Quantification of lesion size, depth, and uptake using a dual-head molecular breast imaging system.

A method to perform quantitative lesion analysis in molecular breast imaging (MBI) was developed using the opposing views from a novel dual-head dedicated gamma camera. Monte Carlo simulations and phantom models were used to simulate MBI images with known lesion parameters. A relationship between the full widths at 25%, 35%, and 50% of the maximum of intensity profiles through lesions and the true lesion diameter as a function of compressed breast thickness was developed in order to measure lesion diameter. Using knowledge of compressed breast thickness and the attenuation of gamma rays in soft tissue, a method was developed to measure the depth of the lesion to the collimator face. Using the measured lesion diameter and measurements of counts in the lesion and background breast region, relative radiotracer uptake or tumor to background ratio (T/B ratio) was calculated. Validation of the methods showed that the size, depth, and T/B ratio can be accurately measured for a range of small breast lesions with T/B ratios between 10:1 and 40:1 in breasts with compressed thicknesses between 4 and 10 cm. Future applications of this work include providing information about lesion location in patients for performing a biopsy of site and the development of a threshold for the T/B ratio that can distinguish benign from malignant disease.

[1]  M. Souvatzoglou,et al.  Uptake and washout of 99mTcV-dimercaptosuccinic acid and 99mTc-sestamibi in the assessment of histological type and grade in breast cancer , 2002, Nuclear medicine communications.

[2]  Martin P. Tornai,et al.  High resolution CsI(Tl)/Si-PIN detector development for breast imaging , 1998 .

[3]  Viviane,et al.  Technetium-99m-sestamibi uptake in breast tumor and associated lymph nodes. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  J. Buscombe,et al.  Correlation between uptake of Tc-99m sestaMIBI and prognostic factors of breast cancer. , 1999, Anticancer research.

[5]  R. Orda,et al.  99Tcm-tetrofosmin scintimammography for detecting breast cancer: a comparative study with 99Tcm-MIBI , 2001 .

[6]  Francesco Scopinaro,et al.  Multi-PSPMT scintillating camera , 1997 .

[7]  I. Blevis,et al.  Evaluation of a small cadmium zinc telluride detector for scintimammography. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  E. Hoffman,et al.  Evaluation of breast tumor detectability with two dedicated, compact scintillation cameras , 2002 .

[9]  M. O’Connor,et al.  Comparison of small field of view gamma camera systems for scintimammography , 2005, Nuclear medicine communications.

[10]  M. O’Connor,et al.  Effect of Collimator Selection on Tumor Detection for Dedicated Nuclear Breast Imaging Systems , 2006, IEEE Transactions on Nuclear Science.

[11]  M. O’Connor,et al.  A Monte Carlo Model for Energy Spectra Analysis in Dedicated Nuclear Breast Imaging , 2008, IEEE Transactions on Nuclear Science.

[12]  J. Kim,et al.  Development of a miniature scintillation camera using an NaI(Tl) scintillator and PSPMT for scintimammography. , 2000, Physics in medicine and biology.

[13]  Gina Caravaglia,et al.  Scintimammography with dedicated breast camera detects and localizes occult carcinoma. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  Carrie B. Hruska,et al.  Molecular Breast Imaging: Advantages and Limitations of a Scintimammographic Technique in Patients with Small Breast Tumors , 2007, The breast journal.

[15]  J. Maublant,et al.  Does 99mTc-Sestamibi Uptake Discriminate Breast Tumors? , 2004, Cancer investigation.

[16]  B. Welch,et al.  X-ray stereotactic lesion localization in conjunction with dedicated scintimammography , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[17]  W. Moses,et al.  A discrete scintillation camera module using silicon photodiode readout of CsI(TI) crystals for breast cancer imaging , 1998 .

[18]  Small field of view scintimammography gamma camera integrated to a stereotactic core biopsy digital X-ray system , 2002 .

[19]  I. Khalkhali,et al.  Design and assessment of a scintigraphy‐guided biplane localization technique for breast tumours: A phantom study , 1996, Nuclear medicine communications.

[20]  I. Khalkhali,et al.  Radionuclide-guided stereotactic prebiopsy localization of nonpalpable breast lesions with normal mammograms. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  B. Welch,et al.  Optimization of dedicated scintimammography procedure using detector prototypes and compressible phantoms , 2000 .