Monitoring of stress distribution along a ground anchor using BOTDA

For the understanding of the bearing behavior of a loaded ground anchor, the measuring and monitoring of the stress distribution in the anchor tendon is essential. This paper proposes a novel monitoring ground anchor using embedded optical fibers for the continuous strain assessment along the anchor tendon. In a first step, optical sensors have been integrated into short tendons using different methods and laboratory strain testing was performed on these instrumented tendons. The evaluation of the laboratory testing enabled the design and development of an 8m long monitoring ground anchor for field application. In 2009, this anchor has been placed into a wall supporting an excavation pit and subsequently, anchor pullout test was carried out. The anchor was loaded stepwise up to 470kN, almost reaching its ultimate bearing capacity. Optical measurements were taken successfully at each load step. Comparison of the optical data with data acquired using conventional methods indicated good consistency of the results. To a geotechnical engineer, this proposed monitoring anchor provides a powerful tool for the measuring of the pullout load, the anchor head displacement and the load distribution in the anchor tendon.

[1]  Luc Thevenaz,et al.  Simple distributed temperature sensor based on Brillouin gain spectrum analysis , 1994, Other Conferences.

[2]  Michael Iten,et al.  Defining and monitoring of landslide boundaries using fiber optic systems , 2009 .

[3]  BOTDA road-embedded strain sensing system for landslide boundary localization , 2009, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[4]  Anthony D. Barley,et al.  Recent Advances In Ground Anchor And Ground Reinforcement Technology With Reference To The Development Of The Art , 2000 .

[5]  Brahim Benmokrane,et al.  Design and Evaluation of Fiber-Reinforced Polymer Bond-Type Anchorages and Ground Anchors , 2006 .

[6]  Alexander M. Puzrin,et al.  Study of a progressive failure in soil using BEDS , 2009, International Conference on Optical Fibre Sensors.

[7]  Ri Woods,et al.  The influence of bond stress distribution on ground anchor design , 1997 .

[8]  H Schnabel,et al.  Load Transfer in Pressure Injected Anchors , 1978 .

[9]  Wolfgang R. HABEL Assessment of Structures using Fibre-optic Sensors(Diagnose des Bauwerkverhaltens mittels faseroptischer Sensorik) , .

[10]  Nicola Moraci,et al.  Factors affecting the pullout behaviour of extruded geogrids embedded in a compacted granular soil , 2006 .

[11]  M. Kusabuka,et al.  A method to predict the load-displacement relationship of ground anchors , 1978 .

[12]  Brahim Benmokrane,et al.  MONITORING BEHAVIOR OF GROUTED ANCHORS USING VIBRATING-WIRE GAUGES , 1995 .

[13]  Petros P. Xanthakos,et al.  Ground anchors and anchored structures , 1991 .