Effect of pelvic tilt and rotation on cup orientation in standing anteroposterior radiographs

Background: Individual pelvic tilt and rotation have wide variability that can affect the measurement of cup orientation in anteroposterior (AP) radiographs. The purpose of this study was to analyse the effect of pelvic tilt and rotation on radiographic measurements of cup orientation. Methods: A total of 53 patients (63 hips) were included in this study. The patients underwent a computed tomography study with standing AP pelvis radiographs taken both preoperatively and approximately 3 months postoperatively. We used 2-dimensional/3-dimensional matching to measure the pelvic tilt and rotation, and the non-standardised and standardised cup orientation. Results: There was no difference in the pelvic tilt and rotation between the preoperative and postoperative radiographs. The distribution of the differences between the non-standardised and standardised cup anteversion exhibited a change within 5° in only 34/63 (54%) hips. The pelvic tilt correlated with the difference between the non-standardised and standardised cup anteversion, but the pelvic rotation did not. When all 63 hips were separated into the right and left sides, the pelvic rotation inversely correlated with the pelvic tilt-adjusted difference between the non-standardised and standardised cup anteversion of the right side but directly correlated with that of the left side. Conclusions: The current study demonstrated that the measurement of cup anteversion in standing AP radiographs is significantly affected by both the pelvic tilt and pelvic rotation. An improved understanding of the pelvic orientation may eventually allow for desired cup positioning on a patient-specific basis to potentially reduce complications associated with the malposition of the cup.

[1]  A. Cotten,et al.  Variations of pelvic anteversion in the lying and standing positions analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup , 2001, Surgical and Radiologic Anatomy.

[2]  Hilla Peretz,et al.  Ju n 20 03 Schrödinger ’ s Cat : The rules of engagement , 2003 .

[3]  B Blondel,et al.  Pelvic tilt measurement before and after total hip arthroplasty. , 2009, Orthopaedics & traumatology, surgery & research : OTSR.

[4]  Karl-Heinz Widmer,et al.  A simplified method to determine acetabular cup anteversion from plain radiographs. , 2004, The Journal of arthroplasty.

[5]  L. G. Watson,et al.  Radiographic calculation of anteversion in acetabular prostheses. , 1995, The Journal of arthroplasty.

[6]  D. Murray The definition and measurement of acetabular orientation. , 1993, The Journal of bone and joint surgery. British volume.

[7]  M Tannast,et al.  Tilt and Rotation Correction of Acetabular Version on Pelvic Radiographs , 2005, Clinical orthopaedics and related research.

[8]  Stephen Lyman,et al.  CT Outperforms Radiography for Determination of Acetabular Cup Version after THA , 2009, Clinical orthopaedics and related research.

[9]  K. Widmer,et al.  Containment versus impingement: finding a compromise for cup placement in total hip arthroplasty , 2007, International Orthopaedics.

[10]  H. Tsuchiya,et al.  The influence of surgical approach on postoperative pelvic tilt after total hip arthroplasty , 2017, European Journal of Orthopaedic Surgery & Traumatology.

[11]  H. Uhthoff,et al.  Anteversion of the acetabular cup. Measurement of angle after total hip replacement. , 1986, The Journal of bone and joint surgery. British volume.

[12]  H. Gill,et al.  The relationship between operative and radiographic acetabular component orientation: which factors influence resultant cup orientation? , 2014, The bone & joint journal.

[13]  Hideki Yoshikawa,et al.  Measurements of Pelvic Flexion Angle Using Three-Dimensional Computed Tomography , 2003, Clinical orthopaedics and related research.

[14]  J. Pierrepont,et al.  Variation in functional pelvic tilt in patients undergoing total hip arthroplasty , 2017, The bone & joint journal.

[15]  Branislav Jaramaz,et al.  Functional Pelvic Orientation Measured from Lateral Standing and Sitting Radiographs , 2006, Clinical orthopaedics and related research.

[16]  A. Rosenberg,et al.  Preventing Leg Length Discrepancy and Instability After Total Hip Arthroplasty. , 2016, Instructional course lectures.

[17]  B. Jaramaz,et al.  A validation model for measurement of acetabular component position. , 2010, The Journal of arthroplasty.

[18]  Y. Okanoue,et al.  Chronological Changes in Functional Cup Position at 10 Years after Total Hip Arthroplasty , 2017, Hip international : the journal of clinical and experimental research on hip pathology and therapy.

[19]  Jens Kowal,et al.  Validation of a new method for determination of cup orientation in THA , 2009, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[20]  G. Zheng,et al.  Pelvic Tilt Is Minimally Changed by Total Hip Arthroplasty , 2013, Clinical orthopaedics and related research.

[21]  Kevin Ong,et al.  The epidemiology of revision total hip arthroplasty in the United States. , 2009, The Journal of bone and joint surgery. American volume.

[22]  M. Weaver,et al.  Does Fluoroscopy Improve Acetabular Component Placement in Total Hip Arthroplasty? , 2014, Clinical orthopaedics and related research.

[23]  B. Jolles,et al.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. , 2002, The Journal of arthroplasty.

[24]  Nobuhiko Sugano,et al.  Does Pelvic Sagittal Inclination in the Supine and Standing Positions Change Over 10 Years of Follow-Up After Total Hip Arthroplasty? , 2017, The Journal of arthroplasty.

[25]  Matthias Wiese,et al.  Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography , 2006, Archives of Orthopaedic and Trauma Surgery.

[26]  K. Kaufman,et al.  The 2008 Frank Stinchfield Award: Variation in Postoperative Pelvic Tilt May Confound the Accuracy of Hip Navigation Systems , 2009, Clinical orthopaedics and related research.

[27]  K. Soffe,et al.  Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. , 1998, The Journal of arthroplasty.

[28]  Guoyan Zheng,et al.  HipMatch: An object-oriented cross-platform program for accurate determination of cup orientation using 2D-3D registration of single standard X-ray radiograph and a CT volume , 2009, Comput. Methods Programs Biomed..

[29]  B. Jaramaz,et al.  Imaging and Navigation Measurement of Acetabular Component Position in THA , 2009, Clinical orthopaedics and related research.

[30]  L. Dorr,et al.  Quantification of Pelvic Tilt in Total Hip Arthroplasty , 2010, Clinical orthopaedics and related research.

[31]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[32]  F. Layher,et al.  The rationale for tilt-adjusted acetabular cup navigation. , 2008, The Journal of bone and joint surgery. American volume.

[33]  D. McCollum,et al.  Dislocation after total hip arthroplasty. Causes and prevention. , 1990, Clinical orthopaedics and related research.

[34]  T. Renkawitz,et al.  Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography , 2017, International Orthopaedics.

[35]  T. Kobayashi,et al.  An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs. , 2014, The bone & joint journal.

[36]  Tomoyuki Saito,et al.  Preoperative planning for implant placement with consideration of pelvic tilt in total hip arthroplasty: postoperative efficacy evaluation , 2016, BMC Musculoskeletal Disorders.

[37]  Burkhard Lembeck,et al.  Pelvic tilt makes acetabular cup navigation inaccurate , 2005, Acta orthopaedica.

[38]  M. Tannast,et al.  Femoroacetabular impingement: radiographic diagnosis--what the radiologist should know. , 2007, AJR. American journal of roentgenology.

[39]  Y-K Lee,et al.  Reliability and validity of measuring version of the acetabular component. , 2012, The Journal of bone and joint surgery. British volume.

[40]  Frank Langlotz,et al.  Anatomic Referencing of Cup Orientation in Total Hip Arthroplasty , 2005, Clinical orthopaedics and related research.