Free cholesterol fiber-optic biosensor for serum samples with simplex optimization.

An optical fiber biosensor for free cholesterol monitoring in serum samples is described. Silicone-entrapped tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) complex, the luminescence of which is sensitive to oxygen changes, is used as an optical transducer of the oxidation of cholesterol by cholesterol oxidase. The biocatalyst is entrapped in a graphite powder layer deposited onto the dyed silicone film. Optimization of some interdependent chemical variables which affect the performance of the biosensor has been achieved by application of a super-modified simplex method. The dynamic range of the biosensing membranes is found to be 0.15-3.0 mM of free cholesterol. Studies of the reproducibility, stability and interferences of the device, as well as the application of the sensor to measurements in serum samples, are reported. Simplex optimization has proven to be a very useful tool in the search for the optimal conditions for performing analyses with the optical fiber biosensor.

[1]  R. Kellner,et al.  Flow-injection analysis for total cholesterol with photometric detection , 1994 .

[2]  S. Deming,et al.  Simplex optimization of analytical chemical methods , 1974 .

[3]  John P. Hart,et al.  Fabrication and characterization of a screen-printed, disposable, amperometric cholesterol biosensor , 1994 .

[4]  P. Fu,et al.  Enzymatic determination of total serum cholesterol. , 1974, Clinical chemistry.

[5]  A. L. Crumbliss,et al.  A carrageenan hydrogel stabilized colloidal gold multi-enzyme biosensor electrode utilizing immobilized horseradish peroxidase and cholesterol oxidase/cholesterol esterase to detect cholesterol in serum and whole blood. , 1993, Biosensors & bioelectronics.

[6]  M. Valcárcel,et al.  Determination of total cholesterol in serum by flow injection analysis with immobilized enzymes. , 1987, Clinica chimica acta; international journal of clinical chemistry.

[7]  O S Wolfbeis,et al.  Optical sensors. Part 34. Fibre optic glucose biosensor with an oxygen optrode as the transducer. , 1988, The Analyst.

[8]  G. Guilbault,et al.  Fluorometric enzymatic determination of total cholesterol in serum. , 1975, Clinical chemistry.

[9]  A. Turner,et al.  An Organic Phase Enzyme Electrode for Cholesterol , 1991 .

[10]  M. E. Díaz-García,et al.  Enzymic Reactor/Room-Temperature Phosphorescence Sensor System for Cholesterol Determination in Organic Solvents , 1994 .

[11]  Miguel de la Guardia,et al.  Enzymic flow injection analysis in nonaqueous media , 1992 .

[12]  G. Guilbault,et al.  Enzyme-based fiber-optic device for the determination of total and free cholesterol , 1992 .

[13]  S. Dong,et al.  Cholesterol sensor based on electrodeposition of catalytic palladium particles , 1993 .

[14]  O. Wolfbeis,et al.  A fiberoptic cholesterol biosensor with an oxygen optrode as the transducer. , 1990, Analytical biochemistry.

[15]  T. Cleland,et al.  Temperature enhanced chemiluminescence for determination of cholesterol , 1992 .

[16]  H. Seco-Lago,et al.  Application of Derivative Spectrophotometry to Simultaneous Determination of Nickel and Mercury with Diethylenetriaminepentaacetic Acid (DTPA) , 1997 .

[17]  M. Mascini,et al.  Cholesterol biosensors prepared by electropolymerization of pyrrole , 1993 .

[18]  Guillermo Orellana,et al.  Oxygen-sensitive layers for optical fibre devices , 1995 .

[19]  A. Noma,et al.  Polarographic method for rapid microdetermination of cholesterol with cholesterol esterase and cholesterol oxidase. , 1976, Clinical chemistry.

[20]  Y. Hayashi,et al.  Determination of cholesterol with a laboratory-built chemiluminescence system , 1986 .

[21]  A. Townshend,et al.  Determination of cholesterol by flow injection analysis with immobilized cholesterol oxidase , 1985 .

[22]  K. Hasebe,et al.  Differential pulse polarographic determination of some carcinogenic nitrosamines. , 1975, Analytical chemistry.

[23]  L R Faulkner,et al.  Determination of cholesterol and cholesterol ester with novel enzyme microsensors. , 1993, Analytical chemistry.

[24]  T. Yao,et al.  Amperometric flow-injection determination of glucose, urate and cholesterol and blood serum by using some immobilized enzyme reactors and a poly(1,2-diaminobenzene)-coated platinum electrode , 1994 .

[25]  B. Zak,et al.  Some observations on cholesterol measurement in the clinical laboratory , 1990 .

[26]  Pierre R. Coulet,et al.  Chemiluminescent Analyte Microdetection Based on the Luminol-H2 O 2 Reaction Using Peroxidase Immobilized on New Synthetic Membranes , 1987 .

[27]  Jaromir Ruzicka,et al.  Enzymatic Assay by Flow Injection Analysis with Detection by Chemiluminescence: Determination of Glucose, Creatinine, Free Cholesterol and Lactic Acid Using an Integrated Fia Microconduit , 1986 .

[28]  I. Karube,et al.  Amperometric determination of total cholesterol in serum with use of immobilized cholesterol esterase and cholesterol oxidase , 1982 .

[29]  N. Tietz Fundamentals of Clinical Chemistry , 1970 .