

[10]  Ting-Yim Lee Functional CT: physiological models , 2002 .

[11]  C S Patlak,et al.  Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data , 1983, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[12]  Steven E. Rigdon,et al.  Model-Oriented Design of Experiments , 1997, Technometrics.

[13]  Signal analysis of impulse response functions in MR and CT measurements of cerebral blood flow. , 2005, Journal of theoretical biology.

[14]  Scott Fields,et al.  Mapping pathophysiological features of breast tumors by MRI at high spatial resolution , 1997, Nature Medicine.

[15]  T S Koh,et al.  A numerical method for estimating blood flow by dynamic functional imaging. , 2002, Medical engineering & physics.

[16]  F. Ståhlberg,et al.  Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques , 2000, Magnetic resonance in medicine.

[17]  Tong San Koh,et al.  Assessment of perfusion by dynamic contrast-enhanced imaging using a deconvolution approach based on regression and singular value decomposition , 2004, IEEE Transactions on Medical Imaging.

[18]  D. Gadian,et al.  Quantification of bolus‐tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularization , 2003, Magnetic resonance in medicine.

[19]  L. K. Hansen,et al.  Defining a local arterial input function for perfusion MRI using independent component analysis , 2004, Magnetic resonance in medicine.

[20]  Hamid Krim,et al.  An Independent Component Analysis Approach for Minimizing Effects of Recirculation in Dynamic Susceptibility Contrast Magnetic Resonance Imaging , 2007, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.