Biochemical oxygen demand sensor using Serratia marcescens LSY 4.

A microbial biochemical oxygen demand (BOD) sensor consisting of Serratia marcescens LSY 4 and an oxygen electrode was prepared for estimation of the biochemical oxygen demand. The response of the BOD sensor was insensitive to pH in the range of pH 6.0-8.0, and the baseline drift of the signal was nearly absent even in unbuffered aqueous solution. Because heavy metal ions were precipitated from the phosphate buffer solution, unbuffered solution was used to investigate the effect of the concentration of heavy metal ions on the sensor response. Contrary to previous studies, not only Cu2+ and Ag+ but also Cd2+ and Zn2+ significantly decreased the response of the BOD sensor in unbuffered solution. Graft polymerization of sodium styrene sulfonate on the surface of the porous teflon membrane was carried out to absorb the heavy metal ions permeating through the membrane. Tolerance against Zn2+ was induced for S. marcescens LSY 4 to make the cells less sensitive to the presence of heavy metal ions. The membrane modification and the Zn2+ tolerance induction showed some positive effects in such a way that they reduced the inhibitory effects of Zn2+ and Cd2+ on the sensitivity of the BOD sensor. However, they had no effect on the protection of the cells against the interference of Cu2+ and Ag+ on the performance of the sensor.

[1]  I. Karube,et al.  Disposable sensor for biochemical oxygen demand , 1996, Applied Microbiology and Biotechnology.

[2]  I. Karube,et al.  Biochemical fuel cell utilizing immobilized cells of clostridium butyricum , 1977 .

[3]  Fujio Takahashi,et al.  BOD sensor using magnetic activated sludge , 1995 .

[4]  Hirohisa Tanaka,et al.  BOD BIOSENSOR FOR SECONDARY EFFLUENT FROM WASTEWATER TREATMENT PLANTS , 1994 .

[5]  E Tamiya,et al.  A novel BOD sensor based on bacterial luminescence , 1993, Biotechnology and bioengineering.

[6]  I Karube,et al.  Microbial electrode BOD sensors , 1977, Biotechnology and bioengineering.

[7]  J. Chu,et al.  Study of BOD Microbial Sensors for Waste Water Treatment Control , 1991, Applied biochemistry and biotechnology.

[8]  T. Tan,et al.  Monitoring BOD in the presence of heavy metal ions using a poly(4-vinylpyridine)-coated microbial sensor , 1994 .

[9]  T. Tan,et al.  Effect of heavy netal ions on the efficacy of a mixed Bacili BOD sensor , 1994 .

[10]  E. Galindo,et al.  Characterization of microbial membranes used for the estimation of biochemical oxygen demand with a biosensor , 1992 .

[11]  S. Brookman,et al.  Estimation of biochemical oxygen demand in slurry and effluents using ultra-violet spectrophotometry , 1997 .

[12]  Sheela Berchmans,et al.  Torulopsis candida based sensor for the estimation of biochemical oxygen demand and its evaluation , 1996 .

[13]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[14]  P Ott,et al.  A microbial sensor for BOD , 1990 .

[15]  W. M. Haynes CRC Handbook of Chemistry and Physics , 1990 .

[16]  J. Marty,et al.  Measurement of BOD: Correlation Between 5-Day BOD and Commercial BOD Biosensor Values , 1997 .

[17]  Z. Qian,et al.  Dead Bacillus subtilis cells for sensing biochemical oxygen demand of waters and wastewaters , 1997 .