In-line phase-contrast breast tomosynthesis: a phantom feasibility study at a synchrotron radiation facility

The major objective is to adopt, apply and test developed in-house algorithms for volumetric breast reconstructions from projection images, obtained in in-line phase-contrast mode. Four angular sets, each consisting of 17 projection images obtained from four physical phantoms, were acquired at beamline ID17, European Synchroton Radiation Facility, Grenoble, France. The tomosynthesis arc was  ±32°. The physical phantoms differed in complexity of texture and introduced features of interest. Three of the used phantoms were in-house developed, and made of epoxy resin, polymethyl-methacrylate and paraffin wax, while the fourth phantom was the CIRS BR3D. The projection images had a pixel size of 47 µm  ×  47 µm. Tomosynthesis images were reconstructed with standard shift-and-add (SAA) and filtered backprojection (FBP) algorithms. It was found that the edge enhancement observed in planar x-ray images is preserved in tomosynthesis images from both phantoms with homogeneous and highly heterogeneous backgrounds. In case of BR3D, it was found that features not visible in the planar case were well outlined in the tomosynthesis slices. In addition, the edge enhancement index calculated for features of interest was found to be much higher in tomosynthesis images reconstructed with FBP than in planar images and tomosynthesis images reconstructed with SAA. The comparison between images reconstructed by the two reconstruction algorithms shows an advantage for the FBP method in terms of better edge enhancement. Phase-contrast breast tomosynthesis realized in in-line mode benefits the detection of suspicious areas in mammography images by adding the edge enhancement effect to the reconstructed slices.

[1]  Guang-Hong Chen,et al.  Grating-based phase contrast tomosynthesis imaging: proof-of-concept experimental studies. , 2013, Medical physics.

[2]  Emilio Quaia,et al.  Mammography with synchrotron radiation: first clinical experience with phase-detection technique. , 2011, Radiology.

[3]  Taly Gilat Schmidt,et al.  Medical Imaging 2018: Physics of Medical Imaging , 2018 .

[4]  Niko Papanikolaou,et al.  The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis , 2009, Journal of applied clinical medical physics.

[5]  Andreas Fehringer,et al.  Statistical iterative reconstruction algorithm for X-ray phase-contrast CT , 2015, Scientific Reports.

[6]  Madhavi Raghu,et al.  Early clinical experience with digital breast tomosynthesis for screening mammography. , 2015, Radiology.

[7]  Franz Pfeiffer,et al.  X-ray phase-contrast tomosynthesis for improved breast tissue discrimination. , 2014, European journal of radiology.

[8]  Emily F Conant,et al.  Breast cancer screening with tomosynthesis and digital mammography-reply. , 2014, JAMA.

[9]  Yiheng Zhang,et al.  High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array. , 2012, Medical physics.

[10]  E Castelli,et al.  The mammography project at the SYRMEP beamline. , 2008, European journal of radiology.

[11]  G Panayiotakis,et al.  A multiple projection method for digital tomosynthesis. , 1992, Medical physics.

[12]  E Castelli,et al.  Mammography with synchrotron radiation: phase-detection techniques. , 2000, Radiology.

[13]  David R Pickens,et al.  Characterization of the phase-contrast radiography edge-enhancement effect in a cabinet x-ray system. , 2006, Physics in medicine and biology.

[14]  Giovanni Mettivier,et al.  Dedicated breast computed tomography: Basic aspects. , 2015, Medical physics.

[15]  Peter Cloetens,et al.  Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography , 2010, Physics in medicine and biology.

[16]  A Bravin,et al.  A numerical wave-optical approach for the simulation of analyzer-based x-ray imaging. , 2007, Optics express.

[17]  K Bliznakova,et al.  Evaluation of digital breast tomosynthesis reconstruction algorithms using synchrotron radiation in standard geometry. , 2010, Medical physics.

[18]  David R Pickens,et al.  Phase-contrast digital tomosynthesis. , 2011, Medical physics.

[19]  Alessandro Olivo,et al.  Proof-of-concept demonstration of edge-illumination x-ray phase contrast imaging combined with tomosynthesis , 2014, Physics in medicine and biology.

[20]  Ivan Buliev,et al.  A platform for Image Reconstruction in X-ray Imaging - Medical Applications using CBCT and DTS algorithms , 2014, Comput. Sci. J. Moldova.

[21]  I. Sechopoulos A review of breast tomosynthesis. Part I. The image acquisition process. , 2013, Medical physics.

[22]  Franz Pfeiffer,et al.  Penalized maximum likelihood reconstruction for x-ray differential phase-contrast tomography. , 2015, Medical physics.

[23]  Daniel B Kopans,et al.  Digital breast tomosynthesis from concept to clinical care. , 2014, AJR. American journal of roentgenology.

[24]  Ge Wang,et al.  Fourier transform-based iterative method for differential phase-contrast computed tomography. , 2012, Optics letters.

[25]  Kristina Bliznakova,et al.  Contrast Detail Phantoms for X-ray Phase-Contrast Mammography and Tomography , 2016, Digital Mammography / IWDM.

[26]  Kristina Bliznakova,et al.  A software platform for phase contrast x-ray breast imaging research , 2015, Comput. Biol. Medicine.

[27]  Emilio Quaia,et al.  Clinical mammography at the SYRMEP beam line , 2007 .

[28]  Mark A. Anastasio,et al.  Depth resolution properties of in-line X-ray phase-contrast tomosynthesis , 2014, Medical Imaging.

[29]  Franz Pfeiffer,et al.  3D Algebraic Iterative Reconstruction for Cone-Beam X-Ray Differential Phase-Contrast Computed Tomography , 2015, PloS one.

[30]  Timur E. Gureyev,et al.  Investigation of the imaging quality of synchrotron-based phase-contrast mammographic tomography , 2014 .

[31]  E. Vallazza,et al.  Clinical mammography at the SYRMEP beam line : Toward the digital detection system , 2007 .

[32]  Marcus J Kitchen,et al.  A feasibility study of X-ray phase-contrast mammographic tomography at the Imaging and Medical beamline of the Australian Synchrotron. , 2015, Journal of synchrotron radiation.