Fast limited flip angle mr subtraction angiography

A fast MR angiography method is introduced that is capable of generating difference images of blood vessels in scan times of 10–20 s. This is an order of magnitude faster than many previous methods. The fundamental concept ofthis approach is to use cardiac gating and acquire several phase encodings at least twice during each cardiac cycle using limited flip angles (LFAs) and repetition times in the 20 to 50 ms range. The encodings acquired during diastole are subtracted from those acquired during systole to generate the difference image. The contrast in the difference image is due both to the influx of unsaturated spins and to the loss of phase coherence of systolic blood moving at high velocity along a magnetic gradient. The systolic peak of the cardiac cycle is determined during reconstruction by shifting the systolic and diastolic “windows” until the difference signal is maximized. Ghost artifacts due to pulsatile flow are eliminated by a phase reordering technique similar in concept to those developed for suppression of breathing artifacts. Arteries in thick slices are successfully imaged and initial in vivo results are presented. © 1988 Academic Press, Inc.

[1]  M. Gado,et al.  Projection angiograms of blood labeled by adiabatic fast passage , 1986, Magnetic resonance in medicine.

[2]  L Axel,et al.  Respiratory effects in two-dimensional Fourier transform MR imaging. , 1986, Radiology.

[3]  J. Pauly,et al.  MR angiography by selective inversion recovery , 1987, Magnetic resonance in medicine.

[4]  L Axel,et al.  MR flow imaging by velocity-compensated/uncompensated difference images. , 1987, Journal of computer assisted tomography.

[5]  E M Haacke,et al.  Reducing motion artifacts in two-dimensional Fourier transform imaging. , 1986, Magnetic resonance imaging.

[6]  G T Gullberg,et al.  MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections. , 1987, Radiology.

[7]  A. Haase,et al.  Rapid NMR imaging of dynamic processes using the FLASII technique , 1986, Magnetic resonance in medicine.

[8]  J. Beltrán,et al.  Rheumatoid arthritis: MR imaging manifestations. , 1987, Radiology.

[9]  C. Dumoulin,et al.  Magnetic resonance angiography. , 1986, Radiology.

[10]  Albert Macovski,et al.  Magnetic Resonance Angiography , 1986, IEEE Transactions on Medical Imaging.

[11]  L Axel,et al.  Blood flow effects in magnetic resonance imaging. , 1984, Magnetic resonance annual.

[12]  R J Herfkens,et al.  Two-second MR images: comparison with spin-echo images in 29 patients. , 1987, AJR. American journal of roentgenology.

[13]  Richard Lorne Ehman,et al.  Spatial presaturation: a method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging. , 1987 .

[14]  D N Firmin,et al.  Blood flow imaging by cine magnetic resonance. , 1986, Journal of computer assisted tomography.

[15]  P. R. Moran,et al.  Artifacts from pulsatile flow in MR imaging. , 1986, Journal of computer assisted tomography.

[16]  V. Wedeen,et al.  Projective MRI angiography and quantitative flow‐volume densitometry , 1986, Magnetic resonance in medicine.

[17]  C L Dumoulin,et al.  Rapid scan magnetic resonance angiography , 1987, Magnetic resonance in medicine.

[18]  A. G. Collins,et al.  Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. , 1985, Journal of computer assisted tomography.

[19]  R. Meuli,et al.  Projective imaging of pulsatile flow with magnetic resonance. , 1985, Science.