In vivo ultrasound electrode displacement strain imaging

The incidence of primary and secondary liver tumors has increased significantly over the last two decades. Due to poor liver function and/or distribution of lesions, surgery is often not an option for affected patients. An alternative to surgical resection, percutaneous radiofrequency ablation is often used to thermally destroy the tumor in situ. Radiofrequency ablation is evolving into one of the more popular minimally-invasive treatments for hepatic tumors. Monitoring the treated region is an important factor in the success of radiofrequency ablation, and ultrasound elastography could become a convenient, cost-effective means to delineate the thermal lesion boundaries for clinical personnel during the procedure. This study assesses “electrode displacement” strain imaging for monitoring abdominal radiofrequency ablation procedures. We present results utilizing a novel approach of displacing the ablation electrode itself to introduce the mechanical stimuli required for strain imaging. Utilizing a Siemens Antares clinical ultrasound scanner equipped with a research interface, ultrasound radiofrequency data were acquired immediately following radiofrequency ablation of porcine liver. The porcine liver was excised following the procedure, and the dimensions of the thermal lesion in the imaging plane measured by slicing though the lesion. Strain images of the lesions were produced offline using axial guidance based block-matching and multi-level motion tracking algorithms. The area of the lesion on the strain image was compared to the area of the lesion in pathology images obtained from eight separate lesions. The estimated linear correlation coefficient between the pathology image and the strain image was r = 0.961 (p ≪ .001) for manual segmentation using 4 observers. The area of the lesion in the strain image slightly underestimates the area of the lesion in the pathology image for all slices, agreeing with earlier ex-vivo experiments.

[1]  Tomy Varghese,et al.  Radio-frequency ablation electrode displacement elastography: a phantom study. , 2008, Medical physics.

[2]  Jingfeng Jiang,et al.  Finite element analysis of tissue deformation with a radiofrequency ablation electrode for strain imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Christopher L Brace,et al.  Microwave ablation with a single small-gauge triaxial antenna: in vivo porcine liver model. , 2007, Radiology.

[4]  T. Varghese,et al.  Two-dimensional multi-level strain estimation for discontinuous tissue , 2007, Physics in medicine and biology.

[5]  T. Varghese,et al.  Elastographic measurement of the area and volume of thermal lesions resulting from radiofrequency ablation: pathologic correlation. , 2003, AJR. American journal of roentgenology.

[6]  T. Varghese,et al.  Elastographic imaging of thermal lesions in the liver in vivo following radiofrequency ablation: preliminary results. , 2002, Ultrasound in medicine & biology.

[7]  Yanning Zhu,et al.  A Modified Block Matching Method for Real-Time Freehand Strain Imaging , 2002, Ultrasonic imaging.

[8]  Wen-zhi Chen,et al.  Pathological changes in human malignant carcinoma treated with high-intensity focused ultrasound. , 2001, Ultrasound in medicine & biology.

[9]  Luigi Solbiati,et al.  Radiofrequency thermal ablation of hepatic metastases. , 2001, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[10]  T. Krouskop,et al.  Elastographic characterization of HIFU-induced lesions in canine livers. , 1999, Ultrasound in medicine & biology.

[11]  L Solbiati,et al.  Hepatic metastases: percutaneous radio-frequency ablation with cooled-tip electrodes. , 1997, Radiology.

[12]  Percutaneous Us-Guided Radio-Frequency Tissue Ablation of Liver Metastases: Treatment and Follow-Up in 16 Patients , 1997 .