A New Calibration Method for Piezoelectric Testing System Based on Orthogonal Calibration Method

The accuracy of piezoelectric test system has a direct influence on the accuracy of the vector force detection. Piezoelectric sensor parameters are obtained by calibration system calibrated through orthogonal calibration method. Accuracy of the application of field test lacks the corresponding theoretical basis, resulting in test system test accuracy is questioned. In this paper, piezoelectric force test system is used as the research object. In order to verify accuracy of piezoelectric test system through calibration of orthogonal calibration method, a variable angle deflection loading device was designed. An incremental calibration method for thrust test is put forward by applying vector force at different angles. Based on vector force coordinate transformation matrix, a deflection load test and analysis model are established. The vector force coordinates transformation matrix is used to calculate the experimental data obtained from the deviation angle test system, and the deviation of the vector force value is obtained. Finally, the accuracy, effectiveness and rationality of piezoelectric test system through the orthogonal calibration method are verified.

[1]  Xue Yang,et al.  Research on static decoupling algorithm for piezoelectric six axis force/torque sensor based on LSSVR fusion algorithm , 2018 .

[2]  Wei Liu,et al.  A novel calibration method based on Kirchhoff theory for piezoelectric dynamometer , 2017 .

[3]  Marko Miloš,et al.  A novel 6 DOF thrust vector control test stand , 2015 .

[4]  Hong Liu,et al.  Design and optimization of a novel six-axis force/torque sensor for space robot , 2015 .

[5]  Ann M. Wright,et al.  A six degree-of-freedom thrust sensor for a labscale hybrid rocket , 2013 .

[6]  Min Yang The Calibration Method of a Large Six-Axis Force Sensors , 2013 .

[7]  Ping Cai,et al.  Decoupling Analysis of a Sliding Structure Six-axis Force/Torque Sensor , 2013 .

[8]  Heikki Haario,et al.  Novel Online Re-Calibration Method for Multi-Axis Force/Torque Sensor of ITER Welding/Machining Robot , 2013, IEEE Sensors Journal.

[9]  Jack T Dennerlein,et al.  A force plate based method for the calibration of force/torque sensors. , 2012, Journal of biomechanics.

[10]  Jun Zhang,et al.  Design, calibration and error analysis of a piezoelectric thrust dynamometer for small thrust liquid pulsed rocket engines , 2011 .

[11]  Wei Liu,et al.  Research on parallel load sharing principle of piezoelectric six-dimensional heavy force/torque sensor , 2011 .

[12]  Zhu Changchun Neural Network Hybrid Modeling Method For Transducer Calibration , 2010 .

[13]  Shilin Xie Neural Network Hybrid Modeling Method For Transducer Calibration , 2010 .

[14]  Angelo Cappello,et al.  A portable system for in-situ re-calibration of force platforms: experimental validation. , 2009, Gait & posture.

[15]  Angelo Cappello,et al.  A portable system for in-situ re-calibration of force platforms: theoretical validation. , 2008, Gait & posture.

[16]  Hiranmay Saha,et al.  Temperature compensation of piezoresistive micro-machined porous silicon pressure sensor by ANN , 2006, Microelectron. Reliab..