Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring.

This article presents the fabrication and characterization of novel tattoo-based solid-contact ion-selective electrodes (ISEs) for non-invasive potentiometric monitoring of epidermal pH levels. The new fabrication approach combines commercially available temporary transfer tattoo paper with conventional screen printing and solid-contact polymer ISE methodologies. The resulting tattoo-based potentiometric sensors exhibit rapid and sensitive response to a wide range of pH changes with no carry-over effects. Furthermore, the tattoo ISE sensors endure repetitive mechanical deformation, which is a key requirement of wearable and epidermal sensors. The flexible and conformal nature of the tattoo sensors enable them to be mounted on nearly any exposed skin surface for real-time pH monitoring of the human perspiration, as illustrated from the response during a strenuous physical activity. The resulting tattoo-based ISE sensors offer considerable promise as wearable potentiometric sensors suitable for diverse applications.

[1]  Joshua Ray Windmiller,et al.  Stamp transfer electrodes for electrochemical sensing on non-planar and oversized surfaces. , 2012, The Analyst.

[2]  Richard P. Buck,et al.  Peer Reviewed: Tracing the History of Selective Ion Sensors , 2001 .

[3]  J. Bobacka Conducting Polymer‐Based Solid‐State Ion‐Selective Electrodes , 2006 .

[4]  Dermot Diamond,et al.  A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration , 2010 .

[5]  A. Monkman,et al.  Electrical conductivity enhancement of predoped polyaniline by stretch orientation , 1996 .

[6]  S. Galloway,et al.  Variations in Regional Sweat Composition in Normal Human Males , 2000, Experimental physiology.

[7]  Jaroslav Stejskal,et al.  Biocompatibility of polyaniline , 2012 .

[8]  K. Campbell,et al.  A comparative review of cutaneous pH. , 2002, Veterinary dermatology.

[9]  Joseph Wang,et al.  Wearable Electrochemical Sensors and Biosensors: A Review , 2013 .

[10]  Alexandra G Martinez,et al.  Electrochemical sensing based on printable temporary transfer tattoos. , 2012, Chemical communications.

[11]  Dermot Diamond,et al.  Real-time sweat pH monitoring based on a wearable chemical barcode micro-fluidic platform incorporating ionic liquids , 2012 .

[12]  Joseph Wang,et al.  Solid-state pH nanoelectrode based on polyaniline thin film electrodeposited onto ion-beam etched carbon fiber , 2002 .

[13]  J. Riu,et al.  Potentiometric strip cell based on carbon nanotubes as transducer layer: toward low-cost decentralized measurements. , 2011, Analytical chemistry.

[14]  W. Latzka,et al.  Water and electrolyte requirements for exercise. , 1999, Clinics in sports medicine.

[15]  D. Kaiser,et al.  Hydrogen ion and electrolyte excretion of the single human sweat gland , 1974, Pflügers Archiv.

[16]  A. Michalska,et al.  All-plastic, disposable, low detection limit ion-selective electrodes , 2004 .

[17]  K. Chung,et al.  Hydrogen ion-selective membrane electrodes based on alkyldibenzylamines as neutral carriers. , 1998, Talanta: The International Journal of Pure and Applied Analytical Chemistry.

[18]  Zhiyuan Luo,et al.  All-solid-state blood calcium sensors based on screen-printed poly(3,4-ethylenedioxythiophene) as the solid contact , 2012 .

[19]  F. Rius,et al.  Paper-based ion-selective potentiometric sensors. , 2012, Analytical chemistry.

[20]  Robert Koncki,et al.  Screen-printed reference electrodes for potentiometric measurements , 2004 .

[21]  R. Koncki,et al.  Strip thick-film silver ion-selective electrodes , 2003 .

[22]  R. Durst Ion‐Selective Electrodes – The Early Years , 2012 .

[23]  J Wang,et al.  Processible polyaniline as an advanced potentiometric pH transducer. Application to biosensors. , 1999, Analytical chemistry.