Standard Drug Concentrations and Smart-Pump Technology Reduce Continuous-Medication-Infusion Errors in Pediatric Patients

Objective. To determine if combining standard drug concentrations with “smart-pump” technology reduces reported medication-infusion errors. Design. Preintervention and postintervention comparison of reported medication errors related to infusion therapies during the calendar years 2002 and 2003. Setting. A 242-bed university-affiliated tertiary pediatric hospital. Intervention. Change in continuous-medication-infusion process, comprising the adoption of (1) standard drug concentrations, (2) “smart” syringe pumps, and (3) human-engineered medication labels. Main Outcome Measures. Comparison of reported continuous-medication-infusion errors before and after the intervention. Results. The number of reported errors dropped by 73% for an absolute risk reduction of 3.1 to 0.8 per 1000 doses. Preparation errors that occurred in the pharmacy decreased from 0.66 to 0.16 per 1000 doses; the number of 10-fold errors in dosage decreased from 0.41 to 0.08 per 1000 doses. Conclusions. The use of standard drug concentrations, smart syringe pumps, and user-friendly labels reduces reported errors associated with continuous medication infusions. Standard drug concentrations can be chosen to allow most neonates to receive needed medications without concerns related to excess fluid administration.

[1]  D. Bates,et al.  Medication errors and adverse drug events in pediatric inpatients. , 2001, JAMA.

[2]  C. Fernandez,et al.  Strategies for the prevention of medical error in pediatrics. , 2003, The Journal of pediatrics.

[3]  W. Benitz,et al.  Medication errors in children. , 2001, JAMA.

[4]  G. Koren,et al.  Discrepancies between ordered and delivered concentrations of opiate infusions in critical care , 2003, Critical care medicine.

[5]  McLeroy Pa The rule of six: calculating intravenous infusions in a pediatric crisis situation. , 1994 .

[6]  Infusion Safety: Addressing Harm with High-Risk Drug Administration , 2004 .

[7]  D. Bates,et al.  Preventable adverse drug events in hospitalized patients: a comparative study of intensive care and general care units. , 1997, Critical care medicine.

[8]  T S Lesar,et al.  Errors in the use of medication dosage equations. , 1998, Archives of pediatrics & adolescent medicine.

[9]  P A McLeroy The rule of six: calculating intravenous infusions in a pediatric crisis situation. , 1994, Hospital pharmacy.

[10]  Colleen M. Malashock,et al.  Effect of Smart Infusion Pumps on Medication Errors Related to Infusion Device Programming , 2004 .

[11]  M. Apkon,et al.  Design of a safer approach to intravenous drug infusions: failure mode effects analysis , 2004, Quality and Safety in Health Care.

[12]  A B Smith,et al.  Medication error reporting: a survey of nursing staff. , 2000, Journal of nursing care quality.

[13]  T. Lesar,et al.  A Standardized Approach to Pediatric Parenteral Medication Delivery , 2004 .

[14]  David W Bates,et al.  Medication errors observed in 36 health care facilities. , 2002, Archives of internal medicine.

[15]  T. Lesar,et al.  Systematic steps to diminish multi-fold medication errors in neonates. , 2003, The Journal of Pediatric Pharmacology and Therapeutics.