Straight-Forward versus Bicortical Fixation Penetrating Endplate in Lumbosacral Fixation-A Biomechanical Study

Objective Many lumbosacral fixation techniques have been described to offer a more screw-bone purchase. The forward anatomical fixation parallel to the endplate is still the most preferred method. Literature revealed little knowledge regarding the mechanical stability of lumbosacral trans-endplate fixation compared to the traditional trans-pedicular screw fixation method. The aim of this study is to assess the pull-out strength of lumbosacral screws penetrating the end plate and comparing it to the conventional trans-pedicular screw insertion method. Methods Eight lumbar and eight sacral vertebrae, with average age 69.4 years, Left pedicles of the 5th lumbar vertebrae were used for trans-endplate screw fixation, group 1A, right pedicles were used for anatomical trans-pedicular screw fixation, group 1B. In the sacral vertebrae, the right side S1 pedicles were used for trans-endplate fixation, group 2A, left side pedicles were used for anatomical trans-pedicular screw fixation, group 2B. The biomechanical tests were performed using the axial compression testing machine. All tests were applied using 2 mm/min traction speed. Results The average pull-out strength values of groups 1A and 1B were 403.78±11.71 N and 306.26±17.55 N, respectively. A statistical significance was detected with p=0.012. The average pull-out strength values of groups 2A and 2B were 388.73±17.03 N and 299.84±17.52 N, respectively. A statistical significance was detected with p=0.012. Conclusion The trans-endplate lumbosacral fixation method is a trustable fixation method with a stronger screw-bone purchase and offer a good alternative for surgeons specially in patients with osteoporosis.

[1]  M. H. Ozcanhan,et al.  The Mechanical Effect of Rod Contouring on Rod-Screw System Strength in Spine Fixation , 2016, Journal of Korean Neurosurgical Society.

[2]  R. Gazzeri Percutaneous Pedicle Screw Fixation Technique in the Thoracic and Lumbar Spine-Tips and Tricks. , 2016, Surgical technology international.

[3]  D. Bader,et al.  The Effect of Transpedicular Screw Design on Its Performance in Vertebral Bone Under Tensile Loads: A Parametric Study , 2013, Clinical spine surgery.

[4]  A. Karaarslan,et al.  Are pedicular screws and lateral hook screws more resistant against pullout than conventional spinal hooks and screws in terminal vertebral segment fixation? , 2016, Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery.

[5]  T. Asazuma,et al.  Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique: technical note. , 2014, Journal of neurosurgery. Spine.

[6]  N. Ebraheim,et al.  Surgical anatomy of the sacrum. , 2008, American journal of orthopedics.

[7]  T. Steffen,et al.  Double Pedicle Screw Instrumentation in the Osteoporotic Spine: A Biomechanical Feasibility Study , 2007, Journal of spinal disorders & techniques.

[8]  L. Claes,et al.  Biomechanical performance of the new BeadEx implant in the treatment of osteoporotic vertebral body compression fractures: restoration and maintenance of height and stability. , 2006, Clinical biomechanics.

[9]  K. Luk,et al.  A Stronger Bicortical Sacral Pedicle Screw Fixation Through The S1 Endplate: An In Vitro Cyclic Loading and Pull-Out Force Evaluation , 2005, Spine.

[10]  S. Cook,et al.  Biomechanical study of pedicle screw fixation in severely osteoporotic bone. , 2004, The spine journal : official journal of the North American Spine Society.

[11]  G. Andersson,et al.  Augmentation of Pedicle Screw Fixation Strength Using an Injectable Calcium Phosphate Cement as a Function of Injection Timing and Method , 2004, Spine.

[12]  J. Leong,et al.  Variation in Bone Mineral Density of the Sacrum in Young Adults and Its Significance for Sacral Fixation , 2000, Spine.

[13]  R. Delamarter Principles and Techniques of Spine Surgery , 1998 .

[14]  J. Leong,et al.  Comparison of the Strengths of Lumbosacral Fixation Achieved With Techniques Using One and Two Triangulated Sacral Screws , 1998, Spine.

[15]  T. Washio,et al.  Structural Characteristics of the Pedicle and Its Role in Screw Stability , 1997, Spine.

[16]  B. Cunningham,et al.  Static and Cyclical Biomechanical Analysis of Pedicle Screw Spinal Constructs , 1993, Spine.

[17]  L. Ross,et al.  Pitfalls of Pedicle Screw Fixation in the Sacrum: A Cadaver Model , 1992, Spine.

[18]  S. Garfin,et al.  Screw Fixation in the Human Sacrum: An In Vitro Study of the Biomechanics of Fixation , 1992, Spine.

[19]  W. Rauschning,et al.  Surgical Anatomy of the Sacrum: A Guide for Rational Screw Fixation , 1991, Spine.

[20]  J. Massie,et al.  Anatomic Consideration for Sacral Screw Placement , 1991, Spine.

[21]  R. Winter,et al.  Fusion to the Sacrum for Nonparalytic Scoliosis in the Adult , 1986, Spine.

[22]  M. Schendel,et al.  Comparison of lumbosacral fixation devices. , 1986, Clinical orthopaedics and related research.