Three‐Dimensional Anisotropy Contrast Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (3DAC PROPELLER) on a 3.0T System: A New Modality for Routine Clinical Neuroimaging

Background. Clinical magnetic resonance imaging (MRI) has recently entered the “high‐field” era, and systems equipped with 3.0–4.0T superconductive magnets are becoming the gold standard for diagnostic imaging. While higher signal‐to‐noise ratio (S/N) is a definite advantage of higher field systems, higher susceptibility effect remains to be a significant trade‐off. To take advantage of a higher field system in performing routine clinical images of higher anatomical resolution, we implemented a vector contrast image technique to 3.0T imaging, three‐dimensional anisotropy contrast (3DAC), with a PROPELLER (Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction) sequence, a method capable of effectively eliminating undesired artifacts on rapid diffusion imaging sequences. Methods. One hundred subjects (20 normal volunteers and 80 volunteers with various central nervous system diseases) participated in the study. Anisotropic diffusion‐weighted PROPELLER images were obtained on a General Electric (Waukesha, WI, USA) Signa 3.0T for each axis, with b‐value of 1100 sec/mm2. Subsequently, 3DAC images were constructed using in‐house software written on MATLAB (MathWorks, Natick, MA, USA). Results. The vector contrast allows for providing exquisite anatomical detail illustrated by clear identification of all major tracts through the entire brain. 3DAC images provide better anatomical resolution for brainstem glioma than higher‐resolution T2 reversed images. Degenerative processes of disease‐specific tracts were clearly identified as illustrated in cases of multiple system atrophy and Joseph–Machado disease. Conclusion. Anatomical images of significantly higher resolution than the best current standard, T2 reversed images, were successfully obtained. As a technique readily applicable under routine clinical setting, 3DAC PROPELLER on a 3.0T system will be a powerful addition to diagnostic imaging.

[1]  M S Buchsbaum,et al.  MRI white matter diffusion anisotropy and PET metabolic rate in schizophrenia , 1998, Neuroreport.

[2]  Hitoshi Matsuzawa,et al.  Isotropic component trace analysis. , 2005, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[3]  Yukihihj Fum High-resolution T2-reversed magnetic resonance imaging on a high magnetic field system , 1998 .

[4]  T Nakada,et al.  Magnetic resonance axonography of the rat spinal cord , 1994, Neuroreport.

[5]  Y. Fujii,et al.  Three-dimensional anisotropy contrast magnetic resonance axonography to predict the prognosis for motor function in patients suffering from stroke. , 2001, Journal of neurosurgery.

[6]  Robert T Knight,et al.  High-field, T2 reversed MRI of the hippocampus in transient global amnesia , 2005, Neurology.

[7]  L. M. MILNE-THOMSON,et al.  Vector and Tensor Analysis , 1949, Nature.

[8]  M. Raichle,et al.  Tracking neuronal fiber pathways in the living human brain. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[9]  Hitoshi Matsuzawa,et al.  Three-dimensional anisotropy contrast magnetic resonance imaging of the rat nervous system: MR axonography , 1995, Neuroscience Research.

[10]  J. Pekar,et al.  MR color mapping of myelin fiber orientation. , 1991, Journal of computer assisted tomography.

[11]  T. Vogl Clinical Application of Magnetic Resonance Angiography , 1992 .

[12]  Tsutomu Nakada,et al.  Clinical Experience on 3.0 T Systems in Niigata, 1996 to 2002 , 2003, Investigative radiology.

[13]  T Nakada,et al.  Clinical application of three-dimensional anisotropy contrast magnetic resonance axonography. Technical note. , 1999, Journal of neurosurgery.

[14]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[15]  T Nakada,et al.  High-resolution T2-reversed magnetic resonance imaging on a high magnetic field system. Technical note. , 1998, Journal of neurosurgery.

[16]  T. Nakada,et al.  Absolute eigenvalue diffusion tensor analysis for human brain maturation , 2003, NMR in biomedicine.

[17]  P. Basser,et al.  In vivo fiber tractography using DT‐MRI data , 2000, Magnetic resonance in medicine.

[18]  P. Basser,et al.  Estimation of the effective self-diffusion tensor from the NMR spin echo. , 1994, Journal of magnetic resonance. Series B.

[19]  High-field, high-resolution MR imaging of the human indusium griseum. , 1999, AJNR. American journal of neuroradiology.