Hybrid Spectral Micro-CT: System Design, Implementation, and Preliminary Results

Spectral CT has proven an important development in biomedical imaging, and there have been several publications in the past years demonstrating its merits in pre-clinical and clinical applications. In 2012, Xu reported that near-term implementation of spectral micro-CT could be enhanced by a hybrid architecture: a narrow-beam spectral “interior” imaging chain integrated with a traditional wide-beam “global” imaging chain. This hybrid integration coupled with compressive sensing (CS)-based interior tomography demonstrated promising results for improved contrast resolution, and decreased system cost and radiation dose. The motivation for the current study is implementation and evaluation of the hybrid architecture with a first-of-its-kind hybrid spectral micro-CT system. Preliminary results confirm improvements in both contrast and spatial resolution. This technology is shown to merit further investigation and potential application in future spectral CT scanner design.

[1]  Wenxiang Cong,et al.  Optimization of K-edge imaging with spectral CT. , 2012, Medical physics.

[2]  Ewald Roessl,et al.  Abstract 2798: Fibrin-specific Spectral CT Molecular imaging Detects Ruptured Plaque without Calcium Interference , 2008 .

[3]  Willi A Kalender,et al.  Intensity distribution and impact of scatter for dual-source CT , 2007, Physics in medicine and biology.

[4]  Axel Thran,et al.  Atherosclerotic Plaque Composition : Analysis with Multicolor CT and Targeted Gold Nanoparticles 1 , 2010 .

[5]  Hakan Erdogan,et al.  Monotonic algorithms for transmission tomography , 2002, 5th IEEE EMBS International Summer School on Biomedical Imaging, 2002..

[6]  Rafidah Zainon,et al.  Toward quantifying the composition of soft tissues by spectral CT with Medipix3. , 2012, Medical physics.

[7]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[8]  S. Molloi,et al.  Segmentation and quantification of materials with energy discriminating computed tomography: a phantom study. , 2010, Medical physics.

[9]  Hengyong Yu,et al.  A soft-threshold filtering approach for reconstruction from a limited number of projections , 2010, Physics in medicine and biology.

[10]  A. Butler,et al.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE , 2010, European Radiology.

[11]  Hengyong Yu,et al.  Compressed sensing based interior tomography , 2009, Physics in medicine and biology.

[12]  J. Schlomka,et al.  Multienergy photon-counting K-edge imaging: potential for improved luminal depiction in vascular imaging. , 2008, Radiology.

[13]  R. Swennen,et al.  Principal components analysis of multienergy X-ray computed tomography of mineral samples , 2000 .

[14]  Anthony P. H. Butler,et al.  Image Reconstruction for Hybrid True-Color Micro-CT , 2012, IEEE Transactions on Biomedical Engineering.

[15]  S. Wildermuth,et al.  Dual- and multi-energy CT: approach to functional imaging , 2011, Insights into imaging.

[16]  Sabee Molloi,et al.  Spectral CT imaging of vulnerable plaque with two independent biomarkers , 2012, Physics in medicine and biology.

[17]  Katsuyuki Taguchi,et al.  Enabling photon counting clinical X-ray CT , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[18]  Tim B. F. Woodfield,et al.  NOVEL IMAGING METHODS FOR DETECTING CARTILAGE TISSUE QUALITY VIA MARS-MICRO COMPUTED TOMOGRAPHY , 2012 .

[19]  R. Doesburg,et al.  Spectral CT of carotid atherosclerotic plaque: comparison with histology , 2012, European Radiology.

[20]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .

[21]  S M Bentzen,et al.  Evaluation of the spatial resolution of a CT scanner by direct analysis of the edge response function. , 1983, Medical physics.

[22]  E. Roessl,et al.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors , 2007, Physics in medicine and biology.

[23]  P. Shikhaliev,et al.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application , 2011, Physics in medicine and biology.

[24]  Xuanqin Mou,et al.  Statistical Interior Tomography , 2010, IEEE Transactions on Medical Imaging.

[25]  Taly Gilat Schmidt,et al.  Region-of-interest material decomposition from truncated energy-resolved CT. , 2011, Medical physics.