Photogrammetric measurement of initial tooth displacement under tensile force.

The purpose of this study was to quantitatively measure tooth displacement under low horizontal tensile force (≤18 N) and to test the reproducibility of measurements. Anterior tooth mobility was measured using a photogrammetric measurement technique in 23 periodontally healthy subjects. While slowly increasing the tension on each tooth, an automated software program recorded three-dimensional tooth displacement at 3 N intervals, up to 18 N. Measurements were repeated three-times for each tooth. The vector of absolute tooth mobility in the buccal direction was calculated. Intra-class correlations of the three repeated measurements of each tooth were calculated and ranged between "good" and "optimal". The agreement of measurements was significant (p≤0.05). The analysis of differences between the deviation vectors of contralateral teeth revealed that most differences emerged to be statistically non-significant. The combination of a mechanical loading approach with the optoelectronic system allowed the measurement of three-dimensional tooth mobility in vivo.

[1]  N. Yoshida,et al.  A new method for qualitative and quantitative evaluation of tooth displacement under the application of orthodontic forces using magnetic sensors. , 2000, Medical engineering & physics.

[2]  S. Holst,et al.  The effect of provisional restoration type on micromovement of implants. , 2008, The Journal of prosthetic dentistry.

[3]  J. Bortz Statistik für Human- und Sozialwissenschaftler , 2010 .

[4]  B. Melsen,et al.  Tooth displacement analysed on human autopsy material by means of a strain gauge technique. , 1991, European journal of orthodontics.

[5]  E. Tanaka,et al.  In vivo measurement of the elastic modulus of the human periodontal ligament. , 2001, Medical engineering & physics.

[6]  Arturo N Natali,et al.  Numerical analysis of tooth mobility: formulation of a non-linear constitutive law for the periodontal ligament. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[7]  H. Mühlemann Tooth Mobility*: The Measuring Method. Initial and Secondary Tooth Mobility , 1954 .

[8]  Hans R. Mühlemann,et al.  Tooth Mobility (III): The Mechanism of Tooth Mobility , 1954 .

[9]  P Vacher,et al.  Optical analysis of displacement and strain fields on human skin , 2001, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[10]  S. Holst,et al.  Noncontact intraoral measurement of force-related tooth mobility , 2010, Clinical Oral Investigations.

[11]  I. Grabec,et al.  Statistical modeling of tooth mobility after treating adult periodontitis , 2002, Clinical Oral Investigations.

[12]  John Botsis,et al.  In vitro time-dependent response of periodontal ligament to mechanical loading. , 2005, Journal of applied physiology.

[13]  Marjolein van der Glas,et al.  Towards computer-assisted surgery in shoulder joint replacement , 2002 .

[14]  J. Castracane,et al.  Evaluation of orbital stress dissipation in pediatric and adult skulls using electronic speckle pattern interferometry. , 1999, Archives of otolaryngology--head & neck surgery.

[15]  G. J. Parfitt The Dynamics of a Tooth in Function , 1961 .

[16]  D Drescher,et al.  In vitro analysis of the initial tooth mobility in a novel optomechanical set-up. , 1998, Medical engineering & physics.

[17]  C Bourauel,et al.  Experimental and numerical determination of initial tooth mobility and material properties of the periodontal ligament in rat molar specimens. , 2003, European journal of orthodontics.

[18]  Hans R. Mühlemann,et al.  10 Years of Tooth‐Mobility Measurements , 1960 .

[19]  C. Klöckner,et al.  Oberflächenvermessung des Rückens , 2000, Der Orthopäde.

[20]  P Castellini,et al.  Teeth mobility measurement: a laser vibrometry approach. , 1998, Journal of clinical laser medicine & surgery.

[21]  J. Shelton,et al.  Laser speckle photography to measure surface displacements on cortical bone--verification of an automated analysis system. , 1998, Medical engineering & physics.

[22]  Stuart Robson,et al.  Close Range Photogrammetry , 2007 .

[23]  P. Burke,et al.  Stereophotographic measurement of change in facial soft tissue morphology following surgery. , 1983, The British journal of oral surgery.

[24]  C Klöckner,et al.  [Measuring the surface of the back. Value in diagnosis of spinal diseases]. , 2000, Der Orthopade.

[25]  Christoph Bourauel,et al.  Determination of the Elasticity Parameters of the Human Periodontal Ligament and the Location of the Center of Resistance of Single-rooted Teeth A Study of Autopsy Specimens and Their Conversion into Finite Element Models , 2002, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie.

[26]  H. L. Mitchell,et al.  Medical photogrammetric measurement: overview and prospects , 2002 .

[27]  A Asundi,et al.  Analysis on the nature of thermally induced deformation in human dentine by electronic speckle pattern interferometry (ESPI). , 2001, Journal of dentistry.

[28]  John Tyson,et al.  Pull-field dynamic displacement and strain measurement using advanced 3D image correlation photogrammetry: Part 1 , 2003 .

[29]  V Moreno,et al.  In-plane electronic speckle pattern of interference (ESPI) with optical fibre system applied to the study of the human jaw. , 2004, Medical engineering & physics.

[30]  John Tyson,et al.  Biomechanics deformation and strain measurements with 3D image correlation photogrammetry , 2002 .

[31]  D. Arola,et al.  Applications of digital image correlation to biological tissues. , 2004, Journal of biomedical optics.

[32]  J. Shelton,et al.  Laser interferometric techniques in orthopaedics. , 1991, Journal of medical engineering & technology.

[33]  Markus B Blatz,et al.  Influence of impression material and time on the 3-dimensional accuracy of implant impressions. , 2007, Quintessence international.

[34]  E. Lehmann,et al.  Nonparametrics: Statistical Methods Based on Ranks , 1976 .

[35]  T. C. Chu,et al.  Three-dimensional displacement measurements using digital image correlation and photogrammic analysis , 1990 .

[36]  Körber Kh Electronic registration of tooth movements. , 1971 .

[37]  G. Vendroux,et al.  Submicron deformation field measurements: Part 2. Improved digital image correlation , 1998 .