Continuous capacitance-voltage spectroscopy mapping for scanning microwave microscopy.

A new method, scanning sawtooth capacitance spectroscopy (SSCS), is proposed to measure a map of capacitance/voltage curves (C-V) by applying a low frequency voltage sawtooth signal (20-100 Hz) to the AFM tip while scanning. For this a scanning microwave microscope (SMM) is used to acquire calibrated capacitance data in the high frequency range of 1-20 GHz. While the capacitance is acquired pixel by pixel, the applied voltage signal is recorded as well, and each pixel of the capacitance is assigned the corresponding voltage value. Assuming the voltage variable is smooth over time, adjacent pixels within a scan line will have similar voltage values and a small sequence of neighboring pixels can be combined into a virtual C-V spectroscopy curve. With standard SMM operation parameters roughly 26,000 C-V curves can be acquired within few minutes data acquisition time. The method is demonstrated for n-type and p-type silicon semiconductor samples and can be applied to other samples including new materials and bio-membranes.

[1]  Jing-jiang Yu,et al.  Attofarad capacitance measurement corresponding to single-molecular level structural variations of self-assembled monolayers using scanning microwave microscopy , 2010 .

[2]  H. Grubin The physics of semiconductor devices , 1979, IEEE Journal of Quantum Electronics.

[3]  Christian Rankl,et al.  Calibrated nanoscale dopant profiling using a scanning microwave microscope , 2012 .

[4]  J. Marchiando,et al.  Scanning capacitance microscopy applied to two-dimensional dopant profiling of semiconductors , 1997 .

[5]  J. J. Yu,et al.  Advanced Characterization of Material Properties on the Nanometer Scale Using Atomic Force Microscopy , 2012 .

[6]  Clayton C. Williams,et al.  Quantitative measurement of two-dimensional dopant profile by cross-sectional scanning capacitance microscopy , 1997 .

[7]  Steven M. Anlage,et al.  Nanometer-scale material contrast imaging with a near-field microwave microscope , 2007 .

[8]  Trudo Clarysse,et al.  Status and review of two-dimensional carrier and dopant profiling using scanning probe microscopy , 2000 .

[9]  F. Kienberger,et al.  Nanoscale materials and device characterization via a scanning microwave microscope , 2009, 2009 IEEE International Conference on Microwaves, Communications, Antennas and Electronics Systems.

[10]  Trudo Clarysse,et al.  Epitaxial staircase structure for the calibration of electrical characterization techniques , 1998 .

[11]  T. M. Wallis,et al.  A near-field scanning microwave microscope for characterization of inhomogeneous photovoltaics. , 2012, The Review of scientific instruments.

[12]  D. W. van der Weide,et al.  Quantitative scanning near-field microwave microscopy for thin film dielectric constant measurement. , 2008, The Review of scientific instruments.

[13]  J. Niegemann,et al.  A calibration algorithm for nearfield scanning microwave microscopes , 2012, 2012 12th IEEE International Conference on Nanotechnology (IEEE-NANO).

[14]  Hemantha K. Wickramasinghe,et al.  Lateral dopant profiling with 200 nm resolution by scanning capacitance microscopy , 1989 .

[15]  Pavel Kabos,et al.  Frequency-selective contrast on variably doped p-type silicon with a scanning microwave microscope , 2012 .

[16]  T. M. Wallis,et al.  Calibrated nanoscale capacitance measurements using a scanning microwave microscope. , 2010, The Review of scientific instruments.

[17]  E. Bertagnolli,et al.  Quantitative scanning capacitance spectroscopy , 2003 .

[18]  E. Gornik,et al.  Mechanism of bias-dependent contrast in scanning-capacitance-microscopy images , 2001 .

[19]  F. Kienberger,et al.  Scanning microwave microscopy/spectroscopy on metal-oxide-semiconductor systems , 2010 .

[20]  R. Wiesendanger,et al.  The physical principles of scanning capacitance spectroscopy , 2001 .