Is high sensitivity always desirable for a grating-based differential phase contrast imaging system?

PURPOSE In grating-based x-ray differential phase contrast (DPC) imaging, the measured signal amplitude of the phase shift induced by an image object is proportional to the so-called system sensitivity. Therefore, to achieve a better signal-to-noise (SNR) for improved imaging performance, it is generally believed that one should increase the system sensitivity by reducing the period of the analyzer grating or increasing the distance between the phase grating and analyzer grating. The purpose of this work is to theoretically and experimentally demonstrate that there is an optimal system sensitivity to attain the highest SNR for a given task provided that the standard phase-stepping acquisition and phase retrieval methods are used. When system sensitivity goes beyond this optimal value, SNR decreases and the imaging performance deteriorates. METHODS Due to the fundamental fact that the measured phase signal is a cyclic variable, the phase wrapping effect is inevitable in DPC imaging when the system sensitivity increases. The phase wrapping effect appears in both signal and noise measurements. The effect in the signal measurement is manifested in the so-called signal statistical bias and such effect often impacts the accuracy of the measurement. The phase wrapping effect also appears in the noise variance measurement and impacts the precision of the measurement. A thorough theoretical analysis was performed in this work to demonstrate the quantitative impacts of phase wrapping on both signal bias and noise variance and thus on the actual system SNR. The joint effect of phase wrapping in both the signal bias and noise variance yields an optimal system sensitivity to achieve the highest SNR. Both extensive numerical simulation studies and experimental studies were performed to validate the theoretical analysis. RESULTS Both theoretical analysis and experimental studies show that the SNR of the DPC signal is not always proportional to the sensitivity due to the cyclic nature of the signal and the phase wrapping effect. For a given refraction angle and exposure level, there exists an optimal sensitivity factor that maximizes the SNR, beyond which, increasing the sensitivity will decrease the SNR. CONCLUSIONS Increase of system sensitivity does not always improve x-ray DPC imaging performance provided that the standard phase-stepping acquisition and phase retrieval methods are used.

[1]  Andreas Fehringer,et al.  Grating-based phase-contrast and dark-field computed tomography: a single-shot method , 2017, Scientific Reports.

[2]  Guang-Hong Chen,et al.  Studies of signal estimation bias in grating‐based x‐ray multicontrast imaging , 2017, Medical physics.

[3]  Franz Pfeiffer,et al.  Experimental Realisation of High-sensitivity Laboratory X-ray Grating-based Phase-contrast Computed Tomography , 2016, Scientific Reports.

[4]  Franz Pfeiffer,et al.  Low-dose, phase-contrast mammography with high signal-to-noise ratio. , 2016, Biomedical optics express.

[5]  Franz Pfeiffer,et al.  Penalized maximum likelihood reconstruction for x-ray differential phase-contrast tomography. , 2015, Medical physics.

[6]  Han Wen,et al.  Enhancing Tabletop X-Ray Phase Contrast Imaging with Nano-Fabrication , 2015, Scientific reports.

[7]  Gerhard Martens,et al.  Slit-scanning differential x-ray phase-contrast mammography: proof-of-concept experimental studies. , 2015, Medical physics.

[8]  Franz Pfeiffer,et al.  Phase Unwrapping in Spectral X-Ray Differential Phase-Contrast Imaging With an Energy-Resolving Photon-Counting Pixel Detector , 2015, IEEE Transactions on Medical Imaging.

[9]  Ke Li,et al.  Anatomical background noise power spectrum in differential phase contrast and dark field contrast mammograms. , 2014, Medical physics.

[10]  Ke Li,et al.  Grating based x-ray differential phase contrast imaging without mechanical phase stepping. , 2014, Optics express.

[11]  R. Ivkov,et al.  CORRIGENDUM: Effect of magnetic dipolar interactions on nanoparticle heating efficiency: Implications for cancer hyperthermia , 2014, Scientific Reports.

[12]  Guang-Hong Chen,et al.  Grating-based phase contrast tomosynthesis imaging: proof-of-concept experimental studies. , 2013, Medical physics.

[13]  M. Strobl General solution for quantitative dark-field contrast imaging with grating interferometers , 2013, Scientific Reports.

[14]  P Thibault,et al.  Unwrapping differential x-ray phase-contrast images through phase estimation from multiple energy data. , 2013, Optics express.

[15]  Franz Pfeiffer,et al.  Experimental results from a preclinical X-ray phase-contrast CT scanner , 2012, Proceedings of the National Academy of Sciences.

[16]  Rainer Raupach,et al.  Performance evaluation of x-ray differential phase contrast computed tomography (PCT) with respect to medical imaging. , 2012, Medical physics.

[17]  Guang-Hong Chen,et al.  Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping. , 2011, Medical physics.

[18]  C. David,et al.  The First Analysis and Clinical Evaluation of Native Breast Tissue Using Differential Phase-Contrast Mammography , 2011, Investigative radiology.

[19]  Dan Stutman,et al.  Talbot phase-contrast x-ray imaging for the small joints of the hand , 2011, Physics in medicine and biology.

[20]  Ashley F. Stein,et al.  Interpretation of dark-field contrast and particle-size selectivity in grating interferometers. , 2011, Applied optics.

[21]  Thilo Michel,et al.  Noise in x-ray grating-based phase-contrast imaging. , 2011, Medical physics.

[22]  Rainer Raupach,et al.  Analytical evaluation of the signal and noise propagation in x-ray differential phase-contrast computed tomography , 2011, Physics in medicine and biology.

[23]  Ke Li,et al.  Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography. , 2010, Medical physics.

[24]  Ziyu Wu,et al.  Low-dose, simple, and fast grating-based X-ray phase-contrast imaging , 2010, Proceedings of the National Academy of Sciences.

[25]  Franz Pfeiffer,et al.  Inverse geometry for grating-based x-ray phase-contrast imaging , 2009 .

[26]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[27]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[28]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[29]  Atsushi Momose,et al.  Demonstration of X-Ray Talbot Interferometry , 2003 .

[30]  Antonio Baldi Phase unwrapping by region growing. , 2003, Applied optics.

[31]  C. W. Chen,et al.  Two-dimensional phase unwrapping with use of statistical models for cost functions in nonlinear optimization. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[32]  Mihai Datcu,et al.  Bayesian approaches to phase unwrapping: theoretical study , 2000, IEEE Trans. Signal Process..