Most design codes encourage the staggering of lapped splices in a section, such that a portion of the bars in the cross section remains continuous throughout the lap zone. A penalty on lap length may be imposed if all bars are lapped at one section. In the literature, however, almost all tested specimens have had all reinforcement lapped at the same section. This paper presents results of tests carried out to shed some new light on the behaviour of lap splices where only a portion of bars is lapped. To this end, four point bending tests were carried out on 24 full-scale beams with all or part of the longitudinal reinforcement lap spliced at mid-span. The beams were reinforced with either 16 or 20 mm diameter rebars, included two grades of concrete and various lap splices configurations, all confined by links. All the beams were designed with the same concrete cover and with the minimum amount of transverse reinforcement permitted by MC2010, equal to 50 % of the area of the lapped bars. The resistance and the residual strength of the splices were measured and compared with the results of specimens with continuous bars and with all bars lapped. The results show that lapping only a portion of bars at a section impairs splice strength, although some post-peak strength is maintained by the continuous bars. These outcomes raise questions over the validity of EC2 and ACI 318-11 provisions which allow a reduction in lap-length when splices are staggered.
[1]
Keith A. Jones,et al.
The splitting forces generated by bond
,
1995
.
[2]
Ralejs Tepfers,et al.
A theory of bond applied to overlapped tensile reinforcement splices for deformed bars
,
1973
.
[3]
Ezio Giuriani,et al.
Role of Stirrups and Residual Tensile Strength of Cracked Concrete on Bond
,
1991
.
[4]
Giovanni Plizzari,et al.
Transverse reinforcement effects on anchored deformed bars
,
1998
.
[5]
John Cairns.
Staggered lap joints for tension reinforcement
,
2014
.
[6]
Giovanni Plizzari,et al.
INFLUENCE OF THE RELATIVE RIB AREA ON BOND BEHAVIOUR
,
2014
.
[7]
Luc Taerwe,et al.
fib model code for concrete structures 2010
,
2013
.
[8]
Comite Euro-International du Beton,et al.
CEB-FIP Model Code 1990 : design code
,
1993
.
[9]
G. P. Rosati,et al.
BOND AND SPLITTING IN BAR PULL-OUT: BEHAVIOURAL LAWS AND CONCRETE COVER ROLE
,
1997
.
[10]
Jonas Magnusson,et al.
Bond and Anchorage of Ribbed Bars in High-Strength Concrete
,
2000
.
[11]
John Cairns.
Lap Splices of Bars in Bundles
,
2013
.
[12]
A W Beeby,et al.
CONCISE EUROCODE FOR THE DESIGN OF CONCRETE BUILDINGS. BASED ON BSI PUBLICATION DD ENV 1992-1-1: 1992. EUROCODE 2: DESIGN OF CONCRETE STRUCTURES. PART 1: GENERAL RULES AND RULES FOR BUILDINGS
,
1993
.