A method to correct hysteresis of scanning probe microscope images based on a sinusoidal model.

Piezoelectric actuators are widely used in scanning platforms of scanning probe microscopes (SPMs). However, the hysteresis of piezoelectric actuators reduces positioning accuracy and results in distorted SPM images. When regular raster scanning of SPM starts, the piezoelectric actuators move repeatedly at the same scanning range and frequency once the scanning parameters are set. In this study, a practical and simple mathematical model derived from experimental phenomenon, which is the combination of sinusoidal and linear functions, was proposed to describe the hysteresis behavior of piezoelectric actuators with repeated scanning. The model parameter was calculated from the coordinates of matched feature points in the trace and retrace images of ordinary sample obtained with an atomic force microscope (AFM). Experimental results show that the hysteresis of the scanned images is decreased from 107.46 pixels to 2.50 pixels after correction, with a width of 800 pixels. Hysteresis in other scanned images with different scanning frequencies and ranges was also corrected effectively using this model. The proposed model can be used to correct the hysteresis of AFM images without using any expensive displacement sensors or standard samples. The model is suitable and easy to be integrated into the scanning program of AFM without requiring hardware modifications.

[1]  C. Gerber,et al.  Surface Studies by Scanning Tunneling Microscopy , 1982 .

[2]  Gerber,et al.  Atomic Force Microscope , 2020, Definitions.

[3]  K. Conradsen,et al.  Hysteresis correction of scanning tunneling microscope images , 1994 .

[4]  David G. Lowe,et al.  Object recognition from local scale-invariant features , 1999, Proceedings of the Seventh IEEE International Conference on Computer Vision.

[5]  Santosh Devasia,et al.  A Survey of Control Issues in Nanopositioning , 2007, IEEE Transactions on Control Systems Technology.

[6]  Santosh Devasia,et al.  Feedback-Linearized Inverse Feedforward for Creep, Hysteresis, and Vibration Compensation in AFM Piezoactuators , 2007, IEEE Transactions on Control Systems Technology.

[7]  A. Fleming,et al.  Evaluation of charge drives for scanning probe microscope positioning stages , 2008, 2008 American Control Conference.

[8]  Wei Chu,et al.  A moving window correlation method to reduce the distortion of scanning probe microscope images. , 2009, The Review of scientific instruments.

[9]  Qingze Zou,et al.  A review of feedforward control approaches in nanopositioning for high-speed spm , 2009 .

[10]  Yangmin Li,et al.  Modeling and High Dynamic Compensating the Rate-Dependent Hysteresis of Piezoelectric Actuators via a Novel Modified Inverse Preisach Model , 2013, IEEE Transactions on Control Systems Technology.

[11]  Jie Zhang,et al.  Mirror control with strain feedback and charge drive for high-performance of scanning probe microscope positioners , 2014 .

[12]  M. S. Rana,et al.  Creep, hysteresis, and vibration effects attenuation in an AFM PTS , 2014, 2014 European Control Conference (ECC).

[13]  Bo Song,et al.  High precision positioning control for SPM based nanomanipulation: A robust adaptive model reference control approach , 2014, 2014 IEEE/ASME International Conference on Advanced Intelligent Mechatronics.

[14]  Chun-Yi Su,et al.  Integral resonant damping for high-bandwidth control of piezoceramic stack actuators with asymmetric hysteresis nonlinearity , 2014 .

[15]  Li-Min Zhu,et al.  Modeling and Compensation of Asymmetric Hysteresis Nonlinearity for Piezoceramic Actuators With a Modified Prandtl–Ishlinskii Model , 2014, IEEE Transactions on Industrial Electronics.

[16]  Lei Zhou,et al.  Improving Atomic Force Microscopy Imaging by a Direct Inverse Asymmetric PI Hysteresis Model , 2015, Sensors.

[17]  Ian R. Petersen,et al.  Effect of Improved Tracking for Atomic Force Microscope on Piezo Nonlinear Behavior , 2015 .

[18]  Zhili Long,et al.  Hysteresis compensation of the Prandtl-Ishlinskii model for piezoelectric actuators using modified particle swarm optimization with chaotic map. , 2017, The Review of scientific instruments.

[19]  L. A. Bumm,et al.  Real-space post-processing correction of thermal drift and piezoelectric actuator nonlinearities in scanning tunneling microscope images. , 2016, The Review of scientific instruments.

[20]  Ulrich Gabbert,et al.  Inverse Compensation of Hysteresis Using Krasnoselskii-Pokrovskii Model , 2018, IEEE/ASME Transactions on Mechatronics.

[21]  Yongchun Fang,et al.  A high-efficiency Kalman filtering imaging mode for an atomic force microscopy with hysteresis modeling and compensation , 2018 .

[22]  Yanyan Wang,et al.  A new precise positioning method for piezoelectric scanner of AFM. , 2019, Ultramicroscopy.